Autocalibrating Stokes polarimeter for materials characterization

被引:7
|
作者
Shinki, Masaya [2 ,3 ]
Ivanov, Mario T. [1 ]
Post, Joshua S. [1 ]
Vagle, Svein [3 ]
Cullen, Jay T. [2 ]
Hore, Dennis K. [1 ]
机构
[1] Univ Victoria, Dept Chem, Victoria, BC V8W 3V6, Canada
[2] Univ Victoria, Sch Earth & Ocean Sci, Victoria, BC V8W 3V6, Canada
[3] Fisheries Oceans Canada Inst Ocean Sci, Sidney, BC V8L 4B2, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
ROTATING-COMPENSATOR ELLIPSOMETRY; BOUND-CONSTRAINED OPTIMIZATION; SPECTROSCOPIC ELLIPSOMETRY; PROTEIN ADSORPTION; ALGORITHM; SURFACES; ANALYZER; ERRORS;
D O I
10.1364/AO.51.004113
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The design and construction of an ellipsometer based on a fixed-wavelength rotating-retarder Stokes polarimeter is described. Details are provided for an automated calibration scheme that provides two advantages for its operation. The first allows the phase of the lock-in amplifiers to be set based on the raw data, without a known calibration sample. The second illustrates that the relative amplitude of the acquired signals may also be calibrated in a similar manner. As an illustration, the refractive index and thickness of a glass cover slide are determined over a range of incident angles. (C) 2012 Optical Society of America
引用
收藏
页码:4113 / 4119
页数:7
相关论文
共 50 条
  • [41] A Stokes polarimeter based on four quadrant detector
    He Chao
    Chang Jin-Tao
    Wang Yong
    Liao Ran
    Xie Jun
    Ma Hui
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2016, 35 (01) : 57 - +
  • [42] On-Chip Polarimeter for Stokes Parameters Detection
    Zhou, Changyu
    Lei, Ting
    Yuan, Xiaocong
    2020 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE (ACP) AND INTERNATIONAL CONFERENCE ON INFORMATION PHOTONICS AND OPTICAL COMMUNICATIONS (IPOC), 2020,
  • [43] Microwave polarimeter with synchronous recording of stokes parameters
    Dvoyan G.V.
    Gulyan A.G.
    Martirosyan R.M.
    Pirumyan G.A.
    Agadzhanyan A.S.
    Radiophysics and Quantum Electronics, 2000, 43 (08) : 654 - 657
  • [44] Investigation of Azimuth Error of the Retarder of Stokes Polarimeter
    Dai Hu
    Yan Chang-xiang
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (07) : 2288 - 2293
  • [45] A Stokes polarimeter using two photoelastic modulators
    Wang, BLB
    List, J
    Rockwell, RR
    POLARIZATION MEASUREMENT, ANALYSIS, AND APPLICATIONS V, 2002, 4819 : 1 - 8
  • [46] Four camera complete Stokes imaging polarimeter
    Pezzaniti, J. Larry
    Chenault, David
    Roche, Mike
    Reinhardt, John
    Pezzaniti, Joseph P.
    Schultz, Howard
    POLARIZATION: MEASUREMENT, ANALYSIS, AND REMOTE SENSING VIII, 2008, 6972
  • [47] Liquid crystal-based Stokes polarimeter
    Hofmann, A
    POLARIZATION ANALYSIS, MEASUREMENT, AND REMOTE SENSING III, 2000, 4133 : 44 - 54
  • [48] Stokes polarimeter with polarization-dependent hologram
    Zhou, Hailong
    Wei, Yanxian
    Yu, Yu
    Dong, Jianji
    Zhang, Xinliang
    2019 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2019,
  • [49] VHF polarimeter with synchronous registration of the stokes parameters
    Dvoyan, G.A.
    Goulian, A.G.
    Martirossian, R.M.
    Piroumian, H.A.
    Agadjanian, A.S.
    Izvestiya Vysshikh Uchebnykh Zavedenij. Radiofizika, 2000, 43 (08): : 728 - 732
  • [50] Microbolometer-infrared imaging Stokes polarimeter
    Kudenov, Michael W.
    Pezzaniti, J. Larry
    Gerhart, Grant R.
    OPTICAL ENGINEERING, 2009, 48 (06)