Comparison of traditional and CRMC ejector performance used in a steam ejector refrigeration

被引:15
|
作者
Kitrattana, Borirak [1 ]
Aphornratana, Satha [1 ]
Thongtip, Tongchana [2 ]
Ruangtrakoon, Natthawut [3 ]
机构
[1] Thammasat Univ, Sirindhorn Int Inst Technol, Dept Mech Engn, Bangkok 12121, Thailand
[2] Phranakhon Rajabhat Univ, Fac Ind Technol, Dept Energy Engn, Bangkok 10220, Thailand
[3] King Mongkuts Inst Technol Ladkrabang, Dept Mech Engn, Fac Engn, Bangkok 10520, Thailand
关键词
Ejector; Refrigeration cycle; CRMC; Entrainment ratio;
D O I
10.1016/j.egypro.2017.10.229
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, performance of a steam ejector designed based on the constant rate of momentum change (CRMC) and traditional ejector were tested in an attempt to compare its performance. Three different ejectors were designed and constructed; traditional ejector with throat diameter of 19 mm, traditional ejector with throat diameter of 13.4 mm, and CRMC ejector with throat diameter of 13.4 mm. They were designed to be easily equipped with the 1kW experimental ejector refrigerator. The boiler saturation pressure was varied from 130 degrees C to 140 degrees. The evaporator saturation temperature were fixed at 7.5 degrees C. The result show that at the same operating condition and the same ejector area ratio (the area ratio of nozzle throat to ejector throat), CRMC ejector provided higher entrainment ratio than the traditional ejectors while the critical condenser pressure remain the same. (C) 2017 The Authors. Published by Elsevier Ltd. Peer-review under responsibility of the scientific committee of the 2017 International Conference on Alternative Energy in Developing Countries and Emerging Economies.
引用
收藏
页码:476 / 481
页数:6
相关论文
共 50 条
  • [41] Analysis of steam ejector performance with corrugated nozzle
    Qu, Xiaohang
    Tian, Maocheng
    Luo, Lincong
    Leng, Xueli
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2014, 34 (35): : 6255 - 6262
  • [42] A New Method for Desalination of Seawater With Steam-Ejector Refrigeration Plant
    Chen, Jinzeng
    Li, Yanfei
    Li, G. H.
    ADVANCES IN STRUCTURAL ENGINEERING, PTS 1-3, 2011, 94-96 : 273 - 279
  • [43] Ejector refrigeration: A comprehensive review
    Besagni, Giorgio
    Mereu, Riccardo
    Inzoli, Fabio
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 53 : 373 - 407
  • [44] Future perspectives in ejector refrigeration
    Milazzo, Adriano
    Mazzelli, Federico
    APPLIED THERMAL ENGINEERING, 2017, 121 : 344 - 350
  • [45] Experimental Investigation of Operating Characteristics of Ejector in Steam Jet Refrigeration System
    Wang, Xiao-Dong
    Fu, Qiang
    Yi, Shu
    Li, He
    Dongbei Daxue Xuebao/Journal of Northeastern University, 2017, 38 (12): : 1744 - 1747
  • [46] NUMERICAL MODELING OF A SUPERSONIC STEAM EJECTOR FOR A HEAT POWERED REFRIGERATION SYSTEMS
    Mazzelli, Federico
    Giacomelli, Francesco
    Milazzo, Adriano
    13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES, 2018, : 1315 - 1323
  • [47] The effect of operating conditions on the performance of a supersonic ejector for refrigeration
    Aidoun, Z
    Ouzzane, A
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (08): : 974 - 984
  • [48] Steam ejector fundamentals
    Chemical Processing, 1998, 61 (07):
  • [49] Performance analysis of a two-stage ejector in an ejector refrigeration system using computational fluid dynamics
    Suvarnakuta, N.
    Pianthong, K.
    Sriveerakul, T.
    Seehanam, W.
    ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2020, 14 (01) : 669 - 682
  • [50] Effect of generator temperature on steam ejector performance in renewable refrigeration cycle considering wet steam model and dry steam model
    Jiang, Jian
    Yin, Yanping
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY DEVELOPMENT-IJRED, 2024, 13 (03): : 386 - 395