Amplatzer left atrial appendage closure: Single versus combined procedures

被引:5
|
作者
Kleinecke, Caroline [1 ,5 ]
Buffle, Eric [2 ]
Link, Juergen [3 ]
Haener, Jonas [2 ]
Sedaghat, Alexander [4 ]
Galea, Roberto [2 ]
Streit, Samuel R. [2 ]
Windecker, Stephan [2 ]
Meier, Bernhard [2 ]
Gloekler, Steffen [2 ,5 ]
机构
[1] Klinikum Lichtenfels, Cardiol, Lichtenfels, Germany
[2] Univ Hosp Bern, Cardiovasc Dept, Cardiol, Bern, Switzerland
[3] Dreifaltigkeits Hosp, Dept Anesthesiol, Wesseling, Germany
[4] Univ Klinikum Bonn, Herzzentrum Bonn, Bonn, Germany
[5] Klinikum Hochrhein, Cardiol, Kaiserstr 100, D-79761 Waldshut Tiengen, Germany
关键词
Amplatzer; atrial fibrillation; combined; left atrial appendage closure; stroke; EXPERT CONSENSUS STATEMENT; END-POINT DEFINITIONS; OCCLUSION; FIBRILLATION; FEASIBILITY; MULTICENTER; SAFETY; STROKE;
D O I
10.1002/ccd.29271
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study compares procedural and late clinical outcomes of left atrial appendage closure (LAAC) with Amplatzer devices as a single versus a combined procedure with other structural or coronary interventions. Background Multiple cardiac conditions are frequent among elderly patients and invite simultaneous treatment to ensure a favorable patient outcomes. Methods 559 consecutive patients (73.3 +/- 11.1 years) underwent LAAC with Amplatzer devices at two centres (Bern and Zurich university hospitals, Switzerland) either as a single procedure or combined with other interventions. The primary safety endpoint was a composite of major peri-procedural complications and major bleeding at follow-up, the primary efficacy endpoint included stroke, systemic embolism, and cardiovascular/unexplained death. All event rates are reported per 100 patient-years. Results In 263 single and 296 combined procedures with percutaneous coronary interventions (47.6%), closure of an atrial septal defect (8.4%) or a patent foramen ovale (36.5%), transcatheter aortic valve implantation (10.1%), mitral clipping (4.1%), atrial fibrillation ablation (8.8%), or another procedure (3.0%) were analyzed. Device success (96.6% [single] vs. 99.0% [combined],p= .08) did not differ between the groups. After a mean follow-up of 2.6 +/- 1.5 vs. 2.5 +/- 1.5 years and a total of 1,422 patient-years, the primary efficacy (40/677, 5.9% [single] vs. 37/745, 5.0% [combined]; HR, 1.2, 95% CI, 0.8-1.9,p= .44), as well as the primary safety endpoint (25/677, 3.7% vs 28/745, 3.8%; HR, 1.0, 95% CI, 0.6-1.8,p= .89) were comparable. Conclusions LAAC with Amplatzer devices combined with structural, coronary, and electrophysiological procedures offers procedural feasibility and safety, as well as long-term efficacy.
引用
收藏
页码:E973 / E981
页数:9
相关论文
共 50 条
  • [1] Late clinical outcomes of lambre versus amplatzer occluders for left atrial appendage closure
    Schnupp, Steffen
    Liu, Xiao-Xia
    Buffle, Eric
    Gloekler, Steffen
    Mohrez, Yamen
    Cheikh-Ibrahim, Mohammad
    Allakkis, Wasim
    Brachmann, Johannes
    Park, Jai-Wun
    Kleinecke, Caroline
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (04) : 934 - 942
  • [2] LEFT ATRIAL APPENDAGE PERIDEVICE LEAK CLOSURE WITH AMPLATZER PLUG
    Qasim, Muhammad
    Tariq, Rana
    Bang, Vigyan
    Hornsby, Kyle
    Mattson, Scott
    Zawacki, Kevin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 2505 - 2505
  • [3] Thrombus formation on an Amplatzer closure device after left atrial appendage closure
    Lammers, Jeroen
    Elenbaas, Ted
    Meijer, Albert
    EUROPEAN HEART JOURNAL, 2013, 34 (10) : 741 - 741
  • [4] Left Atrial Appendage Closure with the Amplatzer Cardiac Plug in Patients with Atrial Fibrillation
    Guerios, Enio Eduardo
    Schmid, Michael
    Gloekler, Steffen
    Khattab, Ahmed A.
    Wenaweser, Peter M.
    Windecker, Stephan
    Meier, Bernhard
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2012, 98 (06) : 528 - 536
  • [5] Transseptal Puncture Through Amplatzer Atrial Septal Occluder for Left Atrial Appendage Closure
    Gloekler, Steffen
    Shakir, Samera
    Meier, Bernhard
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (21) : 2222 - 2223
  • [6] Early results of first versus second generation Amplatzer occluders for left atrial appendage closure in patients with atrial fibrillation
    Gloekler, Steffen
    Shakir, Samera
    Doblies, Janosch
    Khattab, Ahmed A.
    Praz, Fabien
    Guerios, Enio
    Koermendy, Dezsoe
    Stortecky, Stefan
    Pilgrim, Thomas
    Buellesfeld, Lutz
    Wenaweser, Peter
    Windecker, Stephan
    Moschovitis, Aris
    Jaguszewski, Milosz
    Landmesser, Ulf
    Nietlispach, Fabian
    Meier, Bernhard
    CLINICAL RESEARCH IN CARDIOLOGY, 2015, 104 (08) : 656 - 665
  • [7] Early results of first versus second generation Amplatzer occluders for left atrial appendage closure in patients with atrial fibrillation
    Steffen Gloekler
    Samera Shakir
    Janosch Doblies
    Ahmed A. Khattab
    Fabien Praz
    Ênio Guerios
    Dezsoe Koermendy
    Stefan Stortecky
    Thomas Pilgrim
    Lutz Buellesfeld
    Peter Wenaweser
    Stephan Windecker
    Aris Moschovitis
    Milosz Jaguszewski
    Ulf Landmesser
    Fabian Nietlispach
    Bernhard Meier
    Clinical Research in Cardiology, 2015, 104 : 656 - 665
  • [8] Percutaneous Closure of a Very Large Left Atrial Appendage Using the Amplatzer Amulet
    Freixa, Xavier
    Chan, Jason Leung Kwai
    Tzikas, Apostolos
    Garceau, Patrick
    Basmadjian, Arsene
    Ibrahim, Reda
    CANADIAN JOURNAL OF CARDIOLOGY, 2013, 29 (10) : 1329.e9 - 1329.e11
  • [9] Left Atrial Appendage Closure With Amplatzer Cardiac Plug in Atrial Fibrillation: Initial European Experience
    Park, Jai-Wun
    Bethencourt, Armando
    Sievert, Horst
    Santoro, Gennaro
    Meier, Bernhard
    Walsh, Kevin
    Ramon Lopez-Minquez, Jose
    Meerkin, David
    Valdes, Mariano
    Ormerod, Oliver
    Leithaeuser, Boris
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 77 (05) : 700 - 706
  • [10] Single antiplatelet therapy following Amplatzer left atrial appendage occlusion
    Kramer, Anders
    Korsholm, Kasper
    Nielsen-Kudsk, Jens Erik
    EUROINTERVENTION, 2024, 20 (05) : e301 - e311