Upgrade of the CMS hadron calorimeter for an upgraded LHC

被引:0
|
作者
Anderson, Jacob [1 ]
机构
[1] Fermilab Natl Accelerator Lab, Batavia, IL 60510 USA
关键词
D O I
10.1088/1742-6596/404/1/012019
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The CMS barrel and endcap hadron calorimeters (Hcal) upgrading the current photo-sensors are hybrid photodiodes (HPDs) to meet the demands of the upgraded luminosity of the LHC. A key aspect of the Hcal upgrade is to add longitudinal segmentation to improve background rejection, energy resolution, and electron isolation at L1 trigger. The increased segmentation can be achieved by replacing the HPD's with multi-pixel Geiger-mode avalanche photodiodes. The upgraded electronics are required to operate in a harsh environment and are constrained by the existing infrastructure. The proposed solutions span from chip level to system level. They include the development of a new ADC ASIC, the design and testing of higher speed transmitters to handle the increased data volume, the evaluation and use of circuits from other developments, evaluation of commercial FPGAs, better thermal design and improvements in the overall architecture.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Hadron Production at LHC with the CMS Detector
    Rougny, Romain
    PROGRESS OF THEORETICAL PHYSICS SUPPLEMENT, 2012, (193): : 127 - 131
  • [42] Modernization of the CMS Hadron Calorimetry at the LHC
    P. D. Bunin
    Physics of Particles and Nuclei, 2024, 55 : 109 - 115
  • [43] Performance of the CMS pixel detector at an upgraded LHC
    Horisberger, R.
    Kotlinski, D.
    Rohe, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (01): : 289 - 293
  • [44] Modernization of the CMS Hadron Calorimetry at the LHC
    Bunin, P. D.
    PHYSICS OF PARTICLES AND NUCLEI, 2024, 55 (01) : 109 - 115
  • [45] THE PERFORMANCE OF THE CMS HADRON CALORIMETER WITH COSMIC MUONS
    Hagopian, Vasken
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2010, 5 : 362 - 366
  • [46] UPDATE ON THE HADRON CALORIMETER OF THE CMS EXPERIMENT AT CERN
    Hagopian, Vasken
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 331 - 335
  • [47] Calibration of the CMS hadron calorimeter in Run 2
    Chadeeva, M.
    Lychkovskaya, N.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [48] CMS Calorimeter Trigger Phase I upgrade
    Klabbers, P.
    Gorski, T.
    Bachtis, M.
    Compton, K.
    Dasu, S.
    Farmahini-Farahani, A.
    Fobes, R.
    Gregerson, A.
    Grothe, M.
    Ross, I.
    Seemuth, D.
    Schulte, M.
    Smith, W. H.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [49] Design options for the upgrade of the CMS electromagnetic calorimeter
    Paramatti, R.
    NUCLEAR AND PARTICLE PHYSICS PROCEEDINGS, 2016, 273 : 995 - 1001
  • [50] The Compact Muon Solenoid (CMS) Hadron Calorimeter
    Hagopian, V
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 1999, 78 : 182 - 185