Comparison of a gel microcolumn assay with the conventional tube test for red blood cell alloantibody titration

被引:19
|
作者
Finck, Rachel [1 ]
Lui-Deguzman, Carrie [1 ]
Teng, Shih-Mao [1 ]
Davis, Rebecca [1 ]
Yuan, Shan [1 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Pathol & Lab Med, Los Angeles, CA 90095 USA
关键词
ANTIBODY TITRATIONS; PERFORMANCE; PREGNANCY; TITER;
D O I
10.1111/j.1537-2995.2012.03793.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Titration is a semiquantitative method used to estimate red blood cell (RBC) alloantibody reactivity. The conventional tube test (CTT) technique is the traditional method for performing titration studies. The gel microcolumn assay (GMA) is also a sensitive method to detect RBC alloantibodies. The aim of this study was to compare a GMA with the CTT technique in the performance of Rh and K alloantibody titration. STUDY DESIGN AND METHODS: Patient serum samples that contained an RBC alloantibody with a singular specificity were identified by routine blood bank workflow. Parallel titration studies were performed on these samples by both the CTT method and a GMA (ID-Micro Typing System anti-IgG gel card, Micro Typing Systems, Inc., an Ortho-Clinical Diagnostics Company). RESULTS: Forty-eight samples were included, including 11 anti-D, five anti-c, 13 anti-E, one anti-C, three anti-e, and 15 anti-K. Overall, the two methods generated identical results in 21 of 48 samples. For 42 samples (87.5%) the two methods generated results that were within one serial dilution, and for the remaining six samples, results were within two dilutions. CONCLUSION: GMA systems may perform comparably to the CTT in titrating alloantibodies to Rh and Kell antigens.
引用
收藏
页码:811 / 815
页数:5
相关论文
共 50 条
  • [21] Detection of red blood cell alloantibodies by gel centrifugation test
    Lehmann, R
    Kiefel, V
    TRANSFUSION MEDICINE AND HEMOTHERAPY, 2003, 30 (03) : 117 - 122
  • [22] Comparison study between routine tube test (LISS), PeG tube test, gel technology and solid phase red cell adherence assays.
    Reilly, B
    DePalma, H
    Cosgrove, P
    Parsi, M
    Grima, K
    TRANSFUSION, 1997, 37 (09) : S256 - S256
  • [23] COMPARISION OF MICROCOLUMN GEL ASSAY AND TUBE TEST FOR IDENTIFICATION OF ANTI-D ANTIBODY AMONG RH NEGATIVE PREGNANTWOMEN IN NEPAL
    Silwal, Pramita
    Paudel, Yuba Raj
    EXPERIMENTAL HEMATOLOGY, 2018, 64 : S104 - S104
  • [24] Gel methodology: A progressive test method for red blood cell phenotyping
    Pothiawala, M.
    Madden, P.
    TRANSFUSION, 2006, 46 (09) : 215A - 215A
  • [25] Comparison of the modified antiglobulin tube and gel microcolumn agglutination methods for testing acid eluates
    Pitts, RM
    Mueller, D
    Selbie, L
    Middleton, L
    Thomas, W
    TRANSFUSION, 2003, 43 (09) : 103A - 104A
  • [26] Performance of acid elution test by conventional tube test technique and gel test.
    Novaretti, MCZ
    Silveira, EJ
    Bonifacio, SL
    Dorlhiac-Llacer, PE
    Chamone, D
    TRANSFUSION, 2002, 42 (09) : 110S - 110S
  • [27] COMPARATION OF CONVENTIONAL TUBE METHOD WITH GEL COLUMN METHOD FOR ANTI-A/B TITRATION
    Hecimovic, A.
    Haspl, Hundric Z.
    Loncar, Jurakovic N.
    Galic, Kruhonja Z.
    Jagnjic, S.
    Balija, M.
    Jukie, I
    VOX SANGUINIS, 2013, 105 : 203 - 203
  • [28] Comparison of Conventional Tube Test and a Novel Gel Method to Detect C3d in the Direct Antiglobulin Test
    Vazquez-Gomez, G.
    Parsons, J.
    Peterson, T.
    Keller, M.
    Billingsley, K.
    Amniai, L.
    Roback, J.
    Chiu, J.
    TRANSFUSION, 2023, 63 : 178A - 179A
  • [29] Detection of canine red blood cell antigen and antibodies by gel test.
    Bendali-Ahcene, S
    Chabanne, L
    Fournel, C
    Bonnefont, C
    Monier, JC
    Rigal, D
    REVUE DE MEDECINE VETERINAIRE, 1998, 149 (04) : 301 - +
  • [30] Comparison of Conventional Tube and Gel-Based Agglutination Tests for AB System Blood Typing in Cat
    Spada, Eva
    Perego, Roberta
    Baggiani, Luciana
    Proverbio, Daniela