摘要
The experimentation has been done using the winglet type vortex generator as a roughness element above the absorber surface of a solar air heater (SAH) system. Different geometry-based roughness parameters have been considered such as relative roughness pitch (P-i/e) value of 5-12, relative roughness width (W-w/w) value of 3-7, angle of attack (alpha) value of 30 degrees-75 degrees and the flowing fluid Reynolds number diversified between 3000 and 22,000 respectively and its effect on Nusselt number (Nu(u)) and friction factor (fr(1)) were studied. In order to achieve its optimum condition, the Nusselt number (Nu(u)) and friction factor (fr(1)) are analyzed for the roughness parameters to obtain the best overall performance and the required values are compared with the smooth type duct under similar flowing condition. Using regression analysis, correlations have been expanded for Nusselt number (Nu(u)) and friction component (fr(1)) in terms of Reynolds number (Re) and with different parametric condition which is considered to be satisfactory when compared with the experimental results.
引用
收藏
页码:334 / 348
页数:15
相关论文
共 50 条
  • [31] Performance of Solar Air Heater Having Absorber Plate Roughened with Protrusions of Different Shapes
    Soi, Aman
    Singh, Ranjit
    Bhushan, Brij
    PROCEEDINGS OF 2019 IEEE 2ND INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY AND POWER ENGINEERING (REPE 2019), 2019, : 177 - 181
  • [32] Thermo-hydraulic performance of solar air heater having winglet type roughness element
    Kumar, Amit
    Layek, Apurba
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2022, 147 (19) : 10481 - 10495
  • [33] Thermo-hydraulic performance of solar air heater having winglet type roughness element
    Amit Kumar
    Apurba Layek
    Journal of Thermal Analysis and Calorimetry, 2022, 147 : 10481 - 10495
  • [34] Effect of the number and placement of punched holes in rectangular winglet vortex generators on solar air heater performance
    Lertnuwat, Boonchai
    ENERGY CONVERSION AND MANAGEMENT-X, 2024, 24
  • [35] Heat transfer coefficient and friction factor correlations for rectangular solar air heater duct having transverse wedge shaped rib roughness on the absorber plate
    Bhagoria, JL
    Saini, JS
    Solanki, SC
    RENEWABLE ENERGY, 2002, 25 (03) : 341 - 369
  • [36] Heat transfer and friction characteristics of double pass solar air heater having V-shaped roughness on the absorber plate
    Sharma, Avdhesh
    Varun
    Kumar, Prashant
    Bharadwaj, Gaurav
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2013, 5 (02)
  • [37] Heat transfer and friction in rectangular solar air heater duct having spherical and inclined rib protrusions as roughness on absorber plate
    Prakash, Chandra
    Saini, R. P.
    EXPERIMENTAL HEAT TRANSFER, 2019, 32 (05) : 469 - 487
  • [38] Thermal performance analysis of corrugated plate solar air heater integrated with vortex generator
    Alnakeeb, Mohamed A.
    Hassan, Mohamed A.
    Teamah, Mohamed A.
    ALEXANDRIA ENGINEERING JOURNAL, 2024, 97 : 241 - 255
  • [39] Heat transmission and air flow friction in a solar air heater with a ribbed absorber plate: A computational study
    Alsaiari, Abdulmohsen O.
    Iqbal, Ahamed
    Abdulkhair, Hani
    Gzara, Lassaad
    Almatrafi, Eydhah
    Alzahrani, Hassan A. H.
    Madhukeshwara, N.
    Prasanna, B. M.
    Aljohani, Maha
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 40
  • [40] Performance Evaluation of Solar Air Heater Having Chamfered Rib Groove Roughness on Absorber Plate
    Layek, Apurba
    INTERNATIONAL CONFERENCE ON MODELING, OPTIMIZATION, AND COMPUTING, 2010, 1298 : 282 - 287