The Impact of Integration of a Multidetector Computed Tomography Annulus Area Sizing Algorithm on Outcomes of Transcatheter Aortic Valve Replacement A Prospective, Multicenter, Controlled Trial

被引:261
|
作者
Binder, Ronald K. [1 ]
Webb, John G. [1 ]
Willson, Alexander B. [1 ]
Urena, Marina [2 ]
Hansson, Nicolaj C. [3 ]
Norgaard, Bjarne L. [3 ]
Pibarot, Philippe [2 ]
Barbanti, Marco [1 ]
Larose, Eric [2 ]
Freeman, Melanie [1 ]
Dumont, Eric [2 ]
Thompson, Chris [1 ]
Wheeler, Miriam [1 ]
Moss, Robert R. [1 ]
Yang, Tae-hyun [1 ]
Pasian, Sergio [2 ]
Hague, Cameron J. [1 ]
Giang Nguyen [1 ]
Raju, Rekha [1 ]
Toggweiler, Stefan [1 ]
Min, James K. [4 ]
Wood, David A. [5 ]
Rodes-Cabau, Josep [2 ]
Leipsic, Jonathon [1 ]
机构
[1] Univ British Columbia, St Pauls Hosp, Vancouver, BC V5Z 1M9, Canada
[2] Univ Laval, Quebec Heart & Lung Inst, Quebec City, PQ, Canada
[3] Aarhus Univ, Hosp Skejby, Aarhus, Denmark
[4] Cedars Sinai Heart Inst, Los Angeles, CA USA
[5] Univ British Columbia, Vancouver Gen Hosp, Vancouver, BC V5Z 1M9, Canada
关键词
annulus area; multidetector computed tomography; transcatheter aortic valve replacement; transcatheter heart valve sizing; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; HEART-VALVE; IMPLANTATION; REGURGITATION;
D O I
10.1016/j.jacc.2013.04.036
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study prospectively investigated the impact of integration of a multidetector computed tomography (MDCT) annular area sizing algorithm on transcatheter aortic valve replacement (TAVR) outcomes. Background Appreciation of the 3-dimensional, noncircular geometry of the aortic annulus is important for transcatheter heart valve (THV) sizing. Methods Patients being evaluated for TAVR in 4 centers underwent pre-procedural MDCT. Recommendations for balloon-expandable THV size selection were based on an MDCT sizing algorithm with an optimal goal of modest annulus area oversizing (5% to 10%). Consecutive patients who underwent TAVR with the algorithm (MDCT group) were compared with consecutive patients without the algorithm (control group). The primary endpoint was the incidence of more than mild paravalvular regurgitation (PAR), and the secondary endpoint was the composite of in-hospital death, aortic annulus rupture, and severe PAR. Results Of 266 patients, 133 consecutive patients underwent TAVR (SAPIEN XT THV) in the MDCT group and 133 consecutive patients were in the control group. More than mild PAR was present in 5.3% (7 of 133) of the MDCT group and in 12.8% (17 of 133) in the control group (p = 0.032). The combined secondary endpoint occurred in 3.8% (5 of 133) of the MDCT group and in 11.3% (15 of 133) of the control group (p = 0.02), driven by the difference of severe PAR. Conclusions The implementation of an MDCT annulus area sizing algorithm for TAVR reduces PAR. Three-dimensional aortic annular assessment and annular area sizing should be considered for TAVR. (C) 2013 by the American College of Cardiology Foundation
引用
收藏
页码:431 / 438
页数:8
相关论文
共 50 条
  • [1] THE IMPACT OF INTEGRATION OF A COMPUTED TOMOGRAPHY ANNULUS AREA SIZING ALGORITHM ON CLINICAL OUTCOMES OF TRANSCATHETER AORTIC VALVE REPLACEMENT: A PROSPECTIVE, MULTICENTER, CONTROLLED TRIAL
    Binder, Ronald K.
    Webb, John
    Urena, Marina
    Hansson, Nicolaj
    Rodes-Cabau, Josep
    Norgaard, Bjarne L.
    Pibarot, Philippe
    Barbanti, Marco
    Larose, Eric
    Freeman, Melanie
    Dumont, Eric
    Thompson, Christopher
    Pasian, Sergio
    Giang Nguyen
    Raju, Rekha
    Toggweiler, Stefan
    Willson, Alexander B.
