Passive cavitation mapping using dual apodization with cross-correlation in ultrasound therapy monitoring

被引:7
|
作者
Lu, Shukuan [1 ]
Yu, Xianbo [1 ]
Li, Renyan [1 ]
Zong, Yujin [1 ]
Wan, Mingxi [1 ]
机构
[1] Xi An Jiao Tong Univ, Key Lab Biomed Informat Engn, Minist Educ, Dept Biomed Engn,Sch Life Sci & Technol, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Cavitation activity; Passive acoustic mapping; Dual apodization with cross-correlation; Therapy monitoring; INTENSITY FOCUSED ULTRASOUND; INERTIAL CAVITATION; HIFU; MICROBUBBLES; HISTOTRIPSY; DRUG; SUPPRESSION; DISRUPTION; ABLATION; DELIVERY;
D O I
10.1016/j.ultsonch.2019.02.020
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Recently, passive acoustic mapping (PAM) has been successfully applied for dynamic monitoring of ultrasound therapy by beamforming acoustic emissions of cavitation activity during ultrasound exposure. The most widely used PAM algorithm in the literature is time exposure acoustics (TEA), which is a standard delay, sum, and integrate algorithm. However, it results in large point spread function (PSF) and serious imaging artifacts for the case where a narrow-aperture receiving array such as a standard B-mode linear array is used, therefore degrading the quality of cavitation image. To address these challenges, in this paper, we proposed a novel PAM algorithm namely dual apodization with cross-correlation (DAX)-based TEA, in which DAX was originally used as a reconstruction algorithm in medical ultrasound imaging. In the proposed algorithm, two sets of signals were beamformed by two receive apodization functions with alternating elements enabled, and the cross-correlation coefficient of the two signals served as a weighting factor that would be multiplied to the sum of the two signals. The performance of the proposed algorithm was tested on simulated channel data obtained using a multi-bubble model, and experiments were also performed in an in vitro vessel phantom with flowing microbubbles as cavitation nuclei. The reconstructed cavitation images were evaluated quantitatively using established quality metrics including full width at half maximum (FWHM), A(-6dB) area, and signal-to-noise ratio (SNR). The results suggested that the proposed algorithm significantly outperformed the conventionally used TEA algorithm. This work may have the potential of providing a useful tool for highly accurate localization of cavitation activity during ultrasound therapy.
引用
收藏
页码:18 / 31
页数:14
相关论文
共 50 条
  • [21] Nonlinear ultrasound: Potential of the cross-correlation method for osseointegration monitoring
    Rivière, Jacques
    Haupert, Sylvain
    Laugier, Pascal
    Johnson, Paul A.
    Journal of the Acoustical Society of America, 2012, 132 (03):
  • [22] Monitoring holograms for therapeutic ultrasound using passive cavitation beamforming
    Lamothe, Nathalie
    Andres, Diana
    Carrion, Alicia
    Camarena, Francisco
    Pineda-Pardo, Jose A.
    Jimenez, Noe
    APPLIED ACOUSTICS, 2024, 224
  • [23] Robust Ultrasonic Reverberation Clutter Suppression Using Multi-Apodization with Cross-correlation
    Shin, Junseob
    Chen, Yu
    Nguyen, Man
    Yen, Jesse T.
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 543 - 546
  • [24] Performance Evaluation of Adaptive Imaging Based on Multiphase Apodization with Cross-correlation: A Pilot Study in Abdominal Ultrasound
    Shin, Junseob
    Chen, Yu
    Malhi, Harshawn
    Chen, Frank
    Yen, Jesse
    ULTRASONIC IMAGING, 2018, 40 (04) : 195 - 214
  • [25] Passive acoustic mapping of cavitation using eigenspace-based robust Capon beamformer in ultrasound therapy
    Lu, Shukuan
    Hu, Hong
    Yu, Xianbo
    Long, Jiangying
    Jing, Bowen
    Zong, Yujin
    Wan, Mingxi
    ULTRASONICS SONOCHEMISTRY, 2018, 41 : 670 - 679
  • [26] ARTIFACTS IN BLOOD VELOCITY ESTIMATION USING ULTRASOUND AND CROSS-CORRELATION
    JENSEN, JA
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1994, 32 (04) : S165 - S170
  • [27] Effects of Dual Apodization With Cross-Correlation on Tissue Harmonic and Pulse Inversion Harmonic Imaging in the Presence of Phase Aberration
    Shin, Junseob
    Yen, Jesse T.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (03) : 643 - 649
  • [28] A Low-Complexity Beamformer for Ultrasound Imaging Based on Sub-Beamformer and Multi-Apodization With Cross-Correlation
    Shen, Yue
    Wang, Ping
    Tong, Lin
    Chen, Jinghan
    Li, Qianwen
    Zhu, Jinchan
    Wang, Kunlin
    Zeng, Jingya
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (10): : 1551 - 1565
  • [29] Passive acoustic mapping utilizing optimal beamforming in ultrasound therapy monitoring
    Coviello, Christian
    Kozick, Richard
    Choi, James
    Gyoengy, Miklos
    Jensen, Carl
    Smith, Penny Probert
    Coussios, Constantin-C.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2015, 137 (05): : 2573 - 2585
  • [30] Dual Comb Electric Field Cross-Correlation
    Ferdous, Fahmida
    Huang, C. -B.
    Leaird, D. E.
    Weiner, A. M.
    2009 CONFERENCE ON LASERS AND ELECTRO-OPTICS AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2009), VOLS 1-5, 2009, : 1658 - +