Stented bioprosthetic valve hemodynamics: Is the supra-annular implant better than the intra-annular?

被引:0
|
作者
Badano, LP [1 ]
Pavoni, D [1 ]
Musumeci, S [1 ]
Frassani, R [1 ]
Gianfagna, P [1 ]
Baldassi, M [1 ]
Tursi, V [1 ]
Mazzaro, E [1 ]
Zakja, E [1 ]
Fioretti, PM [1 ]
Livi, U [1 ]
机构
[1] Osped S Maria Misericordia, Cardiol Unit, Dept Cardiopulm Sci, I-33100 Udine, Italy
来源
JOURNAL OF HEART VALVE DISEASE | 2006年 / 15卷 / 