Energy Consumption and Internal Distribution in Activated Sludge Wastewater Treatment Plants of Greece

被引:64
|
作者
Siatou, Alexandra [1 ]
Manali, Anthoula [1 ]
Gikas, Petros [1 ]
机构
[1] Tech Univ Crete, Sch Environm Engn, Design Environm Proc Lab, Khania 73100, Greece
关键词
WWTP; energy consumption; energy assessment; aeration tank; activated sludge; EFFICIENCY;
D O I
10.3390/w12041204
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The high-energy consumption of wastewater treatment plants (WWTPs) is a crucial issue for municipalities worldwide. Most WWTPs in Greece operate as extended aeration plants, which results in high operational costs due to high energy needs. The present study investigated the energy requirements of 17 activated sludge WWTPs in Greece, serving between 1100-56,000 inhabitants (population equivalent, PE), with average daily incoming flowrates between 300-27,300 m(3)/d. The daily wastewater production per inhabitant was found to lie between 0.052 m(3)/PE.d and 0.426 m(3)/PE.d, with average volume of 0.217 +/- 0.114 m(3)/PE.d. The electric energy consumption per volume unit (E-Q (kWh/m(3))) was between 0.128-2.280 kWh/m(3) (average 0.903 +/- 0.509 kWh/m(3)) following a near logarithmic descending correlation with the average incoming flowrate (Q(av)) (E-Q = 0.294/nQ(av) + 3.1891; R-2 = 0.5337). A similar relationship was found between the daily electric energy requirements for wastewater treatment per inhabitant (E-PE (kWh/PE.d)) as a function of PE, which varied from 0.041-0.407 kWh/PE.d (average 0.167 +/- 0.101 kWh/PE.d)) (E-PE = 0.073ln(PE) + 0.8425; R-2 = 0.6989). Similarly, the daily energy cost per inhabitant (E-(sic)/PE ((sic)/PE.d)) as a function of PE and the electric energy cost per wastewater volume unit (E-(sic)/V ((sic)/m(3))) as a function of average daily flow (Q(av)) were found to follow near logarithmic trends (E-(sic)/PE = 0.013ln(PE) + 0.1473; R-2 = 0.6388, and E-(sic)/V = 0.052lnQ(av) + 0.5151; R-2 = 0.6359), respectively), with E-(sic)/PE varying between 0.005-0.073 (sic)/PE.d (average 0.024 +/- 0.019 (sic)/PE.d) and E-(sic)/V between 0.012-0.291 (sic)/m(3) (average 0.111 +/- 0.077 (sic)/m(3)). Finally, it was calculated that, in an average WWTP, the aeration process is the main energy sink, consuming about 67.2% of the total electric energy supply to the plant. The large variation of energy requirements per inlet volume unit and per inhabitant served, indicate that there is large ground for improving the performance of the WWTPs, with respect to energy consumption.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Fate of pathogenic microorganisms and indicators in secondary activated sludge wastewater treatment plants
    Wen, Qinxue
    Tutuka, Candani
    Keegan, Alexandra
    Jin, Bo
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2009, 90 (03) : 1442 - 1447
  • [22] Development of an operational performance indicator system for activated sludge wastewater treatment plants
    Gordon, Glenn T.
    McCann, Brian P.
    WATER PRACTICE AND TECHNOLOGY, 2015, 10 (04): : 860 - 871
  • [23] Adsorption characteristics of sulfide onto the activated sludge of municipal wastewater treatment plants
    Xi, J.-Y. (xijinying@tsinghua.edu.cn), 1600, Chinese Society for Environmental Sciences (34):
  • [24] A knowledge base for wastewater treatment plants: The case of an activated-sludge facility
    Boo, OC
    Aguilar, AS
    EXPERT SYSTEMS WITH APPLICATIONS, 1998, 14 (1-2) : 53 - 61
  • [25] Diversity of Activated Sludge Microbial Community Structure in Different Wastewater Treatment Plants
    Guo, Feng
    Wang, Qing
    Zhao, Jiaying
    Wang, Yilong
    Zhu, Xinfeng
    Mao, Yanli
    Wu, Junfeng
    Song, Zhongxian
    Hu, Hongwei
    Peng, Wei
    Liu, Biao
    BIOLOGY BULLETIN, 2023, 50 (03) : 329 - 337
  • [26] Occurrence and removal of bisphenol analogues in wastewater treatment plants and activated sludge bioreactor
    Qian, Yiguang
    Jia, Xiaofan
    Ding, Tengda
    Yang, Mengting
    Yang, Bo
    Li, Juying
    SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 758
  • [27] Fate of LAS in activated sludge wastewater treatment plants: A model verification study
    Feijtel, T
    Vits, H
    MurraySmith, R
    vanWijk, R
    Koch, V
    Schroder, R
    Birch, R
    TenBerge, W
    CHEMOSPHERE, 1996, 32 (07) : 1413 - 1426
  • [28] Community Composition and Function of Bacteria in Activated Sludge of Municipal Wastewater Treatment Plants
    Xie, Ning
    Zhong, Liping
    Ouyang, Liao
    Xu, Wang
    Zeng, Qinghuai
    Wang, Keju
    Zaynab, Madiha
    Chen, Huirong
    Xu, Fangfang
    Li, Shuangfei
    WATER, 2021, 13 (06)
  • [29] Energy Consumption and Carbon Footprint of Greek Wastewater Treatment Plants
    Goliopoulos, Nikos
    Mamais, Daniel
    Noutsopoulos, Constantinos
    Dimopoulou, Argyri
    Kounadis, Christos
    WATER, 2022, 14 (03)
  • [30] RECIPIENT POLLUTION CAUSED BY SMALL DOMESTIC WASTEWATER TREATMENT PLANTS WITH ACTIVATED SLUDGE
    Klimsa, Lukas
    Melcakova, Iva
    Novakova, Jana
    Bartkova, Magdalena
    Hlavac, Adam
    Krakovska, Aneta
    Dombek, Vaclav
    Andras, Peter
    CARPATHIAN JOURNAL OF EARTH AND ENVIRONMENTAL SCIENCES, 2020, 15 (01): : 19 - 25