Neutron/Gamma-ray Pulse Shape Discrimination with a CLYC Scintillator

被引:4
|
作者
Nie, Qiyuan [1 ,2 ]
Zhu, Jinfu [2 ]
Ma, Hao [2 ]
Zeng, Zhi [2 ]
Cheng, Jianping [2 ,3 ]
Li, Junli [2 ]
Zhang, Hui [2 ]
机构
[1] Tsinghua Univ, Minist Educ, Key Lab Particle & Radiat Imaging, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[3] Beijing Normal Univ, Coll Nucl Sci & Technol, Beijing 100875, Peoples R China
关键词
CLYC scintillator; pulse shape discrimination; Fisher linear discriminant; CS2LIYCL6-CE3+; LUMINESCENCE;
D O I
10.1109/nss/mic42101.2019.9059774
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Cs2LiYCl6:Ce3+ (CLYC) is a promising Li-based inorganic scintillator for its dual-mode detector capability to perform neutron detection and gamma spectroscopy. Pulse Shape Discrimination (PSD) between neutron and gamma-ray signals can achieve superior results owing to the fundamentally unique scintillation mechanisms within CLYC crystal. In this work, an 1x1 inch CLYC scintillator enriched with 95% Li-6 was used for simultaneous neutron and gamma-ray detection. Difference on pulse rise time between neutron and gamma-ray was found and its effects on traditional charge integration method were analyzed. A pulse shape discrimination (PSD) method based on Fisher linear discriminant was used to discriminate neutron and gamma-ray signals with different parts of waveform. The results show that positive effect on neutron and gamma-ray PSD appears when the integral window is well set based on the pulse rise time. Fisher classification achieves better figure-of-merit (FOM) of 4.6 +/- 0.1 compared to charge integration method. This method also shows reliable screening ability only using the short recording waveforms whose distinctions are mainly from the rising part. When the length of waveforms is 80 ns, the FOM is 2.3 +/- 0.1. This benefits the applications of CLYC in high count rate situations with short recording waveforms.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Assessment of photon detectors for a handheld gamma-ray and neutron spectrometer using Cs2LiYCl6:Ce (CLYC) scintillator
    Smith, M. B.
    McClish, M.
    Achtzehn, T.
    Andrews, H. R.
    Baginski, M. J.
    Best, D. J.
    Budden, B. S.
    Clifford, E. T. H.
    Dallmann, N. A.
    Dathy, C.
    Frank, J. M.
    Graham, S. A.
    Ing, H.
    Stonehill, L. C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 715 : 92 - 97
  • [32] On the shape of pulse spectra in gamma-ray bursts
    Ryde, F
    Svensson, R
    ASTROPHYSICAL JOURNAL, 1999, 512 (02): : 693 - 698
  • [33] Plastic Scintillators With Neutron/Gamma Pulse Shape Discrimination
    van Loef, Edgar V.
    Markosyan, Gary
    Shirwadkar, Urmila
    Shah, Kanai S.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (01) : 467 - 471
  • [34] Temperature Dependence of Neutron-Gamma Discrimination Based on Pulse Shape Discrimination Technique in a Ce : LiCaAlF6 Scintillator
    Watanabe, Kenichi
    Kondo, Yoshiyuki
    Yamazaki, Atsushi
    Uritani, Akira
    Iguchi, Tetsuo
    Kawaguchi, Noriaki
    Fukuda, Kentaro
    Ishidu, Sumito
    Yanagida, Takayuki
    Fujimoto, Yutaka
    Yoshikawa, Akira
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (02) : 959 - 962
  • [35] Neutron-gamma pulse shape discrimination for EJ301 liquid scintillator based on machine learning
    Xu, Jiahao
    Cheng, Wei
    Jia, Wenbao
    Chen, Qingbo
    Zhang, Ronghua
    Zhang, Yan
    Cheng, Can
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2024, 333 (02) : 905 - 916
  • [36] Neutron-gamma pulse shape discrimination for EJ301 liquid scintillator based on machine learning
    Jiahao Xu
    Wei Cheng
    Wenbao Jia
    Qingbo Chen
    Ronghua Zhang
    Yan Zhang
    Can Cheng
    Journal of Radioanalytical and Nuclear Chemistry, 2024, 333 : 905 - 916
  • [37] SCINTILLATION GAMMA-RAY SPECTROMETER WITH FAST NEUTRON DISCRIMINATION
    BOCHKAREV, VN
    NEFEDOV, VV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1964, (JUN) : 1018 - &
  • [38] Neutron/Gamma-Ray Discrimination through Measures of Fit
    Amiri, Moslem
    Prenosil, Vaclav
    Cvachovec, Frantisek
    2015 4TH INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2015,
  • [39] Neutron and Gamma Pulse Shape Discrimination by Robust Determination of the Decay Shape
    Baselga, Sergio
    Montbarbon, Eva
    APPLIED SCIENCES-BASEL, 2024, 14 (13):
  • [40] LIQUID ORGANIC SCINTILLATOR SYSTEM FOR MEASURING NEUTRON AND GAMMA-RAY SPECTRA
    STUPAR, TA
    ELSON, HR
    KEREIAKES, JG
    SHAPIRO, A
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1980, 31 (01): : 5 - 5