Upgrade of the CMS hadron calorimeter for an upgraded LHC

被引:0
|
作者
Anderson, Jacob [1 ]
机构
[1] Fermilab Natl Accelerator Lab, Batavia, IL 60510 USA
关键词
D O I
10.1088/1742-6596/404/1/012019
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The CMS barrel and endcap hadron calorimeters (Hcal) upgrading the current photo-sensors are hybrid photodiodes (HPDs) to meet the demands of the upgraded luminosity of the LHC. A key aspect of the Hcal upgrade is to add longitudinal segmentation to improve background rejection, energy resolution, and electron isolation at L1 trigger. The increased segmentation can be achieved by replacing the HPD's with multi-pixel Geiger-mode avalanche photodiodes. The upgraded electronics are required to operate in a harsh environment and are constrained by the existing infrastructure. The proposed solutions span from chip level to system level. They include the development of a new ADC ASIC, the design and testing of higher speed transmitters to handle the increased data volume, the evaluation and use of circuits from other developments, evaluation of commercial FPGAs, better thermal design and improvements in the overall architecture.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] The CMS crystal calorimeter for the LHC
    Zach, F
    HIGH ENERGY PHYSICS, VOLS I AND II, 2001, : 1254 - 1256
  • [32] Performance of the CMS-Forward (HF) Calorimeter in the 2010 LHC Run and the Upgrade Plans
    Gulmez, E.
    ASTROPARTICLE, PARTICLE, SPACE PHYSICS AND DETECTORS FOR PHYSICS APPLICATIONS, 2012, 7 : 771 - 774
  • [33] Triggering on electrons, jets and tau leptons with the CMS upgraded calorimeter trigger for the LHC RUN II
    Zabi, A.
    Beaudette, F.
    Cadamuro, L.
    Mastrolorenzo, L.
    Romanteau, T.
    Sauvan, J. B.
    Strebler, T.
    Marrouche, J.
    Wardle, N.
    Aggleton, R.
    Ball, F.
    Brooke, J.
    Newbold, D.
    Paramesvaran, S.
    Smith, D.
    Baber, M.
    Bundock, A.
    Citron, M.
    Elwood, A.
    Hall, G.
    Iles, G.
    Laner, C.
    Penning, B.
    Rose, A.
    Tapper, A.
    Durkin, T.
    Harder, K.
    Harper, S.
    Shepherd-Themistocleous, C.
    Thea, A.
    Williams, T.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [34] Upgrade of the CMS electromagnetic calorimeter for precision timing and energy measurements at the High Luminosity LHC
    Argiro, S.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (04):
  • [35] Design of the CMS calorimeter trigger upgrade from Phase I to Phase II of the LHC
    Zabi, Alexandre
    18TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN PARTICLE PHYSICS (CALOR2018), 2019, 1162
  • [36] Silicon photomultipliers for the CMS hadron calorimeter
    Freeman, Jim
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 617 (1-3): : 393 - 395
  • [37] Physics capabilities of the CMS hadron calorimeter
    Wu, WM
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 2000, : 394 - 403
  • [38] Calibration of the CMS Electromagnetic Calorimeter at the LHC
    Leslie, D. E.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1196 - 1198
  • [39] Performance of the CMS Electromagnetic Calorimeter at the LHC
    Della Ricca, Giuseppe
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 1476 - 1479
  • [40] Prospects for a precision timing upgrade of the CMS PbWO crystal electromagnetic calorimeter for the HL-LHC
    Massironi, A.
    JOURNAL OF INSTRUMENTATION, 2018, 13