Application of partial discharge testing to motor and generator stator winding maintenance

被引:54
|
作者
Stone, GC
Sedding, HG
Costello, MJ
机构
[1] ONTARIO HYDRO TECHNOL,TORONTO,ON M8Z 5S4,CANADA
[2] TEXACO USA INC,BELLAIRE,TX 77402
关键词
D O I
10.1109/28.491498
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Deterioration of stator winding insulation continues to be one of the predominant-causes of large motor and generator failures. Over the past several years, practical methods have been developed for measuring the partial discharge activity in the high voltage insulation of stator windings, since partial discharges are a symptom of most of the insulation failure mechanisms in motors and generators rated 4 kV or more. The turbine generator analyzer (TGA) test has now been specifically developed to enable industrial plant staff to reliably perform a partial discharge test on operating motors and turbine generators. This paper presents several case studies of the use of these new partial discharge test technologies on rotating machines. Test results show that machines with deteriorated windings have a Partial discharge activity al least 30 times higher than good windings. The availability of these test methods enables plant staff to economically and reliably plan stator winding maintenance, avoid unexpected failures and often extend the time between major maintenance outages.
引用
收藏
页码:459 / 464
页数:6
相关论文
共 50 条
  • [31] Investigations into the use of temperature detectors as stator winding partial discharge detectors
    Campbell, S. R.
    Stone, G. C.
    CONFERENCE RECORD OF THE 2006 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2006, : 369 - +
  • [32] Study of Partial Discharge Ultrasonic Wave Propagation in Generator Stator
    Yang, Yongming
    Duan, Xu
    Jiang, Fan
    MECHATRONICS AND APPLIED MECHANICS, PTS 1 AND 2, 2012, 157-158 : 53 - 57
  • [33] Inverter-embedded Partial Discharge Testing for Reliability Enhancement of Stator Winding Insulation in Low Voltage Machines
    Lee, Hyeon-jun
    Kim, Hanju
    Jeong, Jigyun
    Lee, Kibok
    Lee, Sang Bin
    Stone, Greg
    2021 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2021, : 4724 - 4730
  • [34] Inverter-Embedded Partial Discharge Testing for Reliability Enhancement of Stator Winding Insulation in Low Voltage Machines
    Lee, Hyeonjun
    Kim, Hanju
    Jeong, Jigyun
    Lee, Kibok
    Lee, Sang Bin
    Stone, Greg
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (02) : 2088 - 2096
  • [35] The use of moment features for recognition of partial discharges in generator stator winding models
    Gao, K
    Tan, KX
    Li, FQ
    Wu, CQ
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 290 - 293
  • [36] Investigation of partial discharge signal propagation, attenuation and pattern recognition in a stator winding
    Hudon, C
    Guuinic, P
    Audoli, A
    CONFERENCE RECORD OF THE 1996 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1996, : 201 - 205
  • [37] Advancements in interpreting partial discharge test results to assess stator winding condition
    Stone, GC
    Warren, V
    IEEE-IAS/PCA 2004 CEMENT INDUSTRY TECHNICAL CONFERENCE, CONFERENCE RECORD, 2004, : 61 - 65
  • [38] ASSESSMENT OF STATOR WINDING INSULATION CONDITION BASED ON ABSOLUTE PARTIAL DISCHARGE MAGNITUDE
    Sedding, H. G.
    Chan, C.
    Sasic, M.
    Stone, G. C.
    2023 INSUCON - 14TH INTERNATIONAL ELECTRICAL INSULATION CONFERENCE, 2023, : 19 - 23
  • [39] Methods of stator winding on-line: Diagnostics for large turbine generator preventive maintenance
    Poljakov, V
    Tsvetkov, V
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 1999, 14 (04) : 1646 - 1650
  • [40] Aging diagnosis of large generator stator winding insulation based on digital discharge detection
    Song, JC
    Yue, B
    Xie, HK
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 765 - 769