The Impact of Integration of a Multidetector Computed Tomography Annulus Area Sizing Algorithm on Outcomes of Transcatheter Aortic Valve Replacement A Prospective, Multicenter, Controlled Trial

被引:261
|
作者
Binder, Ronald K. [1 ]
Webb, John G. [1 ]
Willson, Alexander B. [1 ]
Urena, Marina [2 ]
Hansson, Nicolaj C. [3 ]
Norgaard, Bjarne L. [3 ]
Pibarot, Philippe [2 ]
Barbanti, Marco [1 ]
Larose, Eric [2 ]
Freeman, Melanie [1 ]
Dumont, Eric [2 ]
Thompson, Chris [1 ]
Wheeler, Miriam [1 ]
Moss, Robert R. [1 ]
Yang, Tae-hyun [1 ]
Pasian, Sergio [2 ]
Hague, Cameron J. [1 ]
Giang Nguyen [1 ]
Raju, Rekha [1 ]
Toggweiler, Stefan [1 ]
Min, James K. [4 ]
Wood, David A. [5 ]
Rodes-Cabau, Josep [2 ]
Leipsic, Jonathon [1 ]
机构
[1] Univ British Columbia, St Pauls Hosp, Vancouver, BC V5Z 1M9, Canada
[2] Univ Laval, Quebec Heart & Lung Inst, Quebec City, PQ, Canada
[3] Aarhus Univ, Hosp Skejby, Aarhus, Denmark
[4] Cedars Sinai Heart Inst, Los Angeles, CA USA
[5] Univ British Columbia, Vancouver Gen Hosp, Vancouver, BC V5Z 1M9, Canada
关键词
annulus area; multidetector computed tomography; transcatheter aortic valve replacement; transcatheter heart valve sizing; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; HEART-VALVE; IMPLANTATION; REGURGITATION;
D O I
10.1016/j.jacc.2013.04.036
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study prospectively investigated the impact of integration of a multidetector computed tomography (MDCT) annular area sizing algorithm on transcatheter aortic valve replacement (TAVR) outcomes. Background Appreciation of the 3-dimensional, noncircular geometry of the aortic annulus is important for transcatheter heart valve (THV) sizing. Methods Patients being evaluated for TAVR in 4 centers underwent pre-procedural MDCT. Recommendations for balloon-expandable THV size selection were based on an MDCT sizing algorithm with an optimal goal of modest annulus area oversizing (5% to 10%). Consecutive patients who underwent TAVR with the algorithm (MDCT group) were compared with consecutive patients without the algorithm (control group). The primary endpoint was the incidence of more than mild paravalvular regurgitation (PAR), and the secondary endpoint was the composite of in-hospital death, aortic annulus rupture, and severe PAR. Results Of 266 patients, 133 consecutive patients underwent TAVR (SAPIEN XT THV) in the MDCT group and 133 consecutive patients were in the control group. More than mild PAR was present in 5.3% (7 of 133) of the MDCT group and in 12.8% (17 of 133) in the control group (p = 0.032). The combined secondary endpoint occurred in 3.8% (5 of 133) of the MDCT group and in 11.3% (15 of 133) of the control group (p = 0.02), driven by the difference of severe PAR. Conclusions The implementation of an MDCT annulus area sizing algorithm for TAVR reduces PAR. Three-dimensional aortic annular assessment and annular area sizing should be considered for TAVR. (C) 2013 by the American College of Cardiology Foundation
引用
收藏
页码:431 / 438
页数:8
相关论文
共 50 条
  • [31] Subclinical Leaflet Thrombosis in Transcatheter Aortic Valve Replacement Detected by Multidetector Computed Tomography - A Review of Current Evidence
    Rashid, Hashrul N.
    Brown, Adam J.
    McCormick, Liam M.
    Amiruddin, Ameera S.
    Be, Kim K.
    Cameron, James D.
    Nasis, Arthur
    Gooley, Robert P.
    CIRCULATION JOURNAL, 2018, 82 (07) : 1735 - 1742
  • [32] THE IMPACT OF ANNULUS ECCENTRICITY AND OVER-SIZING VALVE DEPLOYMENT FOR LESS PARAVALVULAR LEAKAGE AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT
    Nakao, Mana
    Mizutani, Kazuki
    Okai, Tsukasa
    Yoshida, Keiko
    Nishimura, Shinsuke
    Ito, Asahiro
    Iwata, Shinichi
    Takahashi, Yosuke
    Murakami, Takashi
    Shibata, Toshihiko
    Yoshiyama, Minoru
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1144 - 1144
  • [33] In Vivo Computed Tomography Sizing for Redo-Transcatheter Aortic Valve Replacement in Evolut Valves: Impact on Sizing, Feasibility, and Prosthesis-Patient Mismatch
    Okada, Atsushi
    Fukui, Miho
    Zaid, Syed
    Thao, Kiahltone R.
