Minimally invasive percutaneous plating of proximal humeral shaft fractures with the Proximal Humerus Internal Locking System (PHILOS)

被引:60
|
作者
Brunner, Alexander [1 ]
Thormann, Sebastian [1 ]
Babst, Reto [1 ]
机构
[1] Cantonal Hosp Lucerne, Dept Trauma Surg, CH-6000 Luzern 16, Switzerland
关键词
MIPO; minimally invasive; percutaneous; humeral fractures; PHILOS; DYNAMIC COMPRESSION PLATE; ANGULAR-STABLE PLATE; DIAPHYSEAL FRACTURES; INTRAMEDULLARY NAIL; OSTEOSYNTHESIS MIPO; FIXATION; SHOULDER; EXPERIENCE; TRAUMA; MIDDLE;
D O I
10.1016/j.jse.2011.05.016
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: This study evaluated our results after minimally invasive percutaneous plating of proximal humeral shaft fractures with the Proximal Humerus Internal Locking System (PHILOS, Synthes, Switzerland). Materials and methods: Between 2005 and 2008, 15 patients with unilateral displaced proximal humeral shaft fractures were treated and followed up over a median period of 27 months (range, 12-38 months). The final follow-up included anteroposterior and lateral x-rays, range of shoulder motion, pain by visual analog scale (VAS), the Constant-Murley shoulder score, the Disabilities of Arm, Shoulder and Elbow (DASH) score, and the Short Form 36 (SF36) assessment. Results: No intraoperative or postoperative complications occurred. No secondary fracture displacement or radial neuropathy was observed postoperatively. One patient had open reduction and internal fixation for pseudoarthrosis 16 months after the initial surgery. At the final follow-up, the median range of motion of the operated shoulder was flexion, 145 degrees; extension, 45 degrees; internal rotation, 40 degrees; external rotation, 70 degrees; and abduction, 135 degrees. Median results on outcome assessments were VAS pain score, 0 points; Constant-Murley score, 74 points, representing 87.5% of the median Constant-Murley score of the unaffected shoulder; DASH score, 34 points, and the SF36, 83 points. Conclusion: Minimally invasive percutaneous plating with the PHILOS offers a valid option in the treatment of proximal humeral shaft fractures with comparable rates of nonunion and lower rates of radial neuropathy compared with open procedures. Furthermore, the results indicate that this method is associated with lower rates of wound infection and a shorter stay in the hospital for the patient. Level of evidence: Level IV, Case Series, Treatment Study. (C) 2012 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:1056 / 1063
页数:8
相关论文
共 50 条
  • [21] Mid-term results of minimally invasive deltoid-split versus standard open deltopectoral approach for PHILOS™ (proximal humeral internal locking system) osteosynthesis in proximal humeral fractures
    Borer, Joelle
    Schwarz, Jochen
    Potthast, Silke
    Jakob, Marcel
    Lenzlinger, Philipp
    Zingg, Urs
    Babians, Arby
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2020, 46 (04) : 825 - 834
  • [22] Study of Functional Outcome and Postoperative Complications Among Proximal Humerus Fracture Patients Treated With Proximal Humerus Internal Locking System (PHILOS) Plating
    Jhamnani, Rohit
    Dhanda, Manjeet Singh
    Surana, Avinash
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (07)
  • [23] Minimally invasive percutaneous plate osteosynthesis for the treatment of proximal humerus fractures in osteoporotic patients with Philos plate
    Sahu, R. J. L.
    BANGLADESH JOURNAL OF MEDICAL SCIENCE, 2013, 12 (02): : 140 - 145
  • [24] Assessment of Screw Length of Proximal Humerus Internal Locking System (PHILOS) Plate for Proximal Humeral Fractures Using Three-Dimensional Computed Tomography Scan
    Qiang, Minfei
    Jia, Xiaoyang
    Chen, Yanxi
    Zhang, Kun
    Li, Haobo
    Jiang, Yuchen
    Zhang, Yijie
    MEDICAL SCIENCE MONITOR, 2018, 24 : 1158 - 1165
  • [25] Open Reduction and Internal Fixation of Proximal Humeral Fractures with Use of the Locking Proximal Humerus Plate
    Court-Brown, Charles M.
    McQueen, Margaret
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (11): : 2771 - 2771
  • [26] Open Reduction and Internal Fixation of Proximal Humeral Fractures with Use of the Locking Proximal Humerus Plate
    Konrad, G.
    Bayer, J.
    Hepp, P.
    Voigt, C.
    Oestern, H.
    Kaeaeb, N.
    Luo, C.
    Plecko, M.
    Wendt, K.
    Koestler, W.
    Suedkamp, N.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A : 85 - 95
  • [27] Clinical Results for Minimally Invasive Locked Plating of Proximal Humerus Fractures
    Roederer, Goetz
    Erhardt, Johannes
    Graf, Michael
    Kinzl, Lothar
    Gebhard, Florian
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (07) : 400 - 406
  • [28] Comparison of the Effects of Proximal Humeral Internal Locking System (PHILOS) Alone and PHILOS Combined with Fibular Allograft in the Treatment of Neer Three- or Four-part Proximal Humerus Fractures in the Elderly
    Zhao, Lei
    Qi, Yi-min
    Yang, Lei
    Wang, Gang-rui
    Zheng, Sheng-nai
    Wang, Qiang
    Liang, Bin
    Jiang, Chun-zhi
    ORTHOPAEDIC SURGERY, 2019, 11 (06) : 1003 - 1012
  • [29] Minimally Invasive Technique with Long Proximal Humeral Locking Plate for Treatment of Osteoporotic Humeral Shaft Fractures in Elderly Patients
    Yang, L. H.
    Wang, R.
    Liu, W.
    An, L. K.
    Kong, X. C.
    Li, J.
    Hong, G.
    Zhu, W. Y.
    Guo, Z. C.
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2013, 61 : S337 - S337
  • [30] Results of open reduction and internal fixation of proximal humerus fractures using a proximal humeral plating system with smooth pegs
    Kjaer, Christoffer
    Hillblom, Magnus
    Lenholm, Emma
    Windhamre, Helena Bostrom
    Ekelund, Anders
    SHOULDER & ELBOW, 2025,