Stented bioprosthetic valve hemodynamics: Is the supra-annular implant better than the intra-annular?

被引:0
|
作者
Badano, LP [1 ]
Pavoni, D [1 ]
Musumeci, S [1 ]
Frassani, R [1 ]
Gianfagna, P [1 ]
Baldassi, M [1 ]
Tursi, V [1 ]
Mazzaro, E [1 ]
Zakja, E [1 ]
Fioretti, PM [1 ]
Livi, U [1 ]
机构
[1] Osped S Maria Misericordia, Cardiol Unit, Dept Cardiopulm Sci, I-33100 Udine, Italy
来源
JOURNAL OF HEART VALVE DISEASE | 2006年 / 15卷 / 02期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: The use of stented bioprostheses for aortic valve replacement (AVR) in elderly patients with a small aortic annulus may result in unsatisfactory hemodynamic performance of the prosthesis. To overcome this limitation, new bioprostheses have been designed for complete supra-annular implantation, but the actual hemodynamic advantage of the supra-annular implant over the intra-annular has not been fully investigated. Accordingly, the hemodynamic performance of the same stented bioprosthesis (except for sewing ring design) implanted in the supra-annular and conventional intra-annular seating was compared. Methods: Twenty-two patients received an intraannular implant, and 38 a supra-annular implant. Age (74 +/- 5 versus 76 5 years, p = 0.54), gender (55% versus 50% males, p 0.79) and body surface area (1.74 +/- 0.2 versus 1.81 +/- 0.2 m(2), P= 0.13) were similar in both subgroups, who underwent echocardiography at 8 +/- 2 and 6 +/- 2 months after surgery, respectively (p 0.09). Results: The two patient subgroups had similar preoperative left ventricular outflow tract diameters (2.06 +/- 0.2 and 2.1 +/- 0.2 cm; p = 0.62), average size of implanted prosthesis (21.0 and 21.3 mm; p = 0.44) and mean transprosthetic flow rate (246 +/- 70 and 218 +/- 58 ml/s; p = 0.12). Mean (8 +/- 3 and 19 8 mmHg, p < 0.0001), and peak (17 +/- 6 and 40 +/- 13 mmHg; p < 0.0001) transprosthetic gradients were lower, and mean effective orifice area (EOA) (1.78 +/- 0.4 and 1.45 +/- 0.5 cm(2) p = 0.006) was higher in patients with supra-annular implants than in those with intraannular. The incidence of patient-prosthesis mismatch (EOA index < 0.85 cm(2)/m(2)) decreased from 50% to 34% (p < 0.0001), with no case of severe mismatch using the supra-annular implant. During follow up, a left ventricular mass reduction occurred in patients with supra-annular implants (from 225 +/- 110 to 173 +/- 59 g/m(2); p < 0.03), but not in patients with intra-annular implants (173 +/- 62 and 186 +/- 64 g/m(2); p = 0.87) Conclusion: The study results showed that, compared to intra-annular implantation, supra-annular implantation of bioprosthetic stented valves in the aortic position was associated with a significantly better hemodynamic performance of the prosthesis and significant regression of left ventricular hypertrophy.
引用
收藏
页码:238 / 246
页数:9
相关论文
共 50 条
  • [31] LOW-SECTIONED SUPRA-ANNULAR VALVE FOR MITRAL REPLACEMENT
    CASTILLOOLIVARES, JL
    GOITI, JJ
    OCONNOR, F
    NOJEK, C
    TELLEZ, G
    FIGUERA, D
    REVISTA ESPANOLA DE CARDIOLOGIA, 1977, 30 (01): : 23 - 26
  • [32] The Toronto root stentless valve in the subcoronary position is hemodynamically superior to the mosaic stented completely supra-annular bioprosthesis
    Bleiziffer, S
    Eichinger, WB
    Wagner, I
    Guenzinger, R
    Bauernschmitt, R
    Lange, R
    JOURNAL OF HEART VALVE DISEASE, 2005, 14 (06): : 814 - 821
  • [33] A modified technique for supra-annular implantation of prosthetic tricuspid valve
    Shunei Saito
    Akio Matsuura
    Ken Miyahara
    Haruki Takemura
    Shinichi Mizutani
    Masashi Toyama
    Ryohei Otsuka
    Toshikuni Yamamoto
    Indian Journal of Thoracic and Cardiovascular Surgery, 2020, 36 : 426 - 428
  • [34] Intra-annular mitral valve replacement in neonates and infants
    Brizard, Christian P.
    d'Udekem, Yves
    Eastaugh, Lucas J.
    Lane, Geoffrey K.
    Jones, Bryn O.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 149 (01): : 390 - U547
  • [35] The outcome of TAVI in patients with small annulus and the comparison between intra-annular and supra-annular devices in small anulus: From the analysis of the Japanese nationwide registry
    Meguro, K.
    Hashimoto, T.
    Yanagisawa, T.
    Kitamura, T.
    Ako, J.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1083 - 1083
  • [36] The Carpentier-Edwards stented supra-annular pericardial aortic valve prosthesis: clinical durability and hemodynamic performance
    Plume, SK
    Sanders, JH
    CURRENT OPINION IN CARDIOLOGY, 2002, 17 (02) : 183 - 187
  • [37] Supra-Annular Mitral Valve Replacement in an Infant With Infective Endocarditis
    Yamauchi, Sanae
    Iwai, Shigemitsu
    Tominaga, Yuji
    Kugo, Yosuke
    Hasegawa, Moyu
    Kayatani, Futoshi
    Takahashi, Kunihiko
    Aoki, Hisaaki
    Kawata, Hiroaki
    ANNALS OF THORACIC SURGERY, 2018, 105 (01): : E27 - E29
  • [38] Supra-Annular Mitral Valve Implantation in Very Small Children
    Giordano, Raffaele
    Cantinotti, Massimiliano
    Pak, Vitali
    Arcieri, Luigi
    Poli, Vincenzo
    Assanta, Nadia
    Moschetti, Riccardo
    Murzi, Bruno
    JOURNAL OF CARDIAC SURGERY, 2015, 30 (02) : 185 - 189
  • [39] The prevalence of leaflet thrombosis in intra-versus supra-annular transcatheter aortic valve prostheses
    Rashid, H.
    Amiruddin, A.
    Be, K. K.
    Nasis, A.
    Gooley, R.
    Cameron, J.
    Brown, A.
    EUROPEAN HEART JOURNAL, 2018, 39 : 1081 - 1082
  • [40] First Report of Supra-Annular Atrially Placed Bioprosthetic Mitral Valve Leak Closure Through Percutaneous Approach
    Zgheib, Ali Z.
    Gharzuddine, Walid S.
    Sawaya, Fadi J.