Direct shear behavior of concrete filled hollow steel tube shear connector for slim-floor steel beams

被引:133
|
作者
Hosseinpour, Emad [1 ]
Baharom, Shahrizan [1 ]
Badaruzzaman, Wan Hamidon W. [1 ]
Shariati, Mahdi [2 ]
Jalali, Abdolrahim [2 ]
机构
[1] Univ Kebangsaan Malaysia, Fac Engn & Built Environm, Dept Civil & Struct Engn, Bangi 43600, Selangor, Malaysia
[2] Univ Tabriz, Fac Civil Engn, Bahman Blvd, Tabriz 5166616471, Iran
来源
STEEL AND COMPOSITE STRUCTURES | 2018年 / 26卷 / 04期
关键词
slim-floor; hollow steel tube; shear connector; push-out test; energy absorption capacity; COMPOSITE BEAMS; DESIGN;
D O I
10.12989/scs.2018.26.4.485
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, a hollow steel tube (HST) shear connector is proposed for use in a slim-floor system. The HST welded to a perforated steel beam web and embedded in concrete slab. A total of 10 push-out tests were conducted under static loading to investigate the mechanical behavior of the proposed HST connector. The variables were the shapes (circular, square and rectangular) and sizes of hollow steel tubes, and the compressive strength of the concrete. The failure mode was recorded as: concrete slab compressive failure under the steel tube and concrete tensile splitting failure, where no failure occurred in the HST. Test results show that the square shape HST in filled via concrete strength 40 MPa carried the highest shear load value, showing three times more than the reference specimens. It also recorded less slip behavior, and less compressive failure mode in concrete underneath the square hollow connector in comparison with the circular and rectangular HST connectors in both concrete strengths. The rectangular HST shows a 20% higher shear resistance with a longer width in the load direction in comparison with that in the smaller dimension. The energy absorption capacity values showed 23% and 18% improvements with the square HST rather than a headed shear stud when embedded in concrete strengths of 25 MPa and 40 MPa, respectively. Moreover, an analytical method was proposed and predicts the shear resistance of the HST shear connectors with a standard deviation of 0.14 considering the shape and size of the connectors.
引用
收藏
页码:485 / 499
页数:15
相关论文
共 50 条
  • [31] Heat transfer analysis of concrete-filled steel tubular columns to slim-floor beam connections subjected to fire
    Romero, Manuel L.
    Albero, Vicente
    Espinös, Ana
    Hospitaler, Antonio
    Pascual, Ana M.
    ce/papers, 2017, 1 (5-6) : 311 - 316
  • [32] Shear response of steel fiber reinforced recycled concrete-filled steel tube columns
    Liu, Zhenzhen
    Lu, Yiyan
    Li, Shan
    Liao, Jiancong
    ADVANCES IN STRUCTURAL ENGINEERING, 2021, 24 (12) : 2684 - 2704
  • [33] Shear behavior and shear capacity prediction of precast concrete-encased steel beams
    Yu, Yunlong
    Yang, Yong
    Xue, Yicong
    Liu, Yaping
    STEEL AND COMPOSITE STRUCTURES, 2020, 36 (03): : 261 - 272
  • [34] Dynamic analysis and shear connector damage identification of steel-concrete composite beams
    Hou, Zhongming
    Xia, He
    Zhang, YanLing
    STEEL AND COMPOSITE STRUCTURES, 2012, 13 (04): : 327 - 341
  • [35] Experimental Study of the New Type Stud Shear Connector for Assembled Steel–Concrete Beams
    Senqiang Lu
    Wei Zhao
    Zhenzhu Guo
    Iranian Journal of Science and Technology, Transactions of Civil Engineering, 2022, 46 : 3119 - 3130
  • [36] An experimental and analytical study of a new shear connector for composite steel-concrete beams
    Matus, RA
    Jullien, JF
    ADVANCES IN STEEL STRUCTURES, VOLS 1 AND 2, 1996, : 413 - 418
  • [37] Mechanical behavior of stud shear connector in steel fiber reinforced concrete (SFRC)
    Xu, C.
    Masuya, H.
    Fukada, S.
    LIFE-CYCLE OF STRUCTURAL SYSTEMS: DESIGN, ASSESSMENT, MAINTENANCE AND MANAGEMENT, 2015, : 784 - 790
  • [38] Behavior of steel and concrete composite beams with a newly puzzle shape of crestbond rib shear connector: an experimental study
    Van Phuoc Nhan Le
    Duc Vinh Bui
    Thi Hai Vinh Chu
    Kim, In-Tae
    Ahn, Jin-Hee
    Dao, Duy Kien
    STRUCTURAL ENGINEERING AND MECHANICS, 2016, 60 (06) : 1001 - 1019
  • [39] Shear forces transfer in steel-concrete slim floor with circular web opening and PCHCS
    Coldebella, Gustavo
    Ferreira, Felipe Piana Vendramell
    De Nardin, Silvana
    STRUCTURES, 2022, 38 : 1295 - 1307
  • [40] Concrete-filled steel tubes as coupling beams for RC shear walls
    Teng, JG
    Chen, JF
    Lee, YC
    ADVANCES IN STEEL STRUCTURES, VOLS 1 AND 2, 1999, : 391 - 399