A dosimetric leaf-setting strategy for shaping radiation fields using a multileaf collimator

被引:6
|
作者
Ma, LJ [1 ]
Yu, C [1 ]
Sarfaraz, M [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Radiat Oncol, Baltimore, MD 21201 USA
关键词
multileaf collimator; Cerrobend block; radiation field; leaf-setting; x-ray dosimetry;
D O I
10.1118/1.598961
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A dosimetric leaf-setting strategy of using multileaf collimators (MLC) for shaping radiation fields has been developed. Existing MLC leaf-setting strategies are all based upon geometric criteria. This new approach, however, matches a prescribed field contour with a MLC using clinically consistent dosimetric criteria. The leaf positions are determined using an iterative optimization algorithm. An empirical dose model was developed to compare the dosimetric-based leaf-setting strategy with the geometric-based leaf-setting strategies. Differences up to half a centimeter in the leaf positions and isodose lines were found between setting the MLC geometrically and setting the MLC dosimetrically. The dosimetric leaf-setting strategy provides the ability to achieve better dose conformation for a clinically desired isodose line. Since the desired isodose line that covers a treatment volume is typically higher than 50% of the maximum dose, the scalloping effects due to the finite leaf width at the leaf edge or 50% isodose lines are much reduced. Another benefit of the dosimetric leaf-setting is that it separates the leaf-setting process from the treatment planning process, and this frees the treatment planning vendors from developing detailed dose models for various existing types and future upgrades of MLC systems. (C) 2000 American Association of Physicists in Medicine.
引用
收藏
页码:972 / 977
页数:6
相关论文
共 50 条
  • [1] Determining the optimal dosimetric leaf gap setting for rounded leaf-end multileaf collimator systems by simple test fields
    Yao, Weiguang
    Farr, Jonathan B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (04): : 65 - 77
  • [2] A method for determining dosimetric leaf separation of a multileaf collimator
    Kulmala, A.
    Rintala, A.
    Pennanen, J.
    Tenhunen, M.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S749 - S750
  • [3] OPTIMIZATION OF LEAF POSITIONS WHEN SHAPING A RADIATION-FIELD WITH A MULTILEAF COLLIMATOR
    XU, CX
    YAN, D
    DU, MN
    ZHOU, S
    VERHEY, LJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (02): : 305 - 308
  • [4] An optimized leaf-setting algorithm for beam intensity modulation using dynamic multileaf collimators
    Ma, LJ
    Boyer, AL
    Xing, L
    Ma, CM
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (06): : 1629 - 1643
  • [5] Dosimetric evaluation of the conformation of the multileaf collimator to irregularly shaped fields
    Frazier, A
    Du, M
    Wong, J
    Vicini, F
    Taylor, R
    Yu, C
    Matter, R
    Martinez, A
    Yan, D
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05): : 1229 - 1238
  • [6] Evaluation of dosimetric effect of leaf position in a radiation field of an 80-leaf multileaf collimator fitted to the LINAC head as a tertiary collimator
    Kehwar, Than S.
    Bhardwaj, Anup K.
    Chakarvarti, Shiv K.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2006, 7 (03): : 43 - 54
  • [7] Dosimetric study of grid therapy using a multileaf collimator
    Ha, J
    Zhang, G
    Naqvi, S
    Regine, W
    Yu, C
    MEDICAL PHYSICS, 2005, 32 (06) : 2021 - 2021
  • [8] Dosimetric leaf gap and leaf trailing effect in a double-stacked multileaf collimator
    Hernandez, Victor
    Saez, Jordi
    Angerud, Agnes
    Cayez, Romain
    Khamphan, Catherine
    Nguyen, Daniel
    Vieillevigne, Laure
    Feygelman, Vladimir
    MEDICAL PHYSICS, 2021, 48 (07) : 3413 - 3424
  • [9] Dosimetric characteristics of an electron multileaf collimator for modulated electron radiation therapy
    Eldib, Ahmed A.
    ElGohary, Mohamed I.
    Fan, Jiajin
    Jin, Lihui
    Li, Jinsheng
    Ma, C-M Charlie
    Elsherbini, Nader A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (02): : 5 - 22
  • [10] A Simple Method for Determining Dosimetric Leaf Gap for Rounded Leaf-End Multileaf Collimator Systems
    Shiau, A.
    Lin, C.
    Ji, J.
    Liang, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E302 - E303