Quality control of angular tube current modulation

被引:1
|
作者
Redzic, M. [1 ]
Beganovic, A. [2 ]
Civa, L. [3 ]
Jasic, R. [2 ]
Skopljak-Beganovic, A. [2 ]
Vegar-Zubovic, S. [4 ]
机构
[1] Inst Qual Control, Mostar, Bosnia & Herceg
[2] Sarajevo Univ, Dept Radiat Protect & Med Phys, Clin Ctr, Sarajevo, Bosnia & Herceg
[3] Sarajevo Sch Sci & Technol, Med Sch, Sarajevo, Bosnia & Herceg
[4] Sarajevo Univ, Clin Radiol, Clin Ctr, Sarajevo, Bosnia & Herceg
关键词
quality control; tube current modulation; computed tomography; dosimetry; radiation; CT; SYSTEM;
D O I
10.1007/978-981-10-4166-2_85
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Automatic exposure control (AEC) techniques in computed tomography (CT) have been defined as automatic modulation of tube current in the x-y plane (angular AEC), along the z-axis (z-axis AEC) or both (combined AEC), according to the size and attenuation characteristics of the body region being scanned. These techniques should provide constant image quality while lowering the radiation dose to patients. Although AEC is an important feature of all modern CT units, standard methodology for quality control of AEC does not exist. Aim of the paper was to provide reliable quality control (QC) method for AEC techniques used in CT. Change of tube current during the CT examination happens only if the scan projection radiogram (SPR) shows different size and attenuation characteristics of the object being scanned. In order to maintain repeatability of the modulation we used standard polymethyl methacrylate (PMMA) dosimetry phantom, placed with flat side along the z-axis. After SPR was taken, phantom was removed, and CT solid-state detector was placed in the isocenter. Measurements were performed in axial mode, one slice only, for different positions along the z-axis. Dose rates measured in the isocenter, that are proportional to tube current, were found depending on the phantom geometry. In the phantom center the width of rectangle is the same as the diameter of the cylindrical phantom (32 cm), while height corresponds to the cylinder thickness (15 cm). Results show that during the rotation the current is highest when the tube is positioned at the x-axis, and lowest when tube is crossing the y-axis. However, when the detector is moved to position z = 14.1 cm, tube current (air kerma rate) does not change during the rotation. The methodology presented in this study could be used as a basis for defining the QC procedure for TCM. The results are consistent with the expected outcomes.
引用
收藏
页码:563 / 567
页数:5
相关论文
共 50 条
  • [1] Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis
    Rizzo, S
    Kalra, M
    Schmidt, B
    Dalal, T
    Suess, C
    Flohr, T
    Blake, M
    Saini, S
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (03) : 673 - 679
  • [2] Online Angular Tube Current Modulation in X-Ray Computed Tomography: Can Tube Current Be Modulated Appropriately?
    Matsubara, K.
    Koshida, H.
    Takata, T.
    Horii, J.
    Iida, H.
    Koshida, K.
    Matsui, O.
    Fukuda, A.
    MEDICAL PHYSICS, 2012, 39 (06) : 3619 - 3619
  • [3] A Novel Phantom to Evaluate Longitudinal and Angular Automatic Tube Current Modulation (ATCM) in CT
    Merzan, D.
    Bujila, R.
    Nowik, P.
    MEDICAL PHYSICS, 2015, 42 (06) : 3643 - 3643
  • [4] Comparison of angular and XYZ-axes automatic tube current modulation techniques with constant tube current CT scanning of the abdomen and pelvis
    Rizzo, S
    Kalra, MK
    Dalal, T
    Schmidt, B
    Suess, C
    Flohr, T
    Blake, MA
    Saini, S
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 29 - 29
  • [5] Relating Noise to Image Quality Indicators in CT Examinations With Tube Current Modulation
    Solomon, Justin B.
    Li, Xiang
    Samei, Ehsan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (03) : 592 - 600
  • [6] Dose reduction and image quality in MDCT colonography using tube current modulation
    Graser, A.
    Wintersperger, B. J.
    Suess, C.
    Reiser, M. F.
    Becker, C. R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (03) : 695 - 701
  • [7] Comparison of Image Quality and Radiation Dose between Fixed Tube Current and Combined Automatic Tube Current Modulation in Craniocervical CT Angiography
    Lee, E. J.
    Lee, S. K.
    Agid, R.
    Howard, P.
    Bae, J. M.
    terBrugge, K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (09) : 1754 - 1759
  • [8] Automatic exposure control in CT: the effect of patient size, anatomical region and prescribed modulation strength on tube current and image quality
    Antonios E. Papadakis
    Kostas Perisinakis
    John Damilakis
    European Radiology, 2014, 24 : 2520 - 2531
  • [9] Automatic exposure control in CT: the effect of patient size, anatomical region and prescribed modulation strength on tube current and image quality
    Papadakis, Antonios E.
    Perisinakis, Kostas
    Damilakis, John
    EUROPEAN RADIOLOGY, 2014, 24 (10) : 2520 - 2531
  • [10] Prospective Optimization of CT under Tube Current Modulation: II. Image Quality
    Tian, Xiaoyu
    Wilson, Josh
    Frush, Donald
    Samei, Ehsan
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033