    Walser-Kuntz, Evan
    Stanberry, Larissa I.
    Burns, Marcus R.
    Koike, Hideki
    Wang, Cheng
    Phichaphop, Asa
    Lesser, John R.
    Cavalcante, Joao L.
    Sorajja, Paul
    Bapat, Vinayak N.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (08)
  • [34] INTEROBSERVER AND INTRAOBSERVER REPRODUCIBILITY OF AORTIC VALVAR COMPLEX MEASUREMENTS AND TRANSCATHETER AORTIC VALVE REPLACEMENT DEPLOYMENT ANGLES BY MULTIDETECTOR COMPUTED TOMOGRAPHY
    Heo, Ran
    Kalra, Dan
    Giambrone, Ashley
    Gomez, Millie J.
    Leipsic, Jonathon
    Wong, Shing-Chiu
    Salemi, Arash
    Minutello, Robert
    Bergman, Geoffrey W.
    Lin, Fay
    Min, James
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1216 - A1216
  • [35] Relationship of Annular Sizing Using Multidetector Computed Tomographic Imaging and Clinical Outcomes After Self-Expanding CoreValve Transcatheter Aortic Valve Replacement
    Popma, Jeffrey J.
    Gleason, Thomas G.
    Yakubov, Steven J.
    Harrison, J. Kevin
    Forrest, John K.
    Maini, Brijeshwar
    Ruiz, Carlos E.
    Pinto, Duane S.
    Costa, Marco
    Resar, Jon
    Conte, John
    Crestanello, Juan
    Chang, Yanping
    Oh, Jae K.
    Reardon, Michael J.
    Adams, David H.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (07)
  • [36] Is intra-procedure three-dimensional transesophageal echocardiogram an alternative to preprocedure multidetector computed tomography for the measurement of the aortic annulus in patients undergoing transcatheter aortic valve replacement?
    Hafiz, Abdul Moiz
    Medranda, Giorgio A.
    Kakouros, Nikolaos
    Patel, Jay
    Kahan, Jonathan
    Gubernikoff, George
    Ray, Beevash
    Paruchuri, Vijayapraveena
    DeLeon, Joshua
    Marzo, Kevin
    Calixte, Rose
    Gaztanaga, Juan
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2017, 34 (08): : 1195 - 1202
  • [37] Three-Dimensional Measurement of Aortic Annulus Dimensions Using Area or Circumference for Transcatheter Aortic Valve Replacement Valve Sizing: Does It Make a Difference?
    Papachristidis, Alexandros
    Papitsas, Michael
    Roper, Damian
    Wang, Yanzhong
    Dworakowski, Rafal
    Byrne, Jonathan
    Wendler, Olaf
    MacCarthy, Philip
    Monaghan, Mark J.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2017, 30 (09) : 871 - 878
  • [38] Comprehensive Myocardial Assessment by Computed Tomography Impact on Short-Term Outcomes After Transcatheter Aortic Valve Replacement
    Koike, Hideki
    Fukui, Miho
    Treibel, Thomas
    Stanberry, Larissa I.
    Cheng, Victor Y.
    Enriquez-Sarano, Maurice
    Schmidt, Stephanie
    Schelbert, Erik B.
    Wang, Cheng
    Okada, Atsushi
    Phichaphop, Asa
    Sorajja, Paul
    Bapat, Vinayak N.
    Leipsic, Jonathon
    Lesser, John R.
    Cavalcante, Joao L.
    JACC-CARDIOVASCULAR IMAGING, 2024, 17 (04) : 396 - 407
  • [39] Accuracy of aortic root annulus assessment with cardiac magnetic resonance in patients referred for transcatheter aortic valve implantation: a comparison with multidetector computed tomography
    Pontone, G.
    Andreini, D.
    Bertella, E.
    Mushtaq, S.
    Gripari, P.
    Cortinovis, S.
    Loguercio, M.
    Baggiano, A.
    Conte, E.
    Pepi, M.
    EUROPEAN HEART JOURNAL, 2013, 34 : 32 - 32
  • [40] Potential impact of dynamic automated CT aortic annular measurements on outcomes for transcatheter aortic valve replacement sizing
    Pritha Subramanyam
    Alan C. Legasto
    Subhi J. Al’Aref
    Shing Chiu Wong
    Quynh A. Truong
    The International Journal of Cardiovascular Imaging, 2020, 36 : 2291 - 2297