Effect of errors in baseline optical properties on accuracy of transabdominal near-infrared spectroscopy in fetal sheep brain during hypoxic stress

被引:1
|
作者
Mawn, T
Nioka, S
Nijland, M
Bloy, L
Elliott, MA
Chance, B
Leigh, JS
机构
[1] Univ Penn, Dept Bioengn, Stellar Chance Labs B1, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Biochem & Biophys, Philadelphia, PA 19104 USA
[3] Cornell Univ, Dept Biomed Sci, Ithaca, NY 14853 USA
[4] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
关键词
diffusion theory; photon migration; hemoglobin; saturation;
D O I
10.1117/1.2118730
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A continuous-wave (cw) near-infrared spectroscopy (NIRS) instrument has been developed to noninvasively quantify fetal cerebral blood oxygen saturation (StO(2)). A linear Green's function formulism was used to analytically solve the photon diffusion equation and extract the time-varying fetal tissue oxy- and deoxy-hemoglobin concentrations from the NIR measurements. Here we explored the accuracy with which this instrument can be expected to perform over a range of fetal hypoxic states. We investigated the dependence of this accuracy on the accuracy of the reference optical properties chosen based on the literature. The fetal oxygenation of a pregnant ewe model was altered via maternal aortic occlusion. The NIR cw instrument was placed on the maternal abdomen directly above the fetal head, continuously acquiring diffuse optical measurements. Blood was sampled periodically from the fetus to obtain fetal arterial saturation (SaO(2)) measurements from blood gas analysis. The NIR StO(2) values were compared with the fetal SaO(2) measurements. Variations in the NIR results due to uncertainty in the reference optical properties were relatively small within the fetal SaO(2) range of 30 to 80%. Under hypoxic conditions, however, the variability of the NIR StO(2) calculations with changes in the assumed reference properties became more significant. (C) 2005 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Accurate optical parameter extraction procedure for broadband near-infrared spectroscopy of brain matter
    Sultan, Ebraheem
    Najafizadeh, Laleh
    Gandjbakhche, Amir H.
    Pourrezaei, Kambiz
    Daryoush, Afshin
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (01)
  • [42] Improving optical contact for functional near-infrared brain spectroscopy and imaging with brush optodes
    Khan, Bilal
    Wildey, Chester
    Francis, Robert
    Tian, Fenghua
    Delgado, Mauricio R.
    Liu, Hanli
    MacFarlane, Duncan
    Alexandrakis, George
    BIOMEDICAL OPTICS EXPRESS, 2012, 3 (05): : 878 - 898
  • [43] Functional optical brain imaging using near-infrared during cognitive tasks
    Izzetoglu, K
    Bunce, S
    Onaral, B
    Pourrezaei, K
    Chance, B
    INTERNATIONAL JOURNAL OF HUMAN-COMPUTER INTERACTION, 2004, 17 (02) : 211 - 227
  • [44] SIMULTANEOUS NEAR-INFRARED OPTICAL MONITORING OF INTACT BRAIN AND SKELETAL-MUSCLE TISSUES IN HYPOXIC STATES
    PIANTADOSI, CA
    HEMSTREET, TH
    JOBSISVANDERVLIET, FF
    CLINICAL RESEARCH, 1985, 33 (02): : A295 - A295
  • [45] BRAIN OXYGENATION ASSESSED BY NEAR-INFRARED SPECTROSCOPY DURING A MENTAL TASK AND A MILD PHYSICAL STRESS IN HEMODIALYSIS AND PERITONEAL DIALYSIS
    Faitatzidou, Danai
    Dipla, Konstantina
    Zafeiridis, Andreas
    Theodorakopoulou, Marieta
    Koutlas, Aggelos
    Polychronidou, Georgia
    Chalkidis, Georgios
    Dimitriadis, Chrysostomos
    Tsouchnikas, Ioannis
    Giamalis, Panagiotis
    Papagianni, Aikaterini
    Sarafidis, Pantelis
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2022, 37 : I502 - I502
  • [46] BRAIN OXYGENATION ASSESSED BY NEAR-INFRARED SPECTROSCOPY DURING A MENTAL TASK AND A MILD PHYSICAL STRESS IN HEMODIALYSIS AND PERITONEAL DIALYSIS
    Faitatzidou, Danai
    Dipla, Konstantina
    Zafeiridis, Andreas
    Theodorakopoulou, Marieta
    Koutlas, Aggelos
    Polychronidou, Georgia
    Chalkidis, Georgios
    Dimitriadis, Chrysostomos
    Tsouchnikas, Ioannis
    Giamalis, Panagiotis
    Papagianni, Aikaterini
    Sarafidis, Pantelis
    JOURNAL OF HYPERTENSION, 2022, 40 (SUPPL) : E247 - E247
  • [47] NEAR-INFRARED SPECTROSCOPY - A NEW TOOL FOR THE ASSESSMENT OF CEREBRAL HEMODYNAMICS DURING BRAIN ACTIVATION
    OBRIG, H
    DIRNAGL, U
    HOCK, C
    VILLRINGER, A
    STROKE, 1994, 25 (03) : 757 - 757
  • [48] Functional brain imaging using near-infrared spectroscopy during actual driving on an expressway
    Yoshino, Kayoko
    Oka, Noriyuki
    Yamamoto, Kouji
    Takahashi, Hideki
    Kato, Toshinori
    FRONTIERS IN HUMAN NEUROSCIENCE, 2013, 7
  • [49] Assessing the brain using near-infrared spectroscopy during postoperative ventricular circulatory support
    Giacomuzzi, Carmen
    Heller, Eileen
    Mejak, Brian
    You, Jamie
    Ungerleider, Ross
    Silberbach, Michael
    CARDIOLOGY IN THE YOUNG, 2005, 15 : 154 - 158
  • [50] Brain cell function during hypoxemia in near-term lambs: A near-infrared spectroscopy study
    Van Os, S
    Klaessens, J
    Hopman, J
    Liem, D
    Van de Bor, M
    BIOLOGY OF THE NEONATE, 2005, 88 (02): : 79 - 86