Applicability of new configuration of open tubular solid phase microextraction for determination of free (unconjugated) testosterone esters by gas chromatography with barrier ionization discharge detector

被引:5
|
作者
de Oliveira, Jhonatan Bispo [1 ]
Ferreira, Venilton Menezes Vieira [1 ]
Patricio, Patricia Santiago de Oliveira [1 ]
de Souza, Patterson Patricio [1 ]
机构
[1] Ctr Fed Educ Tecnol Minas Gerais, Chem Dept, CEFET MG, Ave Amazonas 5833, BR-30510000 Belo Horizonte, MG, Brazil
关键词
Testosterone esters; Barrier ionization discharge detector; Open tube trapping solid-phase micro; extraction; Validation; Gas chromatography; MASS-SPECTROMETRY; ANABOLIC-STEROIDS; CAPILLARY MICROEXTRACTION; THERMAL-DESORPTION; WATER SAMPLES; HUMAN HAIR; VALIDATION; AGENTS; DRUGS;
D O I
10.1016/j.microc.2022.108104
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The methodology has been developed for analyzing testosterone esters in urine by gas chromatography with a barrier ionization discharge (GC-BID) detector for anti-doping analysis. For sample preparation, poly-dimethylsiloxane (PDMS) was used as a trapping polymer in the new configuration of an open tube trapping solid-phase microextraction (OTT-SPME). The new device developed by this research group was called Intra Tube Flux Extraction (IT-FEX-SPME). The performance of the IT-FEX-SPME-GC-BID method was validated concerning extraction kinetics, sensitivity: the limit of detection (LOD 0.5-0.8 ng mL-1) and the limit of quantification (LOQ 1.5-2.4 ng mL-1), repeatability (<8%), reproducibility <7.5 %), linearity (R2>0.991), re-covery (mean 102.44 %), and stability (<30 %). The values obtained are acceptable, and the results showed the potentiality of the methodology to control testosterone ester doping. The qualitative performance of the pro-posed method is compared with those that use a mass spectrometer as a detector.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] SOLID-PHASE MICROEXTRACTION FOR THE DETERMINATION OF THE FREE CONCENTRATION OF VALPROIC ACID IN HUMAN PLASMA BY CAPILLARY GAS-CHROMATOGRAPHY
    KROGH, M
    JOHANSEN, K
    TONNESEN, F
    RASMUSSEN, KE
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1995, 673 (02): : 299 - 305
  • [32] A quantitative headspace-solid-phase microextraction-gas chromatography-flame ionization detector method to analyze short chain free fatty acids in rat feces
    Fiorini, Dennis
    Boarelli, Maria Chiara
    Gabbianelli, Rosita
    Ballini, Roberto
    Pacetti, Deborah
    ANALYTICAL BIOCHEMISTRY, 2016, 508 : 12 - 14
  • [33] Silica-Based Ionogels: Nanoconfined Ionic Liquid-Rich Fibers for Headspace Solid-Phase Microextraction Coupled with Gas Chromatography-Barrier Discharge Ionization Detection
    Pena-Pereira, Francisco
    Marcinkowski, Lukasz
    Kloskowski, Adam
    Namiesnik, Jacek
    ANALYTICAL CHEMISTRY, 2014, 86 (23) : 11640 - 11648
  • [34] Development of a headspace solid-phase microextraction method combined with gas chromatography mass spectrometry for the determination of phthalate esters in cow milk
    Feng, YL
    Zhu, JP
    Sensenstein, R
    ANALYTICA CHIMICA ACTA, 2005, 538 (1-2) : 41 - 48
  • [35] Determination of Gaseous Formic and Acetic Acids by a Needle-Type Extraction Device coupled to a Gas Chromatography-Barrier Discharge Ionization Detector
    Ikuo Ueta
    Yohei Nakamura
    Koji Fujimura
    Susumu Kawakubo
    Yoshihiro Saito
    Chromatographia, 2017, 80 : 151 - 156
  • [36] Determination of Gaseous Formic and Acetic Acids by a Needle-Type Extraction Device coupled to a Gas Chromatography-Barrier Discharge Ionization Detector
    Ueta, Ikuo
    Nakamura, Yohei
    Fujimura, Koji
    Kawakubo, Susumu
    Saito, Yoshihiro
    CHROMATOGRAPHIA, 2017, 80 (01) : 151 - 156
  • [37] A carbon dots-based coating for the determination of phthalate esters by solid-phase microextraction coupled gas chromatography in water samples
    Wu, Dechang
    Chen, Xiulin
    Liu, Fu
    Wu, Jian-Feng
    Zhao, Guang-Chao
    MICROCHEMICAL JOURNAL, 2020, 159
  • [38] New fast screening method for organochlorine pesticides in water by using solid-phase microextraction with fast gas chromatography and a pulsed-discharge electron capture detector
    Jackson, GP
    Andrews, ARJ
    ANALYST, 1998, 123 (05) : 1085 - 1090
  • [39] Matrix solid-phase dispersion microextraction and determination of pesticide residues in medicinal herbs by gas chromatography with a nitrogen-phosphorus detector
    Tang, Feng
    Yue, Yongde
    Hua, Rimao
    Cao, Haiqun
    Journal of AOAC International, 2006, 89 (02): : 498 - 502
  • [40] Determination of acrylamide in food by solid-phase microextraction coupled to gas chromatography-positive chemical ionization tandem mass spectrometry
    Lee, Maw-Rong
    Chang, Li-Yo
    Dou, Jianpeng
    ANALYTICA CHIMICA ACTA, 2007, 582 (01) : 19 - 23