Solar air heater (SAH);
Winglet type vortex generator (WVG);
Regression analysis;
THERMOHYDRAULIC PERFORMANCE;
TRANSFER COEFFICIENT;
RIB;
AUGMENTATION;
ROUGHNESS;
DUCT;
D O I:
10.1016/j.solener.2020.05.047
中图分类号:
TE [石油、天然气工业];
TK [能源与动力工程];
学科分类号:
0807 ;
0820 ;
摘要:
The experimentation has been done using the winglet type vortex generator as a roughness element above the absorber surface of a solar air heater (SAH) system. Different geometry-based roughness parameters have been considered such as relative roughness pitch (P-i/e) value of 5-12, relative roughness width (W-w/w) value of 3-7, angle of attack (alpha) value of 30 degrees-75 degrees and the flowing fluid Reynolds number diversified between 3000 and 22,000 respectively and its effect on Nusselt number (Nu(u)) and friction factor (fr(1)) were studied. In order to achieve its optimum condition, the Nusselt number (Nu(u)) and friction factor (fr(1)) are analyzed for the roughness parameters to obtain the best overall performance and the required values are compared with the smooth type duct under similar flowing condition. Using regression analysis, correlations have been expanded for Nusselt number (Nu(u)) and friction component (fr(1)) in terms of Reynolds number (Re) and with different parametric condition which is considered to be satisfactory when compared with the experimental results.
机构:
Maulana Azad Natl Inst Technol MANIT, Dept Mech Engn, Link Road 3,Near Kali Mata Mandir, Bhopal 462003, Madhya Pradesh, IndiaMaulana Azad Natl Inst Technol MANIT, Dept Mech Engn, Link Road 3,Near Kali Mata Mandir, Bhopal 462003, Madhya Pradesh, India