Assessing the Performance of Handheld Glucose Testing for Critical Care

被引:15
|
作者
Kost, Gerald J. [1 ,2 ]
Tran, Nam K. [1 ,2 ]
Louie, Richard F. [1 ,2 ]
Gentile, Nicole L. [1 ,2 ]
Abad, Victor J. [3 ]
机构
[1] Univ Calif Davis, Point Care Testing Ctr Teaching & Res, Sch Med, Davis, CA 95616 USA
[2] Univ Calif Davis, Univ Calif Lawrence Livermore Natl Lab, Ctr Point Care Technol, Davis, CA 95616 USA
[3] Epsilon Grp LLC, Charlottesville, VA USA
关键词
D O I
10.1089/dia.2008.0049
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We assessed the performance of a point-of-care (POC) glucose meter system (GMS) with multitasking test strip by using the locally-smoothed (LS) median absolute difference (MAD) curve method in conjunction with a modified Bland-Altman difference plot and superimposed International Organization for Standardization (ISO) 15197 tolerance bands. We analyzed performance for tight glycemic control (TGC). Methods: A modified glucose oxidase enzyme with a multilayer-gold, multielectrode, four-well test strip (StatStrip (TM), NOVA Biomedical, Waltham, MA) was used. There was no test strip calibration code. Pragmatic comparison was done of GMS results versus paired plasma glucose measurements from chemistry analyzers in clinical laboratories. Venous samples (n = 1,703) were analyzed at 35 hospitals that used 20 types of chemistry analyzers. Erroneous results were identified using the Bland-Altman plot and ISO 15197 criteria. Discrepant values were analyzed for the TGC interval of 80-110 mg/dL. Results: The GMS met ISO 15197 guidelines; 98.6% (410 of 416) of observations were within tolerance for glucose <75 mg/dL, and for >= 75 mg/dL, 100% were within tolerance. Paired differences (handheld. minus reference) averaged -2.2 (SD 9.8) mg/dL; the median was -1 (range, -96 to 45) mg/dL. LS MAD curve analysis revealed satisfactory performance below 186 mg/dL; above 186 mg/dL, the recommended error tolerance limit (5 mg/dL) was not met. No discrepant values appeared. All points fell in Clarke Error Grid zone A. Linear regression showed y = 1.018x - 0.716 mg/dL, and r(2) = 0.995. Conclusions: LS MAD curves draw on human ability to discriminate performance visually. LS MAD curve and ISO 15197 performance were acceptable for TGC. POC and reference glucose calibration should be harmonized and standardized.
引用
收藏
页码:445 / 451
页数:7
相关论文
共 50 条
  • [1] Drug interference with glucose measurements on six handheld glucose meters and a portable glucose analyzer for point-of-care testing in critical care.
    Tang, ZP
    Du, XG
    Louie, RF
    Kost, GJ
    CLINICAL CHEMISTRY, 1999, 45 (06) : A31 - A32
  • [2] Critical Care Glucose Point-of-Care Testing
    Narla, S. N.
    Jones, M.
    Hermayer, K. L.
    Zhu, Y.
    ADVANCES IN CLINICAL CHEMISTRY, VOL 76, 2016, 76 : 97 - 121
  • [3] Handheld computers in critical care
    Lapinsky, SE
    Weshler, J
    Mehta, S
    Varkul, M
    Hallett, D
    Stewart, TE
    CRITICAL CARE, 2001, 5 (04): : 227 - 231
  • [4] Effects of pH on glucose measurements with handheld glucose meters and a portable glucose analyzer for point-of-care testing
    Tang, ZP
    Du, XG
    Louie, RF
    Kost, GJ
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2000, 124 (04) : 577 - 582
  • [5] Handheld computers in critical care
    Stephen E Lapinsky
    Jason Weshler
    Sangeeta Mehta
    Mark Varkul
    Dave Hallett
    Thomas E Stewart
    Critical Care, 5
  • [6] Multicenter study of oxygen-insensitive handheld glucose point-of-care testing in critical care hospital ambulatory patients in the United States and Canada
    Kost, GJ
    Vu, HT
    Lee, JH
    Bourgeois, P
    Kiechle, FL
    Martin, C
    Miller, SS
    Okorodudu, AO
    Podczasy, JJ
    Webster, R
    Whitlow, KJ
    CRITICAL CARE MEDICINE, 1998, 26 (03) : 581 - 590
  • [7] Evaluation of handheld computers in critical care
    Lapinsky, S
    Weshler, J
    Varkul, M
    Mehta, S
    Stewart, T
    NEW ASPECTS OF HIGH TECHNOLOGY IN MEDICINE, 2000, : 279 - 284
  • [8] Reliability of Critical Values Obtained By Point Of Care Glucose Testing
    Schifman, R.
    Renner, S.
    Cooper, E.
    Douros, E.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A98 - A98
  • [9] Effects of different hematocrit levels on glucose measurements with handheld meters for point-of-care testing
    Tang, ZP
    Lee, JH
    Louie, RF
    Kost, GJ
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2000, 124 (08) : 1135 - 1140
  • [10] Qualitative analysis of handheld computers in critical care
    Lapinsky, S
    Mehta, S
    Varkul, M
    Stewart, T
    JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2000, : 1060 - 1060