A design for a compact time-of-flight mass spectrometer

被引:6
|
作者
Manard, Manuel J. [1 ]
机构
[1] Natl Secur Technol LLC, Special Technol Lab, Santa Barbara, CA 93111 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2012年 / 83卷 / 10期
关键词
SPACE-CHARGE; ION FUNNEL; OPTIMIZATION; PRESSURE; POWER; AIR;
D O I
10.1063/1.4757864
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The design of a prototype, compact time-of-flight (TOF) mass spectrometer is described. The system primarily consists of an ion acceleration/focusing/steering assembly (AFSA), an 8 cm field-free region, a 4 cm dual-stage reflectron, and a miniature microchannel plate detector. Consequently, the resulting flight length of the system is 12 cm. The system has been designed with the capability to sample directly from atmosphere at ambient pressures. This is accomplished through the use of an electrodynamic ion funnel, housed in an intermediate-vacuum chamber that is coupled to the inlet of the TOF chamber. TOF spectra were obtained using noble gases (Ar, Kr, and Xe) as test chemicals. These measured flight times were used to probe the performance of the instrument. A temporal resolution (t(flight)/Delta t) of approximately 125, acquired using Xe-129(+), has been measured for the system. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4757864]
引用
收藏
页数:7
相关论文
共 50 条
  • [21] MASS MEASUREMENTS WITH A MAGNETIC TIME-OF-FLIGHT MASS SPECTROMETER
    HAYS, EE
    RICHARDS, PI
    GOUDSMIT, SA
    PHYSICAL REVIEW, 1951, 84 (04): : 824 - 829
  • [22] AUTOMATIC MASS SCANNER FOR TIME-OF-FLIGHT MASS SPECTROMETER
    MCDOWELL, MV
    SAALFELD, FE
    OLFKY, RS
    ANALYTICAL CHEMISTRY, 1964, 36 (04) : 959 - &
  • [23] Selection and design of the secondary electron channel of the time-of-flight mass spectrometer
    T. Ya. Fishkova
    A. A. Basalaev
    V. V. Kuz’michev
    Technical Physics, 2016, 61 : 470 - 472
  • [24] Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer
    Tabrizchi, M.
    Farrokhpour, H.
    Abyar, F.
    Azad, H.
    Mirian, M.
    ILbeigi, V.
    PHYSICAL CHEMISTRY RESEARCH, 2014, 2 (02): : 202 - 216
  • [25] Optimisation of the design parameters of a reflectron geometry time-of-flight mass spectrometer
    Sankari, M
    Suryanarayana, MV
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 1996, 24 (01) : 23 - 36
  • [26] Selection and design of the secondary electron channel of the time-of-flight mass spectrometer
    Fishkova, T. Ya.
    Basalaev, A. A.
    Kuz'michev, V. V.
    TECHNICAL PHYSICS, 2016, 61 (03) : 470 - 472
  • [27] A TIME-OF-FLIGHT SPECTROMETER FOR MASS MEASUREMENTS AT LAMPF
    VIEIRA, DJ
    BUTLER, GW
    CLARK, JL
    WOUTERS, JM
    POSKANZER, AM
    REMSBERG, LP
    WOLLNIK, H
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1982, 183 (MAR): : 18 - NUCL
  • [28] A SEGMENTED TIME-OF-FLIGHT MASS-SPECTROMETER
    SRIVASTAVA, SK
    IGA, I
    RAO, MVVS
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1995, 6 (09) : 1379 - 1382
  • [29] A NEW TIME-OF-FLIGHT MASS-SPECTROMETER
    SAKURAI, T
    FUJITA, Y
    MATSUO, T
    MATSUDA, H
    KATAKUSE, I
    MISEKI, K
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1985, 66 (03): : 283 - 290
  • [30] TIME-OF-FLIGHT MASS SPECTROMETER WITH IMPROVED RESOLUTION
    WILEY, WC
    MCLAREN, IH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1955, 26 (12): : 1150 - 1157