Voltammetric sensing performances of a carbon ionic liquid electrode modified with black phosphorene and hemin

被引:28
|
作者
Li, Xiaoyan [1 ]
Luo, Guiling [1 ]
Xie, Hui [1 ]
Niu, Yanyan [1 ]
Li, Xiaobao [1 ]
Zou, Ruyi [1 ]
Xi, Yaru [1 ]
Xiong, Yi [1 ]
Sun, Wei [1 ]
Li, Guangjiu [2 ]
机构
[1] Hainan Normal Univ, Coll Chem & Chem Engn, Key Lab Funct Mat & Photoelectrochem Haikou, Key Lab Laser Technol & Optoelect Funct Mat Haina, Haikou 571158, Hainan, Peoples R China
[2] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Minist Educ, Key Lab Opt Elect Sensing & Analyt Chem Life Sci, Qingdao 266042, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
Black phosphorene; Hemin; Electrochemical biosensor; Electrocatalytic effect; Poly(3; 4-ethylenedioxythiophene)-poly(styrenesulfonate); Carbon ionic liquid electrode; Direct electrochemistry; Trichloroacetic acid; Nitrite; Hydrogen peroxide; NANOCOMPOSITE MODIFIED ELECTRODE; DIRECT ELECTROCHEMISTRY; HORSERADISH-PEROXIDASE; GRAPHENE OXIDE; ELECTROCATALYSIS; MYOGLOBIN; HEMOGLOBIN; BIOSENSOR; TRANSISTORS; FILM;
D O I
10.1007/s00604-019-3421-x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A black phosphorene (BPE) and poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) hybrid was used for the immobilization of hemin on acarbon ionic liquid electrode (CILE). BPE inside thePEDOT:PSS film was stable without adverse effects of water and oxygen. The hemin-modified electrode facilitates electrochemical communication with a couple of well-shaped and enhanced redox waves. Therefore BPE exhibits an accelerating function to the electron movement. This sensor exhibits excellent electrocatalytic effects on the reduction of various substrates including trichloroacetic acid (TCA), nitrite and H2O2. As for TCA, the reduction current at -0.36V (vs. Ag/AgCl) increases linearly in the concentrationrange from 2.0 to 180mmolL(-1) with a detection limit of 0.67mmolL(-1) (at 3 sigma). As for nitrite, the reduction current at -0.59Vis linear in the1.0 to 10.5mmolL(-1) concentration range,and the detection limit is 0.33mmolL(-1) (at 3 sigma). As for H2O2, the reduction current at -0.033V (vs. Ag/AgCl) is linear in the concentration rangefrom 4.0 to 35.0mmolL(-1) and the detection limit is 1.3mmolL(-1) (at 3 sigma). The real sample was analyzed with satisfactory results, which indicated that BPE had potential applications in the field of electrochemical biosensor.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Voltammetric Determination of Ceftizoxime by a Carbon Paste Electrode Modified with Ionic Liquid and Cu (Him)2 Nanoparticles
    Tajik, Somayeh
    Beitollahi, Hadi
    Shahsavari, Mahboobeh
    Sheikhshoaie, Iran
    TOPICS IN CATALYSIS, 2022, 65 (5-6) : 595 - 603
  • [22] Sensitive Voltammetric Detection of Metol with a TiO2 Nanowire Modified Carbon Ionic Liquid Electrode
    Niu, Xueliang
    Yan, Lijun
    Li, Xiaobao
    Hu, Anhui
    Zheng, Caijuan
    Zhang, Yiliang
    Sun, Wei
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (02): : 1720 - 1729
  • [23] A graphene modified carbon ionic liquid electrode for voltammetric analysis of the sequence of the Staphylococcus aureus nuc gene
    Niu, Xueliang
    Chen, Wei
    Wang, Xiuli
    Men, Yongling
    Wang, Qin
    Sun, Wei
    Li, Guangjiu
    MICROCHIMICA ACTA, 2018, 185 (03)
  • [24] NiO/CNTs Nanocomposite Modified Ionic Liquid Carbon Paste Electrode as a Voltammetric Sensor for Determination of Quercetin
    Gupta, Vinod Kumar
    Golestani, Fereshteh
    Ahmadzadeh, Saeid
    Karimi-Maleh, Hassan
    Fazli, Gozal
    Khosravi, Sahebe
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (04): : 3657 - 3667
  • [25] A modified carbon paste electrode with N-rGO/CuO nanocomposite and ionic liquid for the efficient and cheap voltammetric sensing of hydroquinone in water specimens
    Jahani, Peyman Mohammadzadeh
    Nejad, Fariba Garkani
    Dourandish, Zahra
    Zarandi, Mostafa Poursoltani
    Safizadeh, Mohammad Mahdi
    Tajik, Somayeh
    Beitollahi, Hadi
    CHEMOSPHERE, 2022, 302
  • [26] Sensitive Voltammetric Determination of Ethinyl Estradiol on Carbon Black Modified Electrode
    Smajdor, Joanna
    Piech, Robert
    Piek, Magdalena
    Paczosa-Bator, Beata
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (13) : H885 - H889
  • [27] Voltammetric sensing of thallium at a carbon paste electrode modified with a crown ether
    Cheraghi, Somayye
    Taher, Mohammad Ali
    Fazelirad, Hamid
    MICROCHIMICA ACTA, 2013, 180 (11-12) : 1157 - 1163
  • [28] Voltammetric sensing of thallium at a carbon paste electrode modified with a crown ether
    Somayye Cheraghi
    Mohammad Ali Taher
    Hamid Fazelirad
    Microchimica Acta, 2013, 180 : 1157 - 1163
  • [29] Comparative investigation on electrochemical behavior of hydroquinone at carbon ionic liquid electrode, ionic liquid modified carbon paste electrode and carbon paste electrode
    Zhang, Ya
    Zheng, Jian Bin
    ELECTROCHIMICA ACTA, 2007, 52 (25) : 7210 - 7216
  • [30] Electroactive ceramic carbon electrode modified with ionic liquid
    Rozniecka, E
    Shul, G
    Sirieix-Plenet, J
    Gaillon, L
    Opallo, M
    ELECTROCHEMISTRY COMMUNICATIONS, 2005, 7 (03) : 299 - 304