Direct shear behavior of concrete filled hollow steel tube shear connector for slim-floor steel beams

被引:133
|
作者
Hosseinpour, Emad [1 ]
Baharom, Shahrizan [1 ]
Badaruzzaman, Wan Hamidon W. [1 ]
Shariati, Mahdi [2 ]
Jalali, Abdolrahim [2 ]
机构
[1] Univ Kebangsaan Malaysia, Fac Engn & Built Environm, Dept Civil & Struct Engn, Bangi 43600, Selangor, Malaysia
[2] Univ Tabriz, Fac Civil Engn, Bahman Blvd, Tabriz 5166616471, Iran
来源
STEEL AND COMPOSITE STRUCTURES | 2018年 / 26卷 / 04期
关键词
slim-floor; hollow steel tube; shear connector; push-out test; energy absorption capacity; COMPOSITE BEAMS; DESIGN;
D O I
10.12989/scs.2018.26.4.485
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, a hollow steel tube (HST) shear connector is proposed for use in a slim-floor system. The HST welded to a perforated steel beam web and embedded in concrete slab. A total of 10 push-out tests were conducted under static loading to investigate the mechanical behavior of the proposed HST connector. The variables were the shapes (circular, square and rectangular) and sizes of hollow steel tubes, and the compressive strength of the concrete. The failure mode was recorded as: concrete slab compressive failure under the steel tube and concrete tensile splitting failure, where no failure occurred in the HST. Test results show that the square shape HST in filled via concrete strength 40 MPa carried the highest shear load value, showing three times more than the reference specimens. It also recorded less slip behavior, and less compressive failure mode in concrete underneath the square hollow connector in comparison with the circular and rectangular HST connectors in both concrete strengths. The rectangular HST shows a 20% higher shear resistance with a longer width in the load direction in comparison with that in the smaller dimension. The energy absorption capacity values showed 23% and 18% improvements with the square HST rather than a headed shear stud when embedded in concrete strengths of 25 MPa and 40 MPa, respectively. Moreover, an analytical method was proposed and predicts the shear resistance of the HST shear connectors with a standard deviation of 0.14 considering the shape and size of the connectors.
引用
收藏
页码:485 / 499
页数:15
相关论文
共 50 条
  • [41] Shear capacity of concrete-filled steel plate composite coupling beams
    Hu, Hong-Song
    Nie, Jian-Guo
    Wang, Yu-Hang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 118 : 76 - 90
  • [42] Experimental study on shear resistance performance of concrete filled steel tube shear block stub columns
    Huang, Yong
    Chen, Weigang
    Duan, Li
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2011, 32 (12): : 178 - 185
  • [43] Test on shear performance of concrete filled square CFRP-steel tube
    Chen D.
    Wang Q.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2018, 39 : 162 - 168
  • [44] Pure Shear Capacity Analysis on Square Tube Filled with Steel Reinforced Concrete
    Ou, Yangwei
    Zhao, Tongfeng
    Zhen, Xiaodong
    ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 : 1578 - +
  • [45] Flexural and shear behavior of bolt-connected U-shaped steel beams filled with concrete
    Kim, Chul-Goo
    Lee, Sang-Hyun
    STEEL AND COMPOSITE STRUCTURES, 2024, 53 (01): : 61 - 75
  • [46] Flexural behavior of composite beams with concrete filled steel tube flanges and honeycombed steel webs
    Ji, Jing
    Li, Yunhao
    Jiang, Liangqin
    Ren, Hongguo
    Wang, Qingqin
    Zhang, Lei
    He, Lingjie
    Zhang, Zhanbin
    FRONTIERS IN MATERIALS, 2022, 9
  • [47] Seismic behavior of prefabricated concrete filled steel tube-bordered monolayer reinforced shear wall
    Yin, Fei
    Cao, Wan-Lin
    Wang, Ru-Wei
    Weng, Hao-Feng
    Liu, Yi-Bin
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 194
  • [48] Seismic behavior of prefabricated concrete filled steel tube-bordered monolayer reinforced shear wall
    Yin, Fei
    Cao, Wan-Lin
    Wang, Ru-Wei
    Weng, Hao-Feng
    Liu, Yi-Bin
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 194
  • [49] Shear behavior of prefabricated steel-concrete connectors in prefabricated steel-concrete composite beams
    Zhou, Fengli
    Liang, Huaping
    Jiang, Jinlong
    Zhou, Zhixiang
    Zou, Yang
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [50] Simplified method for the determination of the influence of flexibility of shear connection on deflections of composite beams and slim-floor systems
    Hanswille, Gerhard
    Schaefer, Markus
    STAHLBAU, 2007, 76 (11) : 845 - 854