Amplatzer left atrial appendage closure: Single versus combined procedures

被引:5
|
作者
Kleinecke, Caroline [1 ,5 ]
Buffle, Eric [2 ]
Link, Juergen [3 ]
Haener, Jonas [2 ]
Sedaghat, Alexander [4 ]
Galea, Roberto [2 ]
Streit, Samuel R. [2 ]
Windecker, Stephan [2 ]
Meier, Bernhard [2 ]
Gloekler, Steffen [2 ,5 ]
机构
[1] Klinikum Lichtenfels, Cardiol, Lichtenfels, Germany
[2] Univ Hosp Bern, Cardiovasc Dept, Cardiol, Bern, Switzerland
[3] Dreifaltigkeits Hosp, Dept Anesthesiol, Wesseling, Germany
[4] Univ Klinikum Bonn, Herzzentrum Bonn, Bonn, Germany
[5] Klinikum Hochrhein, Cardiol, Kaiserstr 100, D-79761 Waldshut Tiengen, Germany
关键词
Amplatzer; atrial fibrillation; combined; left atrial appendage closure; stroke; EXPERT CONSENSUS STATEMENT; END-POINT DEFINITIONS; OCCLUSION; FIBRILLATION; FEASIBILITY; MULTICENTER; SAFETY; STROKE;
D O I
10.1002/ccd.29271
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study compares procedural and late clinical outcomes of left atrial appendage closure (LAAC) with Amplatzer devices as a single versus a combined procedure with other structural or coronary interventions. Background Multiple cardiac conditions are frequent among elderly patients and invite simultaneous treatment to ensure a favorable patient outcomes. Methods 559 consecutive patients (73.3 +/- 11.1 years) underwent LAAC with Amplatzer devices at two centres (Bern and Zurich university hospitals, Switzerland) either as a single procedure or combined with other interventions. The primary safety endpoint was a composite of major peri-procedural complications and major bleeding at follow-up, the primary efficacy endpoint included stroke, systemic embolism, and cardiovascular/unexplained death. All event rates are reported per 100 patient-years. Results In 263 single and 296 combined procedures with percutaneous coronary interventions (47.6%), closure of an atrial septal defect (8.4%) or a patent foramen ovale (36.5%), transcatheter aortic valve implantation (10.1%), mitral clipping (4.1%), atrial fibrillation ablation (8.8%), or another procedure (3.0%) were analyzed. Device success (96.6% [single] vs. 99.0% [combined],p= .08) did not differ between the groups. After a mean follow-up of 2.6 +/- 1.5 vs. 2.5 +/- 1.5 years and a total of 1,422 patient-years, the primary efficacy (40/677, 5.9% [single] vs. 37/745, 5.0% [combined]; HR, 1.2, 95% CI, 0.8-1.9,p= .44), as well as the primary safety endpoint (25/677, 3.7% vs 28/745, 3.8%; HR, 1.0, 95% CI, 0.6-1.8,p= .89) were comparable. Conclusions LAAC with Amplatzer devices combined with structural, coronary, and electrophysiological procedures offers procedural feasibility and safety, as well as long-term efficacy.
引用
收藏
页码:E973 / E981
页数:9
相关论文
共 50 条
  • [21] Long-term clinical outcomes of Amplatzer cardiac plug versus Amulet occluders for left atrial appendage closure
    Kleinecke, Caroline
    Cheikh-Ibrahim, Mohammad
    Schnupp, Steffen
    Fankhauser, Mate
    Nietlispach, Fabian
    Park, Jai-Wun
    Brachmann, Johannes
    Windecker, Stephan
    Meier, Bernhard
    Gloekler, Steffen
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 96 (03) : E324 - E331
  • [22] Amplatzer amulet versus watchman device for percutaneous left atrial appendage closure: A systematic review and meta-analysis
    Jaiswal, Vikash
    Ang, Song Peng
    Shrestha, Abhigan Babu
    Wajid, Zarghoona
    Endurance, Evbayekha Osas
    Ayoobkhan, Fathima Shehnaz
    Khan, Shazia
    Garimellla, Vamsi
    Huang, Helen
    Ghanim, Mohammed
    Song, David
    Sharma, Prachi
    Alraies, M. Chadi
    Biswas, Monodeep
    MEDICINE, 2023, 102 (26) : E34185
  • [23] Amplatzer amulet versus watchman device for percutaneous left atrial appendage closure: a systematic review and meta-analysis
    Jaiswal, Vikash
    Ang, Song P.
    Shrestha, A. B.
    Sharma, Prachi
    Endurance, E. O.
    Khan, Shazia
    Mukherjee, D.
    Jaiswal, Akash
    Chia, Jia E. E.
    Huang, Helen
    Alraies, M. C.
    Biswas, M.
    EUROPEAN HEART JOURNAL, 2023, 44 : 19 - 20
  • [24] Durable Single Shot Cryoballoon Isolation of the Left Atrial Appendage Followed by Percutaneous Left Atrial Appendage Closure
    Bordignon, Stefano
    Perrotta, Laura
    Fuernkranz, Alexander
    Bologna, Fabrizio
    Schmidt, Boris
    Chun, K. R. Julian
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2015, 8 (03): : 751 - 752
  • [25] PERCUTANEOUS LEFT ATRIAL APPENDAGE CLOSURE IN PATIENTS WITH LEFT ATRIAL APPENDAGE THROMBUS
    Meincke, Felix
    Kreidel, Felix
    Kuck, Karl-Heinz
    Bergmann, Martin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A345 - A345
  • [26] Percutaneous left atrial appendage closure in a surgically ligated left atrial appendage
    Wong, Ivan
    Vejlstrup, Niels Grove
    Bieliauskas, Gintautas
    Sondergaard, Lars
    De Backer, Ole
    EUROINTERVENTION, 2022, 18 (02) : E183 - E184
  • [27] Percutaneous left atrial appendage closure in patients with left atrial appendage thrombus
    Meincke, Felix
    Kreidel, Felix
    von Wedel, Jasper
    Schaefer, Ulrich
    Kuck, Karl-Heinz
    Bergmann, Martin W.
    EuroIntervention, 2015, 10 (10) : 1208 - 1208
  • [28] Prolapse of left atrial appendage during transcatheter left atrial appendage closure
    Pandey, Amitabh C.
    Alhama-Belotto, Marta
    Niekerk, Christoffel J. van
    Gibson, Douglas N.
    EUROPEAN HEART JOURNAL, 2019, 40 (35) : 2998 - 2998
  • [29] Left Atrial Appendage Closure in Atrial Fibrillation
    Fauchier, Laurent
    Cinaud, Alexandre
    Brigadeau, Francois
    Lepillier, Antoine
    Pierre, Bertrand
    Gras, Daniel
    Mansourati, Jacques
    Deharo, Jean Claude
    Montalescot, Gilles
    Defaye, Pascal
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (22) : 2806 - 2807
  • [30] First-in-Human Experience With the Amplatzer Steerable Delivery Sheath for Left Atrial Appendage Closure
    Saw, Jacqueline
    Perrin, Nils
    Nestelberger, Thomas
    Mondesert, Blandine
    Tsang, Michael
    Ibrahim, Reda
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (19) : 2191 - 2193