    Wood, David
    Leipsic, Jonathon
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1982 - E1982
  • [2] Multidetector computed tomography sizing of aortic annulus prior to transcatheter aortic valve replacement (TAVR): Variability and impact of observer experience
    Le Couteulx, S.
    Caudron, J.
    Dubourg, B.
    Cauchois, G.
    Dupre, M.
    Michelin, P.
    Durand, E.
    Eltchaninoff, H.
    Dacher, J-N
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2018, 99 (05) : 279 - 289
  • [3] Balloon vs Computed Tomography Sizing of the Aortic Annulus for Transcatheter Aortic Valve Replacement
    Condado, Jose F.
    Stewart, James
    Jensen, Hanna A.
    Lerakis, Stamatios
    Ko, Sung Min
    Stillman, Arthur
    Rajaei, Mohammad H.
    Mavromatis, Kreton
    Devireddy, Chandan
    Sarin, Eric
    Leshnower, Bradley G.
    Guyton, Robert
    Kaebnick, Brian
    Syed, Amjad
    Thourani, Vinod
    Block, Peter C.
    Babaliaros, Vasilis
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B267 - B268
  • [4] Conformational Pulsatile Changes of the Aortic Annulus Impact on Prosthesis Sizing by Computed Tomography for Transcatheter Aortic Valve Replacement
    Blanke, Philipp
    Russe, Maximillian
    Leipsic, Jonathon
    Reinoehl, Jochen
    Ebersberger, Ullrich
    Suranyi, Pal
    Siepe, Matthias
    Pache, Gregor
    Langer, Mathias
    Schoepf, U. Joseph
    JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (09) : 984 - 994
  • [5] Conformational pulsatile changes of the aortic annulus: impact on prosthesis sizing by computed tomography for transcatheter aortic valve replacement
    Blanke, P.
    Russe, M.
    Leipsic, J.
    Ebersberger, U.
    Siepe, M.
    Reinoehl, J.
    Suranyi, P.
    Langer, M.
    Schoepfl, U. J.
    EUROPEAN HEART JOURNAL, 2012, 33 : 89 - 90
  • [6] Aortic Annulus Diameter Determination by Multidetector Computed Tomography: Reproducibility, Applicability and Implications for Transcatheter Aortic Valve Replacement
    Gurvitch, Ronen
    Webb, John
    Ruan, Yen
    Johnson, Mark
    Hague, Cameron
    Willson, Alexander B.
    Toggweiller, Stefan
    Wood, David A.
    Ye, Jian
    Moss, Robert
    Thompson, Christopher
    Leipsic, Jonathon
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B39 - B39
  • [7] intravascular ultrasound versus multidetector computed tomography for annular sizing during transcatheter aortic valve replacement
    Abd El Hakim, D. E. D.
    Oluseun, A. O.
    Oluseun, A. O.
    Sasse, M.
    Sasse, M.
    Booker, O.
    Booker, O.
    Singh, S.
    Singh, S.
    Davis, J.
    Davis, J.
    Leesar, M.
    Leesar, M.
    EUROPEAN HEART JOURNAL, 2016, 37 : 52 - 53
  • [8] Balloon Versus Computed Tomography Sizing of the Aortic Annulus for Transcatheter Aortic Valve Replacement and the Impact of Left Ventricular Outflow Tract Calcification and Morphology on Sizing
    Condado, Jose F.
    Lerakis, Stamatios
    Stewart, James
    Jensen, Hanna
    Henry, Travis S.
    Ko, Sung Min
    Stillman, Arthur
    Rajaei, Mohammad H.
    Mavromatis, Kreton
    Devireddy, Chandan
    Sarin, Eric
    Leshnower, Brad
    Guyton, Robert
    Kaebnick, Brian
    Thourani, Vinod H.
    Block, Peter C.
    Babaliaros, Vasilis
    JOURNAL OF INVASIVE CARDIOLOGY, 2016, 28 (07): : 295 - 304
  • [9] Comparison of postoperative outcomes following multidetector computed tomography based vs transesophageal echocardiography based annulus sizing for transcatheter aortic valve replacement: A systematic review and meta-analysis
    Tang, Guozhang
    Lv, Qifeng
    He, Xiangqin
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2020, 37 (10): : 1617 - 1626
  • [10] Optimal annulus sizing approach for patients assigned for transcatheter aortic valve replacement with bicuspid aortic valve: comparison of echocardiographic and computed tomography derived measurement
    Wang, Y.
    EUROPEAN HEART JOURNAL, 2018, 39 : 98 - 98