A testing set-up for a micro-analysis positron beam facility

被引:2
|
作者
Jorgensen, LV
van Veen, A
Schut, H
Winkelman, A
Kruit, P
机构
[1] Delft Univ Technol, Inst Interfac Reactor, NL-2629 JB Delft, Netherlands
[2] Delft Univ Technol, Dept Appl Phys, NL-2628 CJ Delft, Netherlands
关键词
positron; particle optics; positron moderation;
D O I
10.1016/S0168-9002(98)01567-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A description is given of an electrostatically guided positron beam set-up designed for testing the performance of a remoderation stage in a positron micro-beam facility. In this set-up positrons from a 15 mCi Na-22 source are moderated in a 3.5 mu m thick tungsten foil and focused onto the entrance of a 90 degrees cylindrical mirror deflector. At the exit of the deflector the positrons are focused onto a micro-channel plate with phosphor screen assembly in order to characterise the beam diameter and intensity at the entrance of the remoderation stage. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:131 / 135
页数:5
相关论文
共 50 条
  • [31] Set-up for dynamic testing of ADCs using the histogram method
    Brás, V
    Ramos, HMG
    ICEMI'2001: FIFTH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT AND INSTRUMENTS, VOL 1, CONFERENCE PROCEEDINGS, 2001, : 16 - 20
  • [32] TESTING SYSTEM SET-UP TO EVALUATE ACOUSTIC INDUCED VIBRATION
    Mann, . J. Adin, III
    Eilers, Daniel
    Jackson, Trent
    Swindell, Rob
    Middleton, Christopher
    Arnett, David
    Horder, Nicolas
    Izuchi, Hisao
    Evans, Geoff
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, 2016, VOL 4, 2017,
  • [33] Set-up optimization for arm experimental test of a positron source using channeling
    Baier, VN
    Bukin, AD
    Dimova, TV
    Druzhinin, VP
    Dubrovin, MS
    Golubev, VB
    Serednyakov, SI
    Shary, VV
    Strakhovenko, VM
    Artru, X
    Chevallier, M
    Kirsch, R
    Poizat, JC
    Remillieux, J
    Chehab, R
    Jejcic, A
    Silva, J
    Major, J
    Potylitsin, AP
    Vnukov, IE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 145 (1-2): : 221 - 229
  • [34] THE MERITS OF THE SET-UP OR RIGID BOX - IT AFFORDS PRODUCT PROTECTION AND DISPLAY FACILITY
    DAY, FT
    CONFECTIONERY PRODUCTION, 1981, 47 (06): : 311 - 312
  • [35] Progress toward "optical beam induced noise" measurement set-up
    Routoure, JM
    Méchin, L
    Flament, S
    Noise and Fluctuations, 2005, 780 : 681 - 684
  • [36] Dynamic shape control of flexural beam vibrations: An experimental set-up
    Pichler, U
    Irschik, H
    Krommer, M
    SMART STRUCTURES AND MATERIALS 2001: MODELING, SIGNAL PROCESSING, AND CONTROL IN SMART STRUCTURES, 2001, 4326 : 408 - 415
  • [37] The Influence of Time of Day On Set-Up Errors in External Beam Radiotherapy
    Valakh, V.
    Day, E.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [38] A MATHEMATICAL SET-UP LEADING TO ANALYSIS OF A CLASS OF DESIGNS
    Nandi, H. K.
    SANKHYA, 1947, 8 : 172 - 176
  • [39] ELECTRON BEAM MICRO-ANALYSIS OF SOME PLUTONIUM-IRON ALLOYS
    SCOTT, VD
    JOURNAL OF NUCLEAR MATERIALS, 1961, 3 (03) : 284 - 293
  • [40] Set-up and Implementation of a Recuperative Stand for Testing a Filtering and Regeneration System
    Bitoleanu, Alexandru
    Popescu, Mihaela
    Suru, Vlad Constantin
    Puncea, Oana
    2017 INTERNATIONAL CONFERENCE ON ELECTROMECHANICAL AND POWER SYSTEMS (SIELMEN), 2017, : 489 - 494