Measuring cochlear duct length in Asian population: worth giving a thought!

被引:29
|
作者
Grover, Mohnish [1 ]
Sharma, Shitanshu [1 ]
Singh, Shashank Nath [1 ]
Kataria, Tanmaya [1 ]
Lakhawat, Rajendra Singh [1 ]
Sharma, Man Prakash [1 ]
机构
[1] SMS Med Coll & Hosp, Dept Otorhinolaryngol & Head Neck Surg, Jaipur 302004, Rajasthan, India
关键词
Cochlear duct length; Cochlear implantation;
D O I
10.1007/s00405-018-4868-9
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
The anatomy of the cochlea forms the basis for a successful cochlear implantation. Cochlear duct length (CDL) is defined as the length of the scala media as measured from the middle of the round window to helicotrema. Preoperative measurement of CDL is particularly important when precise intracochlear electrode array placement is desired. It can be done both histologically and radiologically. Preoperative high-resolution computed tomography (HRCT) scan which forms an integral part of cochlear implant workup is a useful tool to calculate CDL using 3D reconstructions. This study was done in SMS Medical College and Hospital, Jaipur, India, which is a tertiary care hospital and referral centre for cochlear implants. HRCT temporal bones of all children less than 6 years of age, with congenital bilateral severe-to-profound SNHL who were being worked up for cochlear implant were studied and analysed. 124 patients (56 females and 68 males) with hearing loss were evaluated for cochlear implantation. HRCT temporal bone of these patients was analysed and a variable A was measured which is defined as the linear measurement from the round window to the farthest point on the opposite wall of the cochlea on a reformatted CT scan slice. Mean of distance A for right ear of these patients was 8.10 mm (range 7.7-9.2 mm). Mean for the same in left ear of these patients was 8.14 mm (range 7.7-9.0 mm), giving an overall average of 8.12 mm. Using the formula, CDL = 4.16A-3.98, we calculated the length of cochlear duct. Mean cochlear duct length was 29.8 mm with a range from 28 to 34.3 mm. To the best of our knowledge, this is the first large sample study of cochlear length in population of this part of the world. A smaller cochlear length in this part of the world as compared to the Caucasian cochlear duct is a significant finding in understanding of the cochlear anatomy and physiology. It would also have great implications on the insertion depth in cochlear implantation.
引用
收藏
页码:725 / 728
页数:4
相关论文
共 50 条
  • [21] Characterization of the human helicotrema: implications for cochlear duct length and frequency mapping
    Luke Helpard
    Hao Li
    Helge Rask-Andersen
    Hanif M. Ladak
    Sumit K. Agrawal
    Journal of Otolaryngology - Head & Neck Surgery, 49
  • [22] Cochlear duct length in Pakistani cochlear implant recipients gender, age and side association: A Radiological Measure
    Sarwar, Zahra
    Ahmed, Jawwad
    Saqulain, Ghulam
    Khan, Muhammad Iqbal Javed
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2024, 40 (01) : 41 - 45
  • [23] Cochlear duct length and cochlear distance on preoperative CT: imaging markers for estimating insertion depth angle of cochlear implant electrode
    Oh, Jiseon
    Cheon, Jung-Eun
    Park, Junghoan
    Choi, Young Hun
    Cho, Yeon Jin
    Lee, Seunghyun
    Ha Oh, Seung
    Shin, Su-Mi
    Park, Sun-Won
    EUROPEAN RADIOLOGY, 2021, 31 (03) : 1260 - 1267
  • [24] Cochlear duct length and cochlear distance on preoperative CT: imaging markers for estimating insertion depth angle of cochlear implant electrode
    Jiseon Oh
    Jung-Eun Cheon
    Junghoan Park
    Young Hun Choi
    Yeon Jin Cho
    Seunghyun Lee
    Seung Ha Oh
    Su-Mi Shin
    Sun-Won Park
    European Radiology, 2021, 31 : 1260 - 1267
  • [25] Common Bile Duct Exploration in an Elderly Asian Population
    Shelat, Vishal G.
    Chia, Vincent J. M.
    Low, JeeKeem
    INTERNATIONAL SURGERY, 2015, 100 (02) : 261 - 267
  • [26] Enhancing cochlear duct length estimation by incorporating second-turn parameters
    Alahmadi, Asma
    Abdelsamad, Yassin
    Dhanasingh, Anandhan
    Almuhawas, Fida
    Alsanosi, Abdulrahman
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [27] Accuracy of Preoperative Cochlear Duct Length Estimation and Angular Insertion Depth Prediction
    Breitsprecher, Tabita
    Mlynski, Robert
    Voelter, Christiane
    Van de Heyning, Paul
    Van Rompaey, Vincent
    Dazert, Stefan
    Weiss, Nora M. M.
    OTOLOGY & NEUROTOLOGY, 2023, 44 (08) : E566 - E571
  • [28] Comparison of cochlear duct length between the Saudi and non-Saudi populations
    Alanazi, Alaa
    Alzhrani, Farid
    ANNALS OF SAUDI MEDICINE, 2018, 38 (02) : 125 - 129
  • [29] Enhancing cochlear duct length estimation by incorporating second-turn parameters
    Asma Alahmadi
    Yassin Abdelsamad
    Anandhan Dhanasingh
    Fida Almuhawas
    Abdulrahman Alsanosi
    Scientific Reports, 13
  • [30] An automated A-value measurement tool for accurate cochlear duct length estimation
    Iyaniwura, John E.
    Elfarnawany, Mai
    Ladak, Hanif M.
    Agrawal, Sumit K.
    JOURNAL OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2018, 47