The Impact of Integration of a Multidetector Computed Tomography Annulus Area Sizing Algorithm on Outcomes of Transcatheter Aortic Valve Replacement A Prospective, Multicenter, Controlled Trial

被引:261
|
作者
Binder, Ronald K. [1 ]
Webb, John G. [1 ]
Willson, Alexander B. [1 ]
Urena, Marina [2 ]
Hansson, Nicolaj C. [3 ]
Norgaard, Bjarne L. [3 ]
Pibarot, Philippe [2 ]
Barbanti, Marco [1 ]
Larose, Eric [2 ]
Freeman, Melanie [1 ]
Dumont, Eric [2 ]
Thompson, Chris [1 ]
Wheeler, Miriam [1 ]
Moss, Robert R. [1 ]
Yang, Tae-hyun [1 ]
Pasian, Sergio [2 ]
Hague, Cameron J. [1 ]
Giang Nguyen [1 ]
Raju, Rekha [1 ]
Toggweiler, Stefan [1 ]
Min, James K. [4 ]
Wood, David A. [5 ]
Rodes-Cabau, Josep [2 ]
Leipsic, Jonathon [1 ]
机构
[1] Univ British Columbia, St Pauls Hosp, Vancouver, BC V5Z 1M9, Canada
[2] Univ Laval, Quebec Heart & Lung Inst, Quebec City, PQ, Canada
[3] Aarhus Univ, Hosp Skejby, Aarhus, Denmark
[4] Cedars Sinai Heart Inst, Los Angeles, CA USA
[5] Univ British Columbia, Vancouver Gen Hosp, Vancouver, BC V5Z 1M9, Canada
关键词
annulus area; multidetector computed tomography; transcatheter aortic valve replacement; transcatheter heart valve sizing; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; HEART-VALVE; IMPLANTATION; REGURGITATION;
D O I
10.1016/j.jacc.2013.04.036
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study prospectively investigated the impact of integration of a multidetector computed tomography (MDCT) annular area sizing algorithm on transcatheter aortic valve replacement (TAVR) outcomes. Background Appreciation of the 3-dimensional, noncircular geometry of the aortic annulus is important for transcatheter heart valve (THV) sizing. Methods Patients being evaluated for TAVR in 4 centers underwent pre-procedural MDCT. Recommendations for balloon-expandable THV size selection were based on an MDCT sizing algorithm with an optimal goal of modest annulus area oversizing (5% to 10%). Consecutive patients who underwent TAVR with the algorithm (MDCT group) were compared with consecutive patients without the algorithm (control group). The primary endpoint was the incidence of more than mild paravalvular regurgitation (PAR), and the secondary endpoint was the composite of in-hospital death, aortic annulus rupture, and severe PAR. Results Of 266 patients, 133 consecutive patients underwent TAVR (SAPIEN XT THV) in the MDCT group and 133 consecutive patients were in the control group. More than mild PAR was present in 5.3% (7 of 133) of the MDCT group and in 12.8% (17 of 133) in the control group (p = 0.032). The combined secondary endpoint occurred in 3.8% (5 of 133) of the MDCT group and in 11.3% (15 of 133) of the control group (p = 0.02), driven by the difference of severe PAR. Conclusions The implementation of an MDCT annulus area sizing algorithm for TAVR reduces PAR. Three-dimensional aortic annular assessment and annular area sizing should be considered for TAVR. (C) 2013 by the American College of Cardiology Foundation
引用
收藏
页码:431 / 438
页数:8
相关论文
共 50 条
  • [41] Computed tomography-based sizing recommendations for transcatheter aortic valve replacement with balloon-expandable valves: Comparison with transesophageal echocardiography and rationale for implementation in a prospective trial
    Willson, Alexander B.
    Webb, John G.
    Freeman, Melanie
    Wood, David A.
    Gurvitch, Ronen
    Thompson, Christopher R.
    Moss, Robert R.
    Toggweiler, Stefan
    Binder, Ronnie K.
    Munt, Bradley
    Cheung, Anson
    Hague, Cameron
    Ye, Jian
    Leipsic, Jonathon A.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (06) : 406 - 414
  • [42] Bicuspid aortic valve sizing for transcatheter aortic valve implantation: Development and validation of an algorithm based on multi-slice computed tomography
    Petronio, Anna S.
