A dosimetric leaf-setting strategy for shaping radiation fields using a multileaf collimator

被引:6
|
作者
Ma, LJ [1 ]
Yu, C [1 ]
Sarfaraz, M [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Radiat Oncol, Baltimore, MD 21201 USA
关键词
multileaf collimator; Cerrobend block; radiation field; leaf-setting; x-ray dosimetry;
D O I
10.1118/1.598961
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A dosimetric leaf-setting strategy of using multileaf collimators (MLC) for shaping radiation fields has been developed. Existing MLC leaf-setting strategies are all based upon geometric criteria. This new approach, however, matches a prescribed field contour with a MLC using clinically consistent dosimetric criteria. The leaf positions are determined using an iterative optimization algorithm. An empirical dose model was developed to compare the dosimetric-based leaf-setting strategy with the geometric-based leaf-setting strategies. Differences up to half a centimeter in the leaf positions and isodose lines were found between setting the MLC geometrically and setting the MLC dosimetrically. The dosimetric leaf-setting strategy provides the ability to achieve better dose conformation for a clinically desired isodose line. Since the desired isodose line that covers a treatment volume is typically higher than 50% of the maximum dose, the scalloping effects due to the finite leaf width at the leaf edge or 50% isodose lines are much reduced. Another benefit of the dosimetric leaf-setting is that it separates the leaf-setting process from the treatment planning process, and this frees the treatment planning vendors from developing detailed dose models for various existing types and future upgrades of MLC systems. (C) 2000 American Association of Physicists in Medicine.
引用
收藏
页码:972 / 977
页数:6
相关论文
共 50 条
  • [31] Fundamental Dosimetric Characterization of TLD-100: A Preliminary Study of Radiotherapy Dose Audit with Irregular Multileaf Collimator Fields
    Ab Rahim, Rohaizah Mohamad
    Fadzil, Muhammad Safwan Ahmad
    Azmi, Nor Aniza
    Sabarudin, Akmal
    Saparudin, Abdul Khaliq Mohd
    Hamsan, Siti Khadijah
    Dollah, Mohd Taufik
    Min, Ung Ngie
    Noor, Noramaliza Mohd
    JURNAL FIZIK MALAYSIA, 2023, 44 (01): : 10052 - 10060
  • [32] Optimization of Leaf Sequence for Multileaf Collimator in Lumbar Vertebrae IMRT Using Multiple Algorithms
    Jia, J.
    Lin, H.
    Chow, J.
    MEDICAL PHYSICS, 2017, 44 (06) : 2900 - 2900
  • [33] A simple method for determining dosimetric leaf gap with cross-field dose width for rounded leaf-end multileaf collimator systems
    Chih-Yuan Lin
    An-Cheng Shiau
    Jin-Huei Ji
    Chia-Jung Lee
    Ti-Hao Wang
    Shu-Hui Hsu
    Ji-An Liang
    Radiation Oncology, 13
  • [34] A simple method for determining dosimetric leaf gap with cross-field dose width for rounded leaf-end multileaf collimator systems
    Lin, Chih-Yuan
    Shiau, An-Cheng
    Ji, Jin-Huei
    Lee, Chia-Jung
    Wang, Ti-Hao
    Hsu, Shu-Hui
    Liang, Ji-An
    RADIATION ONCOLOGY, 2018, 13
  • [35] Dosimetric Comparison of a Frameless Robotic Radiosurgery System with Multileaf and Fixed Collimator for Stereotactic Body Radiation Therapy in Spine Metastasis
    Baek, J. G.
    Woo, J. Y.
    Kim, S. Y.
    Kim, M. J.
    Park, K. S.
    Jeong, T. S.
    Park, R. H.
    Kim, J. H.
    Hee, C. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E636 - E636
  • [36] Dosimetric effect of respiratory motion prediction error on dynamic multileaf collimator based 4D radiation delivery
    Vedam, S
    Docef, A
    Keall, P
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S230 - S230
  • [37] Dosimetric Impact of Multileaf Collimator Leaf Width On Stereotactic Radiosurgery (SRS) RapidArc Treatment Plans for Single and Multiple Brain Metastases
    Hossain, S.
    Keeling, V.
    Ahmad, S.
    Algan, O.
    MEDICAL PHYSICS, 2015, 42 (06) : 3409 - 3409
  • [38] Dosimetric impact of multileaf collimator leaf width according to sophisticated grade of technique in the IMRT and VMAT planning for pituitary adenoma lesion
    Chae, Soo-Min
    Lee, Ki Woong
    Son, Seok Hyun
    ONCOTARGET, 2016, 7 (47) : 78119 - 78126
  • [39] Dosimetric Impact of Multileaf Collimator Leaf Width On Single and multiple Isocenter Stereotactic IMRT Treatment Plans for multiple Brain Tumors
    Giem, J.
    Algan, O.
    Ahmad, S.
    Ali, I.
    Young, J.
    Hossain, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 324 - 324
  • [40] Dosimetric Benefit of Using Real-Time Multileaf Collimator Tracking to Compensate for Intrafractional Lung Tumor Deformations
    Menten, M. J.
    Glitzner, M.
    Bertholet, J.
    Nill, S.
    Raaymakers, B. W.
    Oelfke, U.
    MEDICAL PHYSICS, 2018, 45 (06) : E646 - E646