Passive cavitation mapping using dual apodization with cross-correlation in ultrasound therapy monitoring

被引:7
|
作者
Lu, Shukuan [1 ]
Yu, Xianbo [1 ]
Li, Renyan [1 ]
Zong, Yujin [1 ]
Wan, Mingxi [1 ]
机构
[1] Xi An Jiao Tong Univ, Key Lab Biomed Informat Engn, Minist Educ, Dept Biomed Engn,Sch Life Sci & Technol, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Cavitation activity; Passive acoustic mapping; Dual apodization with cross-correlation; Therapy monitoring; INTENSITY FOCUSED ULTRASOUND; INERTIAL CAVITATION; HIFU; MICROBUBBLES; HISTOTRIPSY; DRUG; SUPPRESSION; DISRUPTION; ABLATION; DELIVERY;
D O I
10.1016/j.ultsonch.2019.02.020
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Recently, passive acoustic mapping (PAM) has been successfully applied for dynamic monitoring of ultrasound therapy by beamforming acoustic emissions of cavitation activity during ultrasound exposure. The most widely used PAM algorithm in the literature is time exposure acoustics (TEA), which is a standard delay, sum, and integrate algorithm. However, it results in large point spread function (PSF) and serious imaging artifacts for the case where a narrow-aperture receiving array such as a standard B-mode linear array is used, therefore degrading the quality of cavitation image. To address these challenges, in this paper, we proposed a novel PAM algorithm namely dual apodization with cross-correlation (DAX)-based TEA, in which DAX was originally used as a reconstruction algorithm in medical ultrasound imaging. In the proposed algorithm, two sets of signals were beamformed by two receive apodization functions with alternating elements enabled, and the cross-correlation coefficient of the two signals served as a weighting factor that would be multiplied to the sum of the two signals. The performance of the proposed algorithm was tested on simulated channel data obtained using a multi-bubble model, and experiments were also performed in an in vitro vessel phantom with flowing microbubbles as cavitation nuclei. The reconstructed cavitation images were evaluated quantitatively using established quality metrics including full width at half maximum (FWHM), A(-6dB) area, and signal-to-noise ratio (SNR). The results suggested that the proposed algorithm significantly outperformed the conventionally used TEA algorithm. This work may have the potential of providing a useful tool for highly accurate localization of cavitation activity during ultrasound therapy.
引用
收藏
页码:18 / 31
页数:14
相关论文
共 50 条
  • [31] On the performance of the cross-correlation detector for passive radar applications
    Liu, Jun
    Li, Hongbin
    Himed, Braham
    SIGNAL PROCESSING, 2015, 113 : 32 - 37
  • [32] Analysis of Cross-Correlation Detector for Passive Radar Applications
    Liu, Jun
    Li, Hongbin
    Himed, Braham
    2015 IEEE INTERNATIONAL RADAR CONFERENCE (RADARCON), 2015, : 772 - 776
  • [33] Condition Monitoring Of Train Suspension Systems Using a Cross-correlation Technique
    Ren, Ning
    Fu, Min Yue
    2014 33RD CHINESE CONTROL CONFERENCE (CCC), 2014, : 3158 - 3163
  • [34] Aadaptive Imaging with Multi-Phase Apodization with Cross-correlation: Phantom and in vivo Results
    Shin, Junseob
    Yen, Jesse T.
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [35] Evaluation of Transducer Configurations for Ultrasound Cross-Correlation Flowmeters
    Vogt, M.
    Gevers, M.
    Musch, T.
    2014 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC) PROCEEDINGS, 2014, : 40 - 44
  • [36] Noise Analysis of Passive Sampling Mixers Using Auto- and Cross-Correlation Functions
    Heydari, Payam
    2021 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2021,
  • [37] Passive Sources and Diffracted Points Imaging Using Combinational Cross-Correlation Imaging Condition
    Yan, Tianfan
    Liu, Yike
    Zhang, Zhendong
    He, Bin
    Wang, Haiwei
    JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2025, 130 (01)
  • [38] CROSS-CORRELATION ANALYSER USING A PRBS
    WILSON, H
    ELECTRONIC ENGINEERING, 1969, 41 (495): : 66 - &
  • [39] Dual-beam incoherent cross-correlation spectroscopy
    Xia, K.-Q.
    Xin, Y.-B.
    Tong, P.
    Journal of the Optical Society of America A: Optics and Image Science, and Vision, 1995, 12 (07):
  • [40] NORMALIZED CROSS-CORRELATION USING SOFT
    Huhle, Benjamin
    Schairer, Timo
    Strasser, Wolfgang
    LNLA: 2009 INTERNATIONAL WORKSHOP ON LOCAL AND NON-LOCAL APPROXIMATION IN IMAGE PROCESSING, 2009, : 82 - +