Application of partial discharge testing to motor and generator stator winding maintenance

被引:54
|
作者
Stone, GC
Sedding, HG
Costello, MJ
机构
[1] ONTARIO HYDRO TECHNOL,TORONTO,ON M8Z 5S4,CANADA
[2] TEXACO USA INC,BELLAIRE,TX 77402
关键词
D O I
10.1109/28.491498
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Deterioration of stator winding insulation continues to be one of the predominant-causes of large motor and generator failures. Over the past several years, practical methods have been developed for measuring the partial discharge activity in the high voltage insulation of stator windings, since partial discharges are a symptom of most of the insulation failure mechanisms in motors and generators rated 4 kV or more. The turbine generator analyzer (TGA) test has now been specifically developed to enable industrial plant staff to reliably perform a partial discharge test on operating motors and turbine generators. This paper presents several case studies of the use of these new partial discharge test technologies on rotating machines. Test results show that machines with deteriorated windings have a Partial discharge activity al least 30 times higher than good windings. The availability of these test methods enables plant staff to economically and reliably plan stator winding maintenance, avoid unexpected failures and often extend the time between major maintenance outages.
引用
收藏
页码:459 / 464
页数:6
相关论文
共 50 条
  • [41] Analysis of partial discharge to high voltage motor stator windings
    Kim, HD
    2001 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2001, : 340 - 343
  • [42] Subspecies analysis of partial discharge data from a generator stator conductor
    Wai, GL
    Bonwick, WJ
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1997, 144 (06) : 287 - 293
  • [43] Partial discharge measurements on hydro generator stator windings case studies
    Li, Shunyuan
    Chow, Jennifer M. Y.
    IEEE ELECTRICAL INSULATION MAGAZINE, 2007, 23 (03) : 5 - 15
  • [44] Analysis of partial discharge pulse propagation along generator stator windings
    Su, Q
    2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 269 - 272
  • [45] Continuous on-line partial discharge monitoring of generator stator windings
    Lloyd, BA
    Campbell, SR
    Stone, GC
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 1999, 14 (04) : 1131 - 1137
  • [46] Establishment of Partial Discharge Database for Identification of Winding Problem of Hydropower Generator
    Kuraishi, Takashi
    Miyazaki, Satoru
    2022 9TH INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2022, : 658 - 661
  • [47] GENERATOR STATOR CORE AND END WINDING VIBRATION
    RICHARDS.P
    HAWLEY, R
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1972, PA91 (04): : 1731 - &
  • [48] Turbo generator stator winding condition assessment
    Arshad, M
    Khaliq, A
    Islam, SM
    2004 International Conference on Power System Technology - POWERCON, Vols 1 and 2, 2004, : 1399 - 1403
  • [49] Diagnosis of stator winding insulation of large generator
    Xie, HK
    Bo, Y
    Hao, YP
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 274 - 277
  • [50] Assessment of the stator-winding insulation state based on partial-discharge measurements
    Obid, Matic
    Blazic, Bostjan
    ELEKTROTEHNISKI VESTNIK-ELECTROCHEMICAL REVIEW, 2014, 81 (04): : 179 - 186