Stented bioprosthetic valve hemodynamics: Is the supra-annular implant better than the intra-annular?

被引:0
|
作者
Badano, LP [1 ]
Pavoni, D [1 ]
Musumeci, S [1 ]
Frassani, R [1 ]
Gianfagna, P [1 ]
Baldassi, M [1 ]
Tursi, V [1 ]
Mazzaro, E [1 ]
Zakja, E [1 ]
Fioretti, PM [1 ]
Livi, U [1 ]
机构
[1] Osped S Maria Misericordia, Cardiol Unit, Dept Cardiopulm Sci, I-33100 Udine, Italy
来源
JOURNAL OF HEART VALVE DISEASE | 2006年 / 15卷 / 02期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: The use of stented bioprostheses for aortic valve replacement (AVR) in elderly patients with a small aortic annulus may result in unsatisfactory hemodynamic performance of the prosthesis. To overcome this limitation, new bioprostheses have been designed for complete supra-annular implantation, but the actual hemodynamic advantage of the supra-annular implant over the intra-annular has not been fully investigated. Accordingly, the hemodynamic performance of the same stented bioprosthesis (except for sewing ring design) implanted in the supra-annular and conventional intra-annular seating was compared. Methods: Twenty-two patients received an intraannular implant, and 38 a supra-annular implant. Age (74 +/- 5 versus 76 5 years, p = 0.54), gender (55% versus 50% males, p 0.79) and body surface area (1.74 +/- 0.2 versus 1.81 +/- 0.2 m(2), P= 0.13) were similar in both subgroups, who underwent echocardiography at 8 +/- 2 and 6 +/- 2 months after surgery, respectively (p 0.09). Results: The two patient subgroups had similar preoperative left ventricular outflow tract diameters (2.06 +/- 0.2 and 2.1 +/- 0.2 cm; p = 0.62), average size of implanted prosthesis (21.0 and 21.3 mm; p = 0.44) and mean transprosthetic flow rate (246 +/- 70 and 218 +/- 58 ml/s; p = 0.12). Mean (8 +/- 3 and 19 8 mmHg, p < 0.0001), and peak (17 +/- 6 and 40 +/- 13 mmHg; p < 0.0001) transprosthetic gradients were lower, and mean effective orifice area (EOA) (1.78 +/- 0.4 and 1.45 +/- 0.5 cm(2) p = 0.006) was higher in patients with supra-annular implants than in those with intraannular. The incidence of patient-prosthesis mismatch (EOA index < 0.85 cm(2)/m(2)) decreased from 50% to 34% (p < 0.0001), with no case of severe mismatch using the supra-annular implant. During follow up, a left ventricular mass reduction occurred in patients with supra-annular implants (from 225 +/- 110 to 173 +/- 59 g/m(2); p < 0.03), but not in patients with intra-annular implants (173 +/- 62 and 186 +/- 64 g/m(2); p = 0.87) Conclusion: The study results showed that, compared to intra-annular implantation, supra-annular implantation of bioprosthetic stented valves in the aortic position was associated with a significantly better hemodynamic performance of the prosthesis and significant regression of left ventricular hypertrophy.
引用
收藏
页码:238 / 246
页数:9
相关论文
共 50 条
  • [41] Supra-annular Transcatheter Aortic Valve-in-valve Implantation for a Degenerative Bioprosthesis
    Pascual-Tejerina, Virginia
    Moreno, Raul
    Galeote, Guillermo
    REVISTA ESPANOLA DE CARDIOLOGIA, 2019, 72 (08): : 672 - 672
  • [42] Maximizing prosthetic valve size with the Top Hat® supra-annular aortic valve
    Aagaard, Jan
    Geha, Alexander S.
    JOURNAL OF HEART VALVE DISEASE, 2007, 16 (01): : 84 - 90
  • [43] Clinical and hemodynamic implications of supra-annular implant of biological aortic valves
    Badano, Luigi P.
    Zamorano, Jose Luis
    Pavonia, Daisy
    Tosoratti, Elena
    Baldassi, Mara
    Zakja, Edlira
    Gianfagna, Pasquale
    Fioretti, Paolo M.
    Livi, Ugolino
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2006, 7 (07) : 524 - 532
  • [44] Transcatheter mitral valve implantation: supra-annular and subvalvular fixation techniques
    Loger, Klaas
    Lutter, Georg
    Huenges, Katharina
    Frank, Derk
    Gross, Justus
    Cremer, Jochen
    Attmann, Tim
    Morlock, Michael
    Pokorny, Saskia
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 54 (06) : 1013 - 1021
  • [45] Incidence of Prosthesis-Patient Mismatch in Valve-in-Valve with a Supra-Annular Valve
    Alwan, Louhai
    Ruge, Hendrik
    Krane, Markus
    Prinzing, Anatol
    Noebauer, Christian
    Lange, Rudiger
    Erlebach, Magdalena
    THORACIC AND CARDIOVASCULAR SURGEON, 2023, 71 (08): : 632 - 640
  • [46] An Intra-Annular 'Hemispherical' Annuloplasty Frame for Aortic Valve Repair
    Rankin, J. Scott
    JOURNAL OF HEART VALVE DISEASE, 2010, 19 (01): : 97 - 103
  • [47] Supra-annular sizing for transcatheter valve implantation in bicuspid aortic stenosis
    Jeger, Raban
    Reuthebuch, Oliver
    Fahrni, Gregor
    Laborde, Jean-Claude
    Vogel, Rolf
    Kaiser, Christoph
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2018, 14 (02): : 187 - 190
  • [48] INTRA-SUPRA ANNULAR AORTIC VALVE AND COMPLETE SUPRA ANNULAR AORTIC VALVE: A LITERATURE REVIEW AND HEMODYNAMIC COMPARISON
    Zhang, M.
    Wu, Q. -C.
    SCANDINAVIAN JOURNAL OF SURGERY, 2010, 99 (01) : 28 - 31
  • [49] Annular and supra-annular structure assessments for transcatheter aortic valve replacement in patients with bicuspid aortic stenosis
    Liu, Jian-Di
    Luo, Xian-Du
    Zhou, Zhi-Peng
    Gong, Ren
    Wu, Yan-Qing
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2021, 22 (04) : 1157 - 1166
  • [50] Procedural Success, Valve Hemodynamics and Outcomes in Patients with Moderate Aortic Stenosis Undergoing Supra-Annular Transcatheter Aortic Valve Replacement
    Sharma, Ravi
    Laham, Roger J.
    Sorajja, Paul
    Shah, Binita
    Garcia, Santiago
    Jain, Renuka
    Fender, Eric
    Philip, Femi
    Eisenberg, Ruth
    Chetcuti, Stanley
    CIRCULATION, 2021, 144