Late clinical outcomes of lambre versus amplatzer occluders for left atrial appendage closure

被引:16
|
作者
Schnupp, Steffen [1 ]
Liu, Xiao-Xia [2 ,3 ]
Buffle, Eric [4 ]
Gloekler, Steffen [4 ,5 ]
Mohrez, Yamen [1 ]
Cheikh-Ibrahim, Mohammad [1 ]
Allakkis, Wasim [1 ]
Brachmann, Johannes [1 ]
Park, Jai-Wun [6 ]
Kleinecke, Caroline [7 ]
机构
[1] Klinikum Coburg, Dept Cardiol, Coburg, Germany
[2] Harbin Med Univ, Dept Cardiol, Hosp 4, Harbin, Peoples R China
[3] Capital Med Univ, Anzhen Hosp, Dept Cardiol, Beijing, Peoples R China
[4] Univ Hosp Bern, Dept Cardiol, Bern, Switzerland
[5] Schwarzwald Baar Klinikum, Dept Cardiol, Villingen Schwenningen, Germany
[6] Charite Berlin Univ Med, Dept Cardiol, Campus Benjamin Franklin, Berlin, Germany
[7] Klinikum Lichtenfels, Dept Cardiol, Prof Arneth Str 2b, D-96215 Lichtenfels, Germany
关键词
Amplatzer; atrial fibrillation; LAmbre; left atrial appendage closure; stroke prevention; END-POINT DEFINITIONS; STROKE PREVENTION; FIBRILLATION; DEVICE; OCCLUSION; MULTICENTER;
D O I
10.1111/jce.14398
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction The LAmbre (LifeTech Scientific, Shenzhen, China) is a novel occluder for left atrial appendage closure (LAAC) in patients with atrial fibrillation. This study compares late clinical outcomes of LAmbre and the established Amplatzer devices (Abbott, St Paul, MN). Methods Between 2012 and 2018, 265 consecutive patients underwent LAAC with LAmbre and Amplatzer devices at a single center. After a 3:1 propensity score matching, 40 (LAmbre) vs 107 (Amplatzer) patients were compared by the primary efficacy endpoint of all-cause stroke, systemic embolism and cardiovascular/unexplained death, the primary safety endpoint of major periprocedural complications and major bleeding events at follow-up, and the combined hazard endpoint, a composite of all the above-mentioned hazards. Results The mean age 75.6 +/- 8.9 (LAmbre) vs 75.5 +/- 9.0 (Amplatzer) years, CHA(2)DS(2)-VASc score 4.8 +/- 1.7 vs 4.8 +/- 1.7 and HAS-BLED score 3.1 +/- 0.9 vs 3.2 +/- 0.8 were similar. After 3.6 +/- 1.9 vs 2.5 +/- 1.4 years, the clinical efficacy (12/146, 8.2% [LAmbre] vs 28/266, 10.5% [Amplatzer]; hazard ratio [HR], 0.73; 95% confidence interval [CI], 0.38-1.40; P = .34) and safety (5/146, 3.4% vs 14/266, 5.3%; HR, 0.47; 95% CI, 0.14-1.6; P = .22), as well as the combined hazard endpoint (15/146, 10.3% vs 36/266, 13.6%; HR, 0.67; 95% CI, 0.36-1.25; P = .21) were comparable. Conclusion In the presented report, in patients with nonvalvular atrial fibrillation, the LAmbre offered similar long-term efficacy and safety in comparison to Amplatzer devices.
引用
收藏
页码:934 / 942
页数:9
相关论文
共 50 条
  • [1] Long-term clinical outcomes of Amplatzer cardiac plug versus Amulet occluders for left atrial appendage closure
    Kleinecke, Caroline
    Cheikh-Ibrahim, Mohammad
    Schnupp, Steffen
    Fankhauser, Mate
    Nietlispach, Fabian
    Park, Jai-Wun
    Brachmann, Johannes
    Windecker, Stephan
    Meier, Bernhard
    Gloekler, Steffen
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 96 (03) : E324 - E331
  • [2] Clinical outcomes of Watchman vs. Amplatzer occluders for left atrial appendage closure (WATCH at LAAC)
    Kleinecke, Caroline
    Yu, Jiangtao
    Neef, Philip
    Buffle, Eric
    de Marchi, Stefano
    Fuerholz, Monika
    Nietlispach, Fabian
    Valgimigli, Marco
    Streit, Samuel R.
