Effect of errors in baseline optical properties on accuracy of transabdominal near-infrared spectroscopy in fetal sheep brain during hypoxic stress

被引:1
|
作者
Mawn, T
Nioka, S
Nijland, M
Bloy, L
Elliott, MA
Chance, B
Leigh, JS
机构
[1] Univ Penn, Dept Bioengn, Stellar Chance Labs B1, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Biochem & Biophys, Philadelphia, PA 19104 USA
[3] Cornell Univ, Dept Biomed Sci, Ithaca, NY 14853 USA
[4] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
关键词
diffusion theory; photon migration; hemoglobin; saturation;
D O I
10.1117/1.2118730
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A continuous-wave (cw) near-infrared spectroscopy (NIRS) instrument has been developed to noninvasively quantify fetal cerebral blood oxygen saturation (StO(2)). A linear Green's function formulism was used to analytically solve the photon diffusion equation and extract the time-varying fetal tissue oxy- and deoxy-hemoglobin concentrations from the NIR measurements. Here we explored the accuracy with which this instrument can be expected to perform over a range of fetal hypoxic states. We investigated the dependence of this accuracy on the accuracy of the reference optical properties chosen based on the literature. The fetal oxygenation of a pregnant ewe model was altered via maternal aortic occlusion. The NIR cw instrument was placed on the maternal abdomen directly above the fetal head, continuously acquiring diffuse optical measurements. Blood was sampled periodically from the fetus to obtain fetal arterial saturation (SaO(2)) measurements from blood gas analysis. The NIR StO(2) values were compared with the fetal SaO(2) measurements. Variations in the NIR results due to uncertainty in the reference optical properties were relatively small within the fetal SaO(2) range of 30 to 80%. Under hypoxic conditions, however, the variability of the NIR StO(2) calculations with changes in the assumed reference properties became more significant. (C) 2005 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Near-Infrared Spectroscopy in the Analysis of Functional Brain Activity during Cognitive Tasks
    Abibullaev, Berdakh
    Lee, Seung Hyun
    Kang, Won-Seok
    An, Jinung
    Seo, Hee Don
    2010 IEEE SENSORS, 2010, : 542 - 547
  • [32] Brain Imaging During Exercise- Comparison of Electroencephalography and Near-Infrared Spectroscopy
    Abeln, Vera
    Askew, Christopher D.
    Vogt, Tobias
    Schneider, Stefan
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 770 - 771
  • [33] Brain activity during the flow experience: A functional near-infrared spectroscopy study
    Yoshida, Kazuki
    Sawamura, Daisuke
    Inagaki, Yuji
    Ogawa, Keita
    Ikoma, Katsunori
    Sakai, Shinya
    NEUROSCIENCE LETTERS, 2014, 573 : 30 - 34
  • [34] BRAIN ACTIVATION DURING JOINT ACTION MEASURED WITH FUNCTIONAL NEAR-INFRARED SPECTROSCOPY
    Egetemeir, Johanna
    Stenneken, Prisca
    Koehler, Saskia
    Fallgatter, Andreas J.
    Herrmann, Martin J.
    PSYCHOPHYSIOLOGY, 2009, 46 : S33 - S33
  • [35] Evaluation of brain oxygenation during selective cerebral perfusion by near-infrared spectroscopy
    Katoh, T
    Esato, K
    Gohra, H
    Hamano, K
    Fujimura, Y
    Zempo, N
    Nakashima, K
    Maekawa, T
    ANNALS OF THORACIC SURGERY, 1997, 64 (02): : 432 - 436
  • [36] Measurement of brain activity during lathe operation using near-infrared spectroscopy
    Hou, L. (leihou@mail.saitama-u.ac.jp), 1600, Japan Society of Mechanical Engineers (79):
  • [37] Brain activation during processing of emotional valence as measured with near-infrared spectroscopy
    Takahama, Sachiko
    Ohzawa, Izumi
    Yoshioka, Yoshichika
    NEUROSCIENCE RESEARCH, 2009, 65 : S238 - S238
  • [38] In vivo measure of neonate brain optical properties and hemodynamic parameters by time-domain near-infrared spectroscopy
    Spinelli, Lorenzo
    Zucchelli, Lucia
    Contini, Davide
    Caffini, Matteo
    Mehler, Jacques
    Flo, Ana
    Ferry, Alissa L.
    Filippin, Luca
    Macagno, Francesco
    Cattarossi, Luigi
    Torricelli, Alessandro
    NEUROPHOTONICS, 2017, 4 (04)
  • [39] Optical topography with near-infrared spectroscopy during a verbal-fluency task
    Herrmann, MJ
    Ehlis, AC
    Scheuerpflug, P
    Fallgatter, AJ
    JOURNAL OF PSYCHOPHYSIOLOGY, 2005, 19 (02) : 100 - 105
  • [40] MAGNETIC-RESONANCE AND NEAR-INFRARED SPECTROSCOPY FOR INVESTIGATION OF PERINATAL HYPOXIC-ISCHEMIC BRAIN INJURY
    WYATT, JS
    EDWARDS, AD
    AZZOPARDI, D
    REYNOLDS, EOR
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1989, 64 (07): : 953 - 963