    Angelillis, Marco
    De Backer, Ole
    Giannini, Cristina
    Costa, Giulia
    Fiorina, Claudia
    Castriota, Fausto
    Bedogni, Francesco
    Laborde, Jean C.
    Sondergaard, Lars
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2020, 14 (05) : 452 - 461
  • [43] Potential impact of dynamic automated CT aortic annular measurements on outcomes for transcatheter aortic valve replacement sizing
    Subramanyam, Pritha
    Legasto, Alan C.
    Al'Aref, Subhi J.
    Wong, Shing Chiu
    Truong, Quynh A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (11): : 2291 - 2297
  • [44] Multidetector Computed Tomography (MDCT) Angiography in the Pre-Procedural Assessment of Patients Undergoing Transcatheter Aortic Valve Replacement
    Duran, Cihan
    Masood, Irfan
    Duran, Alper
    Frank, Luba
    Saleem, Arsalan
    Muthupillai, Raja
    Cheong, Benjamin Y. C.
    EURASIAN JOURNAL OF MEDICINE, 2020, 52 (01): : 86 - 93
  • [45] Diagnostic accuracy of multidetector computed tomography coronary angiography in 325 consecutive patients referred for transcatheter aortic valve replacement
    Andreini, Daniele
    Pontone, Gianluca
    Mushtaq, Saima
    Bartorelli, Antonio L.
    Ballerini, Giovanni
    Bertella, Erika
    Segurini, Chiara
    Conte, Edoardo
    Annoni, Andrea
    Baggiano, Andrea
    Formenti, Alberto
    Fusini, Laura
    Tamborini, Gloria
    Alamanni, Francesco
    Fiorentini, Cesare
    Pepi, Mauro
    AMERICAN HEART JOURNAL, 2014, 168 (03) : 332 - 339
  • [46] 3D echocardiographic analysis of aortic annulus for transcatheter aortic valve replacement using novel aortic valve quantification software: Comparison with computed tomography
    Mediratta, Anuj
    Addetia, Karima
    Medvedofsky, Diego
    Schneider, Robert J.
    Kruse, Eric
    Shah, Atman P.
    Nathan, Sandeep
    Paul, Jonathan D.
    Blair, John E.
    Ota, Takeyoshi
    Balkhy, Husam H.
    Patel, Amit R.
    Mor-Avi, Victor
    Lang, Roberto M.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2017, 34 (05): : 690 - 699
  • [47] Structural Integrity of Balloon-Expandable Stents After Transcatheter Aortic Valve Replacement Assessment by Multidetector Computed Tomography
    Willson, Alexander B.
    Webb, John G.
    Gurvitch, Ronen
    Wood, David A.
    Toggweiler, Stefan
    Binder, Ronald
    Freeman, Melanie
    Madden, Mark
    Hague, Cameron
    Leipsic, Jonathon
    JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (05) : 525 - 532
  • [48] Everything is better in 3D: why transcatheter aortic valve replacement should be guided by multidetector computed tomography
    Hague, Cameron John
    Leipsic, Jonathon
    FUTURE CARDIOLOGY, 2012, 8 (04) : 485 - 487
  • [49] Intra- and Inter-Observer Reproducibility of Transcatheter Aortic Valve Replacement Planning Measurements by Multidetector Computed Tomography
    Heo, Ran
    Hartaigh, Briain O.
    Cho, Iksung
    Valenti, Valentina
    Leipsic, Jonathon
    Wong, S. Chiu
    Salemi, Arash
    Minutello, Robert M.
    Bergman, Geoffrey
    Mini, James K.
    JOURNAL OF HEART VALVE DISEASE, 2015, 24 (05): : 560 - 569
  • [50] The impact of computed tomography-derived aortic atheroma volume on prognosis after transcatheter aortic valve replacement
    Fujita, Hiroshi
    Toba, Takayoshi
    Miwa, Keisuke
    Suzuki, Masataka
    Takahashi, Yu
    Toh, Hiroyuki
    Izawa, Yu
    Kawamori, Hiroyuki
    Otake, Hiromasa
    Fujiwara, Sei
    Watanabe, Yoshiaki
    Kono, Atsushi
    Hirata, Ken-ichi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2021, 344 : 60 - 65