    Fankhauser, Mate
    Duenninger, Erich
    Windecker, Stephan
    Meier, Bernhard
    Gloekler, Steffen
    EUROPACE, 2020, 22 (06): : 916 - 923
  • [3] Early results of first versus second generation Amplatzer occluders for left atrial appendage closure in patients with atrial fibrillation
    Gloekler, Steffen
    Shakir, Samera
    Doblies, Janosch
    Khattab, Ahmed A.
    Praz, Fabien
    Guerios, Enio
    Koermendy, Dezsoe
    Stortecky, Stefan
    Pilgrim, Thomas
    Buellesfeld, Lutz
    Wenaweser, Peter
    Windecker, Stephan
    Moschovitis, Aris
    Jaguszewski, Milosz
    Landmesser, Ulf
    Nietlispach, Fabian
    Meier, Bernhard
    CLINICAL RESEARCH IN CARDIOLOGY, 2015, 104 (08) : 656 - 665
  • [4] Early results of first versus second generation Amplatzer occluders for left atrial appendage closure in patients with atrial fibrillation
    Steffen Gloekler
    Samera Shakir
    Janosch Doblies
    Ahmed A. Khattab
    Fabien Praz
    Ênio Guerios
    Dezsoe Koermendy
    Stefan Stortecky
    Thomas Pilgrim
    Lutz Buellesfeld
    Peter Wenaweser
    Stephan Windecker
    Aris Moschovitis
    Milosz Jaguszewski
    Ulf Landmesser
    Fabian Nietlispach
    Bernhard Meier
    Clinical Research in Cardiology, 2015, 104 : 656 - 665
  • [5] Amplatzer left atrial appendage closure: Single versus combined procedures
    Kleinecke, Caroline
    Buffle, Eric
    Link, Juergen
    Haener, Jonas
    Sedaghat, Alexander
    Galea, Roberto
    Streit, Samuel R.
    Windecker, Stephan
    Meier, Bernhard
    Gloekler, Steffen
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 97 (07) : E973 - E981
  • [6] Percutaneous left atrial appendage closure using the LAmbre device in patients with atrial fibrillation and left atrial appendage thrombus
    Jin, Lu-Shen
    Ke, Jin-Yan
    Lin, Yuan-Nan
    Li, Ling
    Fu, Jia-Yang
    Chen, Yi-Lian
    Qiu, Yi-Xuan
    Li, Xiao-Wei
    Pan, Yang-Qi
    Li, Yue-Chun
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [7] Impact of left atrial appendage orifice diameter on the safety and efficacy of left atrial appendage closure using the LAmbre device
    Zhuo, Weidong
    Wang, Binhao
    Fu, Guohua
    Yu, Yibo
    Feng, Mingjun
    Liu, Jing
    Du, Xianfeng
    Chu, Huimin
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2024, 123 (05) : 600 - 605
  • [8] Personalized occluders for the left atrial appendage
    Gianni, Carola
    Natale, Andrea
    NATURE BIOMEDICAL ENGINEERING, 2018, 2 (01): : 2 - 3
  • [9] LEFT ATRIAL APPENDAGE PERIDEVICE LEAK CLOSURE WITH AMPLATZER PLUG
    Qasim, Muhammad
    Tariq, Rana
    Bang, Vigyan
    Hornsby, Kyle
    Mattson, Scott
    Zawacki, Kevin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 2505 - 2505
  • [10] Personalized occluders for the left atrial appendage
    Carola Gianni
    Andrea Natale
    Nature Biomedical Engineering, 2018, 2 : 2 - 3