Measuring cochlear duct length in Asian population: worth giving a thought!

被引:29
|
作者
Grover, Mohnish [1 ]
Sharma, Shitanshu [1 ]
Singh, Shashank Nath [1 ]
Kataria, Tanmaya [1 ]
Lakhawat, Rajendra Singh [1 ]
Sharma, Man Prakash [1 ]
机构
[1] SMS Med Coll & Hosp, Dept Otorhinolaryngol & Head Neck Surg, Jaipur 302004, Rajasthan, India
关键词
Cochlear duct length; Cochlear implantation;
D O I
10.1007/s00405-018-4868-9
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
The anatomy of the cochlea forms the basis for a successful cochlear implantation. Cochlear duct length (CDL) is defined as the length of the scala media as measured from the middle of the round window to helicotrema. Preoperative measurement of CDL is particularly important when precise intracochlear electrode array placement is desired. It can be done both histologically and radiologically. Preoperative high-resolution computed tomography (HRCT) scan which forms an integral part of cochlear implant workup is a useful tool to calculate CDL using 3D reconstructions. This study was done in SMS Medical College and Hospital, Jaipur, India, which is a tertiary care hospital and referral centre for cochlear implants. HRCT temporal bones of all children less than 6 years of age, with congenital bilateral severe-to-profound SNHL who were being worked up for cochlear implant were studied and analysed. 124 patients (56 females and 68 males) with hearing loss were evaluated for cochlear implantation. HRCT temporal bone of these patients was analysed and a variable A was measured which is defined as the linear measurement from the round window to the farthest point on the opposite wall of the cochlea on a reformatted CT scan slice. Mean of distance A for right ear of these patients was 8.10 mm (range 7.7-9.2 mm). Mean for the same in left ear of these patients was 8.14 mm (range 7.7-9.0 mm), giving an overall average of 8.12 mm. Using the formula, CDL = 4.16A-3.98, we calculated the length of cochlear duct. Mean cochlear duct length was 29.8 mm with a range from 28 to 34.3 mm. To the best of our knowledge, this is the first large sample study of cochlear length in population of this part of the world. A smaller cochlear length in this part of the world as compared to the Caucasian cochlear duct is a significant finding in understanding of the cochlear anatomy and physiology. It would also have great implications on the insertion depth in cochlear implantation.
引用
收藏
页码:725 / 728
页数:4
相关论文
共 50 条
  • [41] Spontaneous preterm birth and cervical length in a pregnant Asian population
    Thain, S.
    Yeo, S. H.
    Kwek, K.
    Chern, B.
    Tan, K. H.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2017, 124 : 26 - 27
  • [42] Spontaneous preterm birth and cervical length in a pregnant Asian population
    Thain, Serene
    Yee, George S. H.
    Kwek, Kenneth
    Chern, Bernard
    Tan, Kok Hian
    PLOS ONE, 2020, 15 (04):
  • [43] Cochlear Duct Length Calculation: Comparison Between Using Otoplan and Curved Multiplanar Reconstruction in Nonmalformed Cochlea
    Chen, Ying
    Chen, Jianqing
    Tan, Haoyue
    Jiang, Mengda
    Wu, Yingwei
    Zhang, Zhihua
    Li, Yun
    Jia, Huan
    Wu, Hao
    OTOLOGY & NEUROTOLOGY, 2021, 42 (07) : E875 - E880
  • [44] CT imaging-based approaches to cochlear duct length estimation—a human temporal bone study
    Tabita Breitsprecher
    Anandhan Dhanasingh
    Marko Schulze
    Markus Kipp
    Rami Abu Dakah
    Tobias Oberhoffner
    Michael Dau
    Bernhard Frerich
    Marc-André Weber
    Soenke Langner
    Robert Mlynski
    Nora M. Weiss
    European Radiology, 2022, 32 : 1014 - 1023
  • [45] Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques
    Taeger, Johannes
    Mueller-Graff, Franz Tassilo
    Ilgen, Lukas
    Schendzielorz, Phillip
    Hagen, Rudolf
    Neun, Tilman
    Rak, Kristen
    OTO OPEN, 2021, 5 (03)
  • [46] Evaluation of Cochlear Duct Length Measurements From a 3D Analytical Cochlear Model Using Synchrotron Radiation Phase-Contrast Imaging
    Helpard, Luke W.
    Rohani, Seyed A.
    Ladak, Hanif M.
    Agrawal, Sumit K.
    OTOLOGY & NEUROTOLOGY, 2020, 41 (01) : E21 - E27
  • [47] CT-scan contouring technique allows for direct and reliable measurements of the cochlear duct length: implication in cochlear implantation with straight electrode-arrays
    Thi Hau Vu
    Perazzini, Chiara
    Puechmaille, Mathilde
    Bachy, Aurelie
    Mulliez, Aurelien
    Boyer, Louis
    Mom, Thierry
    Gabrillargues, Jean
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2019, 276 (08) : 2135 - 2140
  • [48] CT-scan contouring technique allows for direct and reliable measurements of the cochlear duct length: implication in cochlear implantation with straight electrode-arrays
    Thi Hau Vu
    Chiara Perazzini
    Mathilde Puechmaille
    Aurélie Bachy
    Aurélien Mulliez
    Louis Boyer
    Thierry Mom
    Jean Gabrillargues
    European Archives of Oto-Rhino-Laryngology, 2019, 276 : 2135 - 2140
  • [49] CT imaging-based approaches to cochlear duct length estimation-a human temporal bone study
    Breitsprecher, Tabita
    Dhanasingh, Anandhan
    Schulze, Marko
    Kipp, Markus
    Dakah, Rami Abu
    Oberhoffner, Tobias
    Dau, Michael
    Frerich, Bernhard
    Weber, Marc-Andre
    Langner, Soenke
    Mlynski, Robert
    Weiss, Nora M.
    EUROPEAN RADIOLOGY, 2022, 32 (02) : 1014 - 1023
  • [50] A RAPID METHOD FOR MEASURING THE LENGTH OF A POPULATION OF MESSENGER RIBONUCLEIC-ACID
    MOALIC, JM
    BERCOVICI, J
    SWYNGHEDAUW, B
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1983, 76 (09): : 1098 - 1098