A design for a compact time-of-flight mass spectrometer

被引:6
|
作者
Manard, Manuel J. [1 ]
机构
[1] Natl Secur Technol LLC, Special Technol Lab, Santa Barbara, CA 93111 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2012年 / 83卷 / 10期
关键词
SPACE-CHARGE; ION FUNNEL; OPTIMIZATION; PRESSURE; POWER; AIR;
D O I
10.1063/1.4757864
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The design of a prototype, compact time-of-flight (TOF) mass spectrometer is described. The system primarily consists of an ion acceleration/focusing/steering assembly (AFSA), an 8 cm field-free region, a 4 cm dual-stage reflectron, and a miniature microchannel plate detector. Consequently, the resulting flight length of the system is 12 cm. The system has been designed with the capability to sample directly from atmosphere at ambient pressures. This is accomplished through the use of an electrodynamic ion funnel, housed in an intermediate-vacuum chamber that is coupled to the inlet of the TOF chamber. TOF spectra were obtained using noble gases (Ar, Kr, and Xe) as test chemicals. These measured flight times were used to probe the performance of the instrument. A temporal resolution (t(flight)/Delta t) of approximately 125, acquired using Xe-129(+), has been measured for the system. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4757864]
引用
收藏
页数:7
相关论文
共 50 条
  • [31] A TANDEM TIME-OF-FLIGHT MASS-SPECTROMETER
    JARDINE, DR
    MORGAN, J
    ALDERDICE, DS
    DERRICK, PJ
    ORGANIC MASS SPECTROMETRY, 1992, 27 (10): : 1077 - 1083
  • [32] Time-of-flight mass spectrometer with improved resolution
    Karas, M
    JOURNAL OF MASS SPECTROMETRY, 1997, 32 (01): : 1 - 3
  • [33] A TIME-OF-FLIGHT MASS SPECTROMETER WITH VARYING FIELD
    HIPPLE, JA
    THOMAS, HA
    PHYSICAL REVIEW, 1949, 75 (10): : 1616 - 1616
  • [34] TANDEM TIME-OF-FLIGHT MASS-SPECTROMETER
    CORNISH, TJ
    COTTER, RJ
    ANALYTICAL CHEMISTRY, 1993, 65 (08) : 1043 - 1047
  • [35] A cylindrical reflectron time-of-flight mass spectrometer
    Vialle, JL
    Baguenard, B
    Bourgey, A
    Cottancin, E
    Lerme, J
    Palpant, B
    Pellarin, M
    Valadier, F
    Broyer, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (06): : 2312 - 2318
  • [36] A time-of-flight mass spectrometer to resolve isobars
    Ishida, Y
    Wada, M
    Matsuo, Y
    Tanihata, I
    Casares, A
    Wollnik, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 219 : 468 - 472
  • [37] A NEW TIME-OF-FLIGHT MASS-SPECTROMETER
    SU, CS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 220 (2-3): : 431 - 432
  • [38] NEW CAPABILITY FOR TIME-OF-FLIGHT MASS SPECTROMETER
    不详
    ANALYTICAL CHEMISTRY, 1965, 37 (8P1) : A95 - &
  • [39] An optimised compact electron impact ion storage source for a time-of-flight mass spectrometer
    Abplanalp, Dominic
    Wurz, Peter
    Huber, Liliane
    Leya, Ingo
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2010, 294 (01) : 33 - 39
  • [40] COMPACT TIME-OF-FLIGHT MASS-SPECTROMETER USING PARTICLE-INDUCED DESORPTION
    SUMMERS, WR
    SCHWEIKERT, EA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1986, 57 (04): : 692 - 694