Comparison of traditional and CRMC ejector performance used in a steam ejector refrigeration

被引:15
|
作者
Kitrattana, Borirak [1 ]
Aphornratana, Satha [1 ]
Thongtip, Tongchana [2 ]
Ruangtrakoon, Natthawut [3 ]
机构
[1] Thammasat Univ, Sirindhorn Int Inst Technol, Dept Mech Engn, Bangkok 12121, Thailand
[2] Phranakhon Rajabhat Univ, Fac Ind Technol, Dept Energy Engn, Bangkok 10220, Thailand
[3] King Mongkuts Inst Technol Ladkrabang, Dept Mech Engn, Fac Engn, Bangkok 10520, Thailand
关键词
Ejector; Refrigeration cycle; CRMC; Entrainment ratio;
D O I
10.1016/j.egypro.2017.10.229
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, performance of a steam ejector designed based on the constant rate of momentum change (CRMC) and traditional ejector were tested in an attempt to compare its performance. Three different ejectors were designed and constructed; traditional ejector with throat diameter of 19 mm, traditional ejector with throat diameter of 13.4 mm, and CRMC ejector with throat diameter of 13.4 mm. They were designed to be easily equipped with the 1kW experimental ejector refrigerator. The boiler saturation pressure was varied from 130 degrees C to 140 degrees. The evaporator saturation temperature were fixed at 7.5 degrees C. The result show that at the same operating condition and the same ejector area ratio (the area ratio of nozzle throat to ejector throat), CRMC ejector provided higher entrainment ratio than the traditional ejectors while the critical condenser pressure remain the same. (C) 2017 The Authors. Published by Elsevier Ltd. Peer-review under responsibility of the scientific committee of the 2017 International Conference on Alternative Energy in Developing Countries and Emerging Economies.
引用
收藏
页码:476 / 481
页数:6
相关论文
共 50 条
  • [21] CFD SIMULATION OF A SUPERSONIC STEAM EJECTOR FOR REFRIGERATION APPLICATION
    Su, Liju
    Agarwal, Ramesh K.
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, 2016, VOL 1A, 2016,
  • [22] Development and performance of steam ejector refrigeration system operated in real application in Thailand
    Ruangtrakoon, Natthawut
    Aphornratana, Satha
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 48 : 142 - 152
  • [23] Numerical investigation of roughness effect on wet steam ejector performance in the refrigeration cycle
    Rad, Mehdi Pouyan
    Lakzian, Esmail
    Gronman, Aki
    HEAT AND MASS TRANSFER, 2022, 58 (09) : 1545 - 1560
  • [24] Performance Characteristics of the Ejector Refrigeration System based on the Constant Pressure Ejector Flow Model
    Dong, Jingming
    Kang, Chunlu
    Wang, Hongming
    Chen, Xuli
    2015 4TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2015), 2015, : 3726 - 3732
  • [25] An investigation on the performance of solar ejector refrigeration system
    Zhang, B
    Shen, SQ
    ENERGY CONVERSION AND APPLICATION, VOL I AND II, 2001, : 1231 - 1234
  • [26] Experimental determination of the optimum performance of ejector refrigeration system depending on ejector area ratio
    Yapici, R.
    Ersoy, H. K.
    Aktoprakoglu, A.
    Halkaci, H. S.
    Yigit, O.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (07): : 1183 - 1189
  • [27] Performance characteristics of a methanol ejector refrigeration unit
    Alexis, GK
    Katsanis, JS
    ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (17) : 2729 - 2744
  • [28] A predictive model for the performance of the ejector in refrigeration system
    Liu, Jiapeng
    Wang, Lei
    Jia, Lei
    ENERGY CONVERSION AND MANAGEMENT, 2017, 150 : 269 - 276
  • [29] PERFORMANCE OF A STEAM-EJECTOR SCRUBBER
    SPARKS, LE
    MCCAIN, JD
    SMITH, WB
    JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1974, 24 (10): : 958 - 960
  • [30] Performance characteristics of the ejector refrigeration system based on the constant area ejector flow model
    Yapici, R
    Ersoy, HK
    ENERGY CONVERSION AND MANAGEMENT, 2005, 46 (18-19) : 3117 - 3135