Label-free electrochemical immunosensor based on K3[Fe(CN)6] as signal for facile and sensitive determination of tumor necrosis factor-alpha

被引:61
|
作者
Weng, Shaohuang [1 ]
Chen, Min [2 ,3 ]
Zhao, Chengfei [1 ]
Liu, Ailin [1 ]
Lin, Liqing [1 ]
Liu, Qicai [4 ]
Lin, Jianhua [3 ]
Lin, Xinhua [1 ]
机构
[1] Fujian Med Univ, Fac Pharm, Dept Pharmaceut Anal, Fuzhou 350004, Peoples R China
[2] Fujian Med Univ, Affiliated Union Hosp, Dept Orthoped Surg, Fuzhou 350004, Peoples R China
[3] Fujian Med Univ, Affiliated Hosp 1, Dept Bone Oncol, Fuzhou 350004, Peoples R China
[4] Fujian Med Univ, Affiliated Hosp 1, Dept Clin Lab, Fuzhou 350004, Peoples R China
来源
基金
中国国家自然科学基金; 美国国家科学基金会;
关键词
TNF-alpha; Electrochemical immunosensor; Label-free; K-3[Fe(CN)(6); Nafion; ULTRASENSITIVE DETECTION; GOLD NANOPARTICLES; HUMAN SERUM; IMMUNOASSAY; ANTIGEN; NANOCOMPOSITE; MICROSPHERES;
D O I
10.1016/j.snb.2013.03.141
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We herein proposed a novel, facile, and sensitive strategy for selective detection of tumor necrosis factor-alpha (TNF-alpha) using K-3[Fe(CN)(6)] as the label-free signal. A K-3[Fe(CN)(6)]-chitosan-glutaraldehyde system (K-CS-GA) capable of high signal indication was developed for the first time to improve the sensitivity of the electrochemical immunosensor. K-CS-GA acting as the signal indicator was first fixed on a glass carbon electrode to be the signal layer. Subsequently, nafion was used to cover the signal layer and immobilize mouse anti-human TNF-alpha onto the electrode. The target TNF-alpha captured onto the electrode through immunoreactions efficiently induced the current response of the electrode due to the non-conducting biomoleculars. TNF-alpha was detected by monitoring the electrode current response in PBS using cyclic voltammetry (CV), which proved to be sensitive to varying concentrations of TNF-alpha. The decreases of anodic currents were proportional to the logarithm of the antigen concentrations in the range of 0.02-34 ng/ml with the detection limit of 10 pg/ml. The proposed immunosensor not only demonstrated high sensitivity, good selectivity, acceptable stability, and reproducibility, but also exhibited potential applications in clinical protein diagnostics. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 44 条
  • [31] A "Clickable" Electrodeposited Polymer Films Based on 3-ethynylthiophene for the Covalent Immobilization of Proteins. Application to a Label-free Electrochemical Immunosensor for Escherichia Coli and Staphylococcus Aureus Determination
    Svalova, T. S.
    Medvedeva, M., V
    Kozitsina, A. N.
    ELECTROANALYSIS, 2021, 33 (12) : 2469 - 2475
  • [32] Development of a highly sensitive aptamer-based electrochemical sensor for detecting saxitoxin based on K3Fe(CN)6 regulated silver nanoparticles
    Zeng, Wei
    Tang, Xuemei
    Wu, Ting
    Han, Bingjun
    Wu, Long
    ANALYTICA CHIMICA ACTA, 2024, 1287
  • [33] Constructing a label-free electrochemical biosensor based on magnetic α-Fe 2 O 3 /Fe 3 O 4 heterogeneous nanosheets for the sensitive detection of VKORC1*2 gene
    Wang, Jie
    Ouyang, Hezhong
    Xu, Zhihao
    Sun, Lei
    He, Dawei
    Liu, Ruijiang
    ARABIAN JOURNAL OF CHEMISTRY, 2024, 17 (08)
  • [34] Magnetic electrode-based label-free electrochemical impedance spectroscopy immunosensor for sensitive detection of human malignant melanoma markers using gold nanoparticles functionalized magnetic graphene sheets as signal amplifier
    Wang, Yulan
    Guo, Zhankui
    Ma, Hongmin
    Li, Yueyun
    Cao, Wei
    Du, Bin
    Wei, Qin
    RSC ADVANCES, 2014, 4 (103): : 59106 - 59113
  • [35] A simple, sensitive, label-free electrochemical immunosensor based on the chitosan-coated silver/cerium oxide (CS@Ag/CeO2) nanocomposites for the detection of alpha-fetoprotein (AFP)
    Kayani, Farrukh Bashir
    Rafique, Saima
    Akram, Rizwan
    Hussain, Mozaffar
    Bashir, Shazia
    Nasir, Rubina
    Khan, Jan Sher
    NANOTECHNOLOGY, 2023, 34 (26)
  • [36] An electrochemical impedimetric immunosensor for label-free detection of Campylobacter jejuni in diarrhea patients' stool based on O-carboxymethylchitosan surface modified Fe3O4 nanoparticles
    Huang, Jinlin
    Yang, Gongjun
    Meng, Wenjing
    Wu, Liping
    Zhu, Aiping
    Jiao, Xin'an
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (05): : 1204 - 1211
  • [37] Signal amplification strategy of label-free ultrasenstive electrochemical immunosensor based ternary Ag/TiO2/rGO nanocomposites for detecting breast cancer biomarker CA 15-3
    Shawky, Ahmed M.
    El-Tohamy, Maha
    MATERIALS CHEMISTRY AND PHYSICS, 2021, 272
  • [38] Electrochemical performance of asymmetric supercapacitor with binder-free CoxMn3-xSe4 and radish-derived carbon electrodes using K3[Fe (CN)6] additive in electrolyte
    Das, Amit Kumar
    Shankar, Edugulla Girija
    Ramulu, Bhimanaboina
    Yu, Jae Su
    CHEMICAL ENGINEERING JOURNAL, 2022, 448
  • [39] A label-free electrochemical aptasensor based on platinum@palladium nanoparticles decorated with hemin-reduced graphene oxide as a signal amplifier for glypican-3 determination
    Li, Guiyin
    Li, Wenzhan
    Li, Shengnan
    Li, Xinhao
    Yao, Xiaoqing
    Xue, Wen
    Liang, Jintao
    Chen, Jiejing
    Zhou, Zhide
    BIOMATERIALS SCIENCE, 2022, 10 (23) : 6804 - 6817
  • [40] A label-free electrochemical immnunosensor based on signal magnification of oxygen reduction reaction catalyzed by uniform PtCo nanodendrites for highly sensitive detection of carbohydrate antigen 15-3
    Ge, Xin-Yue
    Feng, Yi-Ge
    Cen, Shi-Yun
    Wang, Ai-Jun
    Mei, Li-Ping
    Luo, Xiliang
    Feng, Jiu-Ju
    ANALYTICA CHIMICA ACTA, 2021, 1176