Energy Consumption and Internal Distribution in Activated Sludge Wastewater Treatment Plants of Greece

被引:64
|
作者
Siatou, Alexandra [1 ]
Manali, Anthoula [1 ]
Gikas, Petros [1 ]
机构
[1] Tech Univ Crete, Sch Environm Engn, Design Environm Proc Lab, Khania 73100, Greece
关键词
WWTP; energy consumption; energy assessment; aeration tank; activated sludge; EFFICIENCY;
D O I
10.3390/w12041204
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The high-energy consumption of wastewater treatment plants (WWTPs) is a crucial issue for municipalities worldwide. Most WWTPs in Greece operate as extended aeration plants, which results in high operational costs due to high energy needs. The present study investigated the energy requirements of 17 activated sludge WWTPs in Greece, serving between 1100-56,000 inhabitants (population equivalent, PE), with average daily incoming flowrates between 300-27,300 m(3)/d. The daily wastewater production per inhabitant was found to lie between 0.052 m(3)/PE.d and 0.426 m(3)/PE.d, with average volume of 0.217 +/- 0.114 m(3)/PE.d. The electric energy consumption per volume unit (E-Q (kWh/m(3))) was between 0.128-2.280 kWh/m(3) (average 0.903 +/- 0.509 kWh/m(3)) following a near logarithmic descending correlation with the average incoming flowrate (Q(av)) (E-Q = 0.294/nQ(av) + 3.1891; R-2 = 0.5337). A similar relationship was found between the daily electric energy requirements for wastewater treatment per inhabitant (E-PE (kWh/PE.d)) as a function of PE, which varied from 0.041-0.407 kWh/PE.d (average 0.167 +/- 0.101 kWh/PE.d)) (E-PE = 0.073ln(PE) + 0.8425; R-2 = 0.6989). Similarly, the daily energy cost per inhabitant (E-(sic)/PE ((sic)/PE.d)) as a function of PE and the electric energy cost per wastewater volume unit (E-(sic)/V ((sic)/m(3))) as a function of average daily flow (Q(av)) were found to follow near logarithmic trends (E-(sic)/PE = 0.013ln(PE) + 0.1473; R-2 = 0.6388, and E-(sic)/V = 0.052lnQ(av) + 0.5151; R-2 = 0.6359), respectively), with E-(sic)/PE varying between 0.005-0.073 (sic)/PE.d (average 0.024 +/- 0.019 (sic)/PE.d) and E-(sic)/V between 0.012-0.291 (sic)/m(3) (average 0.111 +/- 0.077 (sic)/m(3)). Finally, it was calculated that, in an average WWTP, the aeration process is the main energy sink, consuming about 67.2% of the total electric energy supply to the plant. The large variation of energy requirements per inlet volume unit and per inhabitant served, indicate that there is large ground for improving the performance of the WWTPs, with respect to energy consumption.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] PERFORMANCE OF ACTIVATED SLUDGE TREATMENT PLANTS
    POEPEL, F
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1962, 34 (03): : 243 - 243
  • [42] AERATION CONTROL FOR REDUCING ENERGY-CONSUMPTION IN SMALL ACTIVATED-SLUDGE PLANTS
    CLIFFT, RC
    ANDREWS, JF
    WATER SCIENCE AND TECHNOLOGY, 1981, 13 (10) : 371 - 379
  • [43] Application of activated sludge for odor control in wastewater treatment plants: Approaches, advances and outlooks
    Fan, Fuqiang
    Xu, Ronghua
    Wang, Depeng
    Meng, Fangang
    WATER RESEARCH, 2020, 181
  • [44] AN EFFICIENT ACTIVATED SLUDGE MODEL FOR OPERATOR SUPPORT IN PAPER MILL WASTEWATER TREATMENT PLANTS
    Cadet, Catherine
    Guillet, Agnes
    Aurousseau, Marc
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2015, 14 (05): : 1111 - 1123
  • [45] Characterizing hydrocyclone performance for grit removal from wastewater treatment activated sludge plants
    Mansour-Geoffrion, Majdala
    Dold, Peter L.
    Lamarre, Daniel
    Gadbois, Alain
    Deleris, Stephane
    Comeau, Yves
    MINERALS ENGINEERING, 2010, 23 (04) : 359 - 364
  • [46] A technique for normalizing the operation of biological wastewater treatment plants during the bulking of activated sludge
    Kravchenko, A. V.
    Zalevskii, V. S.
    JOURNAL OF WATER CHEMISTRY AND TECHNOLOGY, 2009, 31 (05) : 334 - 340
  • [47] Regression Modeling of Ozonation Process in Wastewater Treatment Plants for Reduction of Waste Activated Sludge
    Richardson, Ege Egemen
    Hanson, Adrian Thomas
    OZONE-SCIENCE & ENGINEERING, 2014, 36 (05) : 451 - 464
  • [48] Communities of ammonia oxidizing bacteria in activated sludge of various wastewater treatment plants in Beijing
    Wang, Xiaohui
    Wen, Xianghua
    JOURNAL OF BIOTECHNOLOGY, 2008, 136 : S610 - S610
  • [49] Ignored fungal community in activated sludge wastewater treatment plants: diversity and altitudinal characteristics
    Lihua Niu
    Yi Li
    Lingling Xu
    Peifang Wang
    Wenlong Zhang
    Chao Wang
    Wei Cai
    Linqiong Wang
    Environmental Science and Pollution Research, 2017, 24 : 4185 - 4193
  • [50] Analysis of Bacterial Community Structure of Activated Sludge from Wastewater Treatment Plants in Winter
    Xu, Shuang
    Yao, Junqin
    Ainiwaer, Meihaguli
    Hong, Ying
    Zhang, Yanjiang
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018