Minimally invasive percutaneous plating of proximal humeral shaft fractures with the Proximal Humerus Internal Locking System (PHILOS)

被引:60
|
作者
Brunner, Alexander [1 ]
Thormann, Sebastian [1 ]
Babst, Reto [1 ]
机构
[1] Cantonal Hosp Lucerne, Dept Trauma Surg, CH-6000 Luzern 16, Switzerland
关键词
MIPO; minimally invasive; percutaneous; humeral fractures; PHILOS; DYNAMIC COMPRESSION PLATE; ANGULAR-STABLE PLATE; DIAPHYSEAL FRACTURES; INTRAMEDULLARY NAIL; OSTEOSYNTHESIS MIPO; FIXATION; SHOULDER; EXPERIENCE; TRAUMA; MIDDLE;
D O I
10.1016/j.jse.2011.05.016
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: This study evaluated our results after minimally invasive percutaneous plating of proximal humeral shaft fractures with the Proximal Humerus Internal Locking System (PHILOS, Synthes, Switzerland). Materials and methods: Between 2005 and 2008, 15 patients with unilateral displaced proximal humeral shaft fractures were treated and followed up over a median period of 27 months (range, 12-38 months). The final follow-up included anteroposterior and lateral x-rays, range of shoulder motion, pain by visual analog scale (VAS), the Constant-Murley shoulder score, the Disabilities of Arm, Shoulder and Elbow (DASH) score, and the Short Form 36 (SF36) assessment. Results: No intraoperative or postoperative complications occurred. No secondary fracture displacement or radial neuropathy was observed postoperatively. One patient had open reduction and internal fixation for pseudoarthrosis 16 months after the initial surgery. At the final follow-up, the median range of motion of the operated shoulder was flexion, 145 degrees; extension, 45 degrees; internal rotation, 40 degrees; external rotation, 70 degrees; and abduction, 135 degrees. Median results on outcome assessments were VAS pain score, 0 points; Constant-Murley score, 74 points, representing 87.5% of the median Constant-Murley score of the unaffected shoulder; DASH score, 34 points, and the SF36, 83 points. Conclusion: Minimally invasive percutaneous plating with the PHILOS offers a valid option in the treatment of proximal humeral shaft fractures with comparable rates of nonunion and lower rates of radial neuropathy compared with open procedures. Furthermore, the results indicate that this method is associated with lower rates of wound infection and a shorter stay in the hospital for the patient. Level of evidence: Level IV, Case Series, Treatment Study. (C) 2012 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:1056 / 1063
页数:8
相关论文
共 50 条
  • [31] Avoiding Complications of Locking Plating for Proximal Humerus Fractures
    Kokkalis Z.T.
    Papanikos E.
    Bavelou E.
    Panagopoulos A.
    Megas P.
    Journal of Long-Term Effects of Medical Implants, 2022, 32 (03) : 73 - 81
  • [32] Minimal Invasive Percutaneous Osteosynthesis for Elderly Valgus Impacted Proximal Humeral Fractures with the PHILOS
    Chen, Hang
    Hu, Xiaochuan
    Tang, Haochen
    Yang, Guoyong
    Xiang, Ming
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [33] Minimal invasive PHILOS®-plate osteosynthesis of proximal humerus fractures
    Acklin, Y. P.
    Jenni, R.
    Walliser, M.
    Sommer, C.
    BRITISH JOURNAL OF SURGERY, 2007, 94 (06) : 769 - 769
  • [34] Minimal Invasive PHILOS®-Plate Osteosynthesis in Proximal Humeral Fractures
    Acklin, Yves P.
    Jenni, Raphael
    Walliser, Martin
    Sommer, Christoph
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2009, 35 (01) : 35 - 39
  • [35] Long term results of minimal invasive deltoid split versus standard del-toidopectoral approach for PHILOS (proximal humeral internal locking system) osteosynthesis in proximal humeral fractures
    Borer, J.
    Babians, A.
    Schwarz, J.
    Potthast, S.
    Jakob, M.
    Lenzlinger, P.
    Zingg, U.
    BRITISH JOURNAL OF SURGERY, 2017, 104 : 16 - 16
  • [36] Early results of treatment of proximal humerus fractures with the PHILOS locking plate
    Kilic, Buelent
    Uysal, Mustafa
    Cinar, Bekir Murat
    Oezkoc, Guerkan
    Demiroers, Hueseyin
    Akpinar, Sercan
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2008, 42 (03) : 149 - 153
  • [37] Minimally invasive plating for complex humeral shaft fractures
    Rui Jiang
    Cong-Feng Luo
    Bing-Fang Zeng
    Guo-Hua Mei
    Archives of Orthopaedic and Trauma Surgery, 2007, 127 : 531 - 535
  • [38] Minimally invasive plating for complex humeral shaft fractures
    Jiang, Rui
    Luo, Cong-Feng
    Zeng, Bing-Fang
    Mei, Guo-Hua
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2007, 127 (07) : 531 - 535
  • [39] Percutaneous humeral plating of fractures of the proximal humerus: Results of a prospective Multicenter clinical trial
    Laflamme, George Yves
    Rouleau, Dominique M.
    Berry, Gregory K.
    Beaumont, Pierre H.
    Reindl, Rudo F.
    Harvey, Edward J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (03) : 153 - 158
  • [40] Proximal Humeral Fracture Treated with Proximal Humeral Internal Locking System (PHILOS) via a T-Shaped Small Incision
    Yuan, Feng
    Han, Yingchao
    Pan, Zhangyi
    Ma, Min
    Lu, Liangyu
    Wang, Han
    Zeng, Wen
    Luo, Shulin
    Cai, Junfeng
    Zhou, Wei
    Yin, Feng
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (02) : 374 - 377