A testing set-up for a micro-analysis positron beam facility

被引:2
|
作者
Jorgensen, LV
van Veen, A
Schut, H
Winkelman, A
Kruit, P
机构
[1] Delft Univ Technol, Inst Interfac Reactor, NL-2629 JB Delft, Netherlands
[2] Delft Univ Technol, Dept Appl Phys, NL-2628 CJ Delft, Netherlands
关键词
positron; particle optics; positron moderation;
D O I
10.1016/S0168-9002(98)01567-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A description is given of an electrostatically guided positron beam set-up designed for testing the performance of a remoderation stage in a positron micro-beam facility. In this set-up positrons from a 15 mCi Na-22 source are moderated in a 3.5 mu m thick tungsten foil and focused onto the entrance of a 90 degrees cylindrical mirror deflector. At the exit of the deflector the positrons are focused onto a micro-channel plate with phosphor screen assembly in order to characterise the beam diameter and intensity at the entrance of the remoderation stage. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:131 / 135
页数:5
相关论文
共 50 条
  • [21] Student laboratory set-up for optical fiber testing
    Gajda, J
    Niesterowicz, A
    TECHNOLOGY AND APPLICATIONS OF LIGHT GUIDES, 1997, 3189 : 153 - 157
  • [22] Set-Up for Standardized Testing of Visual Acuity.
    Krochmann, Juergen
    Stadahl, Peter
    1600, (44):
  • [23] A modified set-up to reduce background spectra in the CDBS positron spectrometer
    Mahdi Ghasemifard
    Misagh Ghamari
    The European Physical Journal Plus, 136
  • [24] Low-energy positron-molecule scattering set-up
    Rajch, E
    Jaworek, A
    Karwasz, G
    Brusa, RS
    Bettonte, M
    Mariazzi, S
    Zecca, A
    ATOMIC AND MOLECULAR PHYSICS, 2003, 5258 : 190 - 193
  • [25] A modified set-up to reduce background spectra in the CDBS positron spectrometer
    Ghasemifard, Mahdi
    Ghamari, Misagh
    EUROPEAN PHYSICAL JOURNAL PLUS, 2021, 136 (12):
  • [26] Mathematical model of the electronuclear set-up on the beam of JINR synchrotron
    Barashenkov, VS
    Kumawat, H
    Lobanova, VA
    Kumar, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 217 (02): : 352 - 360
  • [27] Improving defect localization techniques with laser beam with specific analysis and set-up modules
    Llido, R.
    Gomez, J.
    Goubier, V.
    Haller, G.
    Pouget, V.
    Lewis, D.
    2012 IEEE INTERNATIONAL RELIABILITY PHYSICS SYMPOSIUM (IRPS), 2012,
  • [28] FAST BEAM CHAMBERS OF THE SET-UP ISTRA-M
    GUSHCHIN, EM
    KOMISSAROV, EV
    MUSIENKO, YV
    POBLAGUEV, AA
    SERDYUK, VZ
    ZALIKHANOV, BZ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 351 (2-3): : 345 - 348
  • [29] ANALYSIS AND OPTIMIZATION OF A HYBRID TESTING METHODOLOGY USING A SMALL-SCALE SET-UP
    van Vugt, G.
    Henriques, J.
    Vandoren, B.
    Degee, H.
    XII INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS, EURODYN 2023, 2024, 2647
  • [30] Wavepod a transmission for wave energy converters - set-up and testing
    Diessel, Dominic
    Bryans, Garth
    Verdegem, Louis
    Murrenhoff, Hubertus
    INTERNATIONAL JOURNAL OF FLUID POWER, 2015, 16 (02) : 75 - 82