A dosimetric leaf-setting strategy for shaping radiation fields using a multileaf collimator

被引:6
|
作者
Ma, LJ [1 ]
Yu, C [1 ]
Sarfaraz, M [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Radiat Oncol, Baltimore, MD 21201 USA
关键词
multileaf collimator; Cerrobend block; radiation field; leaf-setting; x-ray dosimetry;
D O I
10.1118/1.598961
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A dosimetric leaf-setting strategy of using multileaf collimators (MLC) for shaping radiation fields has been developed. Existing MLC leaf-setting strategies are all based upon geometric criteria. This new approach, however, matches a prescribed field contour with a MLC using clinically consistent dosimetric criteria. The leaf positions are determined using an iterative optimization algorithm. An empirical dose model was developed to compare the dosimetric-based leaf-setting strategy with the geometric-based leaf-setting strategies. Differences up to half a centimeter in the leaf positions and isodose lines were found between setting the MLC geometrically and setting the MLC dosimetrically. The dosimetric leaf-setting strategy provides the ability to achieve better dose conformation for a clinically desired isodose line. Since the desired isodose line that covers a treatment volume is typically higher than 50% of the maximum dose, the scalloping effects due to the finite leaf width at the leaf edge or 50% isodose lines are much reduced. Another benefit of the dosimetric leaf-setting is that it separates the leaf-setting process from the treatment planning process, and this frees the treatment planning vendors from developing detailed dose models for various existing types and future upgrades of MLC systems. (C) 2000 American Association of Physicists in Medicine.
引用
收藏
页码:972 / 977
页数:6
相关论文
共 50 条
  • [21] Beam shaping using an ultrahigh vacuum multileaf collimator and emittance exchange beamline
    Majernik, N.
    Andonian, G.
    Lynn, W.
    Kim, S.
    Lorch, C.
    Roussel, R.
    Doran, S.
    Wisniewski, E.
    Whiteford, C.
    Piot, P.
    Power, J.
    Rosenzweig, J. B.
    PHYSICAL REVIEW ACCELERATORS AND BEAMS, 2023, 26 (02)
  • [22] Dosimetric assessment of the field abutment region in head and neck treatments using a multileaf collimator
    Abdel-Hakim, K
    Nishimura, T
    Takaih, M
    Suzuki, S
    Sakahara, H
    STRAHLENTHERAPIE UND ONKOLOGIE, 2003, 179 (05) : 312 - 319
  • [23] Configuration options for intensity-modulated radiation therapy using multiple static fields shaped by a multileaf collimator
    Webb, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (02): : 241 - 260
  • [24] A simple dosimetric approach to spatially fractionated GRID radiation therapy using the multileaf collimator for treatment of breast cancers in the prone position
    Murphy, Natasha L.
    Philip, Rino
    Wozniak, Matt
    Lee, Brian H.
    Donnelly, Eric D.
    Zhang, Hualin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (11): : 105 - 114
  • [25] Verification of multileaf collimator leaf positions using an electronic portal imaging device
    Samant, SS
    Zheng, W
    Parra, NA
    Chandler, J
    Gopal, A
    Wu, J
    Jain, J
    Zhu, YP
    Sontag, M
    MEDICAL PHYSICS, 2002, 29 (12) : 2900 - 2912
  • [26] Dosimetric verification of modulated electron radiotherapy delivered using a photon multileaf collimator for intact breasts
    Jin, L.
    Ma, C-M
    Fan, J.
    Eldib, A.
    Price, R. A.
    Chen, L.
    Wang, L.
    Chi, Z.
    Xu, Q.
    Sherif, M.
    Li, J. S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (21): : 6009 - 6025
  • [27] Investigation of the impact of leaf design on the radiation leakage through a multileaf collimator for use in proton radiotherapy
    Ainsley, C.
    Avery, S.
    Maughan, R.
    McDonough, J.
    Bloch, P.
    Goulart, D.
    Ingram, M.
    MEDICAL PHYSICS, 2007, 34 (06) : 2590 - 2590
  • [28] A Novel Method to Automate the Optimization of Multileaf Collimator Transmission and Dosimetric Leaf Gap Parameters for Eclipse Treatment Planning System
    DiCostanzo, D.
    Ayan, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E571 - E571
  • [29] The effect of gantry and collimator angles on leaf limited velocity and position in dynamic multileaf collimator intensity-modulated radiation therapy
    Okumura, M.
    Obata, Y.
    Shimomura, K.
    Tamura, M.
    Nishimura, Y.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (11): : 3101 - 3113
  • [30] Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors
    Klein, David M.
    Tailor, Ramesh C.
    Archambault, Louis
    Wang, Lilie
    Therriault-Proulx, Francois
    Beddar, A. Sam
    MEDICAL PHYSICS, 2010, 37 (10) : 5541 - 5549