Minimally invasive percutaneous plating of proximal humeral shaft fractures with the Proximal Humerus Internal Locking System (PHILOS)

被引:60
|
作者
Brunner, Alexander [1 ]
Thormann, Sebastian [1 ]
Babst, Reto [1 ]
机构
[1] Cantonal Hosp Lucerne, Dept Trauma Surg, CH-6000 Luzern 16, Switzerland
关键词
MIPO; minimally invasive; percutaneous; humeral fractures; PHILOS; DYNAMIC COMPRESSION PLATE; ANGULAR-STABLE PLATE; DIAPHYSEAL FRACTURES; INTRAMEDULLARY NAIL; OSTEOSYNTHESIS MIPO; FIXATION; SHOULDER; EXPERIENCE; TRAUMA; MIDDLE;
D O I
10.1016/j.jse.2011.05.016
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: This study evaluated our results after minimally invasive percutaneous plating of proximal humeral shaft fractures with the Proximal Humerus Internal Locking System (PHILOS, Synthes, Switzerland). Materials and methods: Between 2005 and 2008, 15 patients with unilateral displaced proximal humeral shaft fractures were treated and followed up over a median period of 27 months (range, 12-38 months). The final follow-up included anteroposterior and lateral x-rays, range of shoulder motion, pain by visual analog scale (VAS), the Constant-Murley shoulder score, the Disabilities of Arm, Shoulder and Elbow (DASH) score, and the Short Form 36 (SF36) assessment. Results: No intraoperative or postoperative complications occurred. No secondary fracture displacement or radial neuropathy was observed postoperatively. One patient had open reduction and internal fixation for pseudoarthrosis 16 months after the initial surgery. At the final follow-up, the median range of motion of the operated shoulder was flexion, 145 degrees; extension, 45 degrees; internal rotation, 40 degrees; external rotation, 70 degrees; and abduction, 135 degrees. Median results on outcome assessments were VAS pain score, 0 points; Constant-Murley score, 74 points, representing 87.5% of the median Constant-Murley score of the unaffected shoulder; DASH score, 34 points, and the SF36, 83 points. Conclusion: Minimally invasive percutaneous plating with the PHILOS offers a valid option in the treatment of proximal humeral shaft fractures with comparable rates of nonunion and lower rates of radial neuropathy compared with open procedures. Furthermore, the results indicate that this method is associated with lower rates of wound infection and a shorter stay in the hospital for the patient. Level of evidence: Level IV, Case Series, Treatment Study. (C) 2012 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:1056 / 1063
页数:8
相关论文
共 50 条
  • [1] Minimally invasive plating osteosynthesis of proximal humeral shaft fractures with long PHILOS plates
    Brunner, A.
    Thormann, S.
    Babst, R.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2012, 24 (4-5): : 302 - 311
  • [2] Proximal humeral internal locking system (PHILOS) for the treatment of proximal humeral fractures
    Charalambous, C. P.
    Siddique, I.
    Valluripalli, K.
    Kovacevic, M.
    Panose, P.
    Srinivasan, M.
    Marynissen, H.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2007, 127 (03) : 205 - 210
  • [3] Proximal humeral internal locking system (PHILOS) for the treatment of proximal humeral fractures
    C. P. Charalambous
    I. Siddique
    K. Valluripalli
    M. Kovacevic
    P. Panose
    M. Srinivasan
    H. Marynissen
    Archives of Orthopaedic and Trauma Surgery, 2007, 127 : 205 - 210
  • [4] Minimally invasive percutaneous osteosynthesis for proximal humeral shaft fractures with the PHILOS through the deltopectoral approach
    Zu-Bin Zhou
    You-Shui Gao
    Ming-Jie Tang
    Yu-Qiang Sun
    Chang-Qing Zhang
    International Orthopaedics, 2012, 36 : 2341 - 2345
  • [5] Minimally invasive percutaneous osteosynthesis for proximal humeral shaft fractures with the PHILOS through the deltopectoral approach
    Zhou, Zu-Bin
    Gao, You-Shui
    Tang, Ming-Jie
    Sun, Yu-Qiang
    Zhang, Chang-Qing
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (11) : 2341 - 2345
  • [6] Anterior minimally invasive plating osteosynthesis using reversed proximal humeral internal locking system plate for distal humeral shaft fractures
    Jitprapaikulsarn, Surasak
    Neti, Nutdanai
    Thremthakanpon, Witoon
    Gromprasit, Arthit
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (08): : 1515 - 1521
  • [7] Anterior minimally invasive plating osteosynthesis using reversed proximal humeral internal locking system plate for distal humeral shaft fractures
    Surasak Jitprapaikulsarn
    Nutdanai Neti
    Witoon Thremthakanpon
    Arthit Gromprasit
    European Journal of Orthopaedic Surgery & Traumatology, 2020, 30 : 1515 - 1521
  • [8] Complications and Outcomes of Minimally Invasive Percutaneous Plating for Proximal Humeral Fractures
    Park, Jin
    Jeong, Seong Yup
    CLINICS IN ORTHOPEDIC SURGERY, 2014, 6 (02) : 146 - 152
  • [9] Does Proximal Humerus Inter Locking System (PHILOS) Plating Provide a Good Functional Outcome in Proximal Humerus Fractures?
    Ethiraj, Prabhu
    Venkataraman, Sagar
    Karthik, S. J.
    Shanthappa, Arun H.
    Agarawal, Sandesh
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (06)
  • [10] The results of internal fixation of proximal humeral fractures with the PHILOS locking plate
    Korkmaz, Mehmet Fatih
    Aksu, Neslihan
    Goegus, Abdullah
    Debre, Muersel
    Kara, Ayhan Nedim
    Isiklar, Zekeriya Ugur
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2008, 42 (02) : 97 - 105