Influence of the validation method on diagnostic accuracy for caries. A comparison of six digital and two conventional radiographic systems

被引:45
|
作者
Hintze, H [1 ]
Wenzel, A [1 ]
机构
[1] Aarhus Univ, Royal Dent Coll, Dept Oral Radiol, Fac Hlth Sci, DK-8000 Aarhus C, Denmark
关键词
digital radiography; dental; dental caries; diagnostic test; ROC curve;
D O I
10.1038/sj.dmfr.4600645
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate the influence of the validation method on the diagnostic accuracy and the relative comparison of eight radiographic systems for caries detection. Methods: Three hundred and thirty-eight approximal and 145 occlusal surfaces were radiographed under standardised conditions using six CCD-based sensor systems: MPDx (Dental/Medical Diagnostic Systems Inc., Woodland Hills, CA, USA), Dixi (Planmeca, Helsinki, Finland), Sidexis (Sirona, Bensheim, Germany), RVG(old) (Trophy, Paris, France, 1994 model), RVG(new) (Trophy, Paris, France, 2000 model) and Visualix (Gendex, Milan, Italy) and two film systems: Ektaspeed Plus and Insight (Eastman Kodak, Rochester, NY, USA). Four observers examined the radiographs for approximal and occlusal caries using a five-point confidence scale. The presence of caries was validated histologically and radiographically. Diagnostic accuracy was evaluated using ROC curve areas (A(z)). Results: For both approximal and occlusal caries the mean A(z) of the eight radiographic systems was significantly higher using radiographic than histological validation (P<0.001). Using histological validation for approximal caries, Dixi (A(z)=0.71) and Ektaspeed Plus (A(z)=0.7) were not significantly different, but Dixi was significantly more accurate than the other digital systems and the Insight film. Using radiographic validation for approximal caries, Ektaspeed Plus (A(z)=0.87) was significantly more accurate than Dixi (A(z)=0.82). Dixi was significantly more accurate than MPDx (A(z) = 0.74), RVG(old) (A(z) = 0.77), RVG(new) (A(z) = 0.77) and Visualix (A(z)= 0.76). Corresponding variations were found for occlusal caries depending on the validation method. Using histological validation, MPDx (A(z)=0.76) was significantly less accurate than Dixi (A(z)=0.81), Sidexis (A(z)=0.8), Ektaspeed Plus (A(z)=0.82) and Insight (A(z)=0.81). Using radiographic validation, MPDx (A(z)=0.83) was also significantly less accurate than RVG(old) (A(z)= 0.89) and RVG(new) (A(z) = 0.9). Conclusion: A(z) obtained from radiographic validation was significantly higher than A(z) obtained from histological validation. Comparison of the diagnostic efficacy for caries of the eight radiographic systems was strongly influenced by the validation method.
引用
收藏
页码:44 / 49
页数:6
相关论文
共 46 条
  • [1] Influence of the validation method on caries diagnostic accuracy of radiographic systems.
    Hintze, H
    Wenzel, A
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B355 - B355
  • [2] Diagnostic quality of conventional and digital radiographic images of dental caries.
    Tosoni, GM
    Capelozza, ALA
    Loffredo, LCM
    Tavano, O
    Scaf, G
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1142 - 1142
  • [3] Influence of materials radiopacity in the radiographic diagnosis of secondary caries: evaluation in film and two digital systems
    Pedrosa, R. F.
    Brasileiro, I. V.
    dos Anjos Pontual, M. L.
    dos Anjos Pontual, A.
    da Silveira, M. M. F.
    DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (06) : 344 - 350
  • [4] Laser fluorescence method:: comparison between two tables used for detection of occlusal caries.
    Mendonça, SMS
    Ferreira, EF
    Paixao, HH
    Mesquita, N
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B140 - B140
  • [5] Comparison of six digital radiographic systems for endodontic length determination.
    AbdelNabi, HM
    Vandre, R
    Farman, AG
    Pajak, J
    Scarfe, WC
    Farman, TT
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 1011 - 1011
  • [6] Radiographic detection of approximal caries: a comparison of dental films and digital imaging systems
    Syriopoulos, K
    Sanderink, GCH
    Velders, XL
    van der Stelt, PF
    DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (05) : 312 - 318
  • [7] IMAGE QUALITY, DIAGNOSTIC CERTAINTY, AND ACCURACY - COMPARISON OF CONVENTIONAL AND DIGITAL UROGRAMS
    FAJARDO, LL
    HILLMAN, BJ
    UROLOGIC RADIOLOGY, 1988, 10 (02) : 72 - 74
  • [8] Subjective image quality comparison between two digital dental radiographic systems and conventional dental film
    Ajmal, Muhammed
    Elshinawy, Mohamed I.
    SAUDI DENTAL JOURNAL, 2014, 26 (04) : 145 - 150
  • [9] Diagnostic Accuracy of Digital and Conventional Radiography in the Detection of Non-Cavitated Approximal Dental Caries
    Abesi, Farida
    Mirshekar, Alireza
    Moudi, Ehsan
    Seyedmajidi, Maryam
    Haghanifar, Sina
    Haghighat, Nima
    Bijani, Ali
    IRANIAN JOURNAL OF RADIOLOGY, 2012, 9 (01) : 17 - 21
  • [10] Diagnostic accuracy of two software modalities for detection of caries lesions in digital radiographs from four dental systems
    Hintze, H
    DENTOMAXILLOFACIAL RADIOLOGY, 2006, 35 (02) : 78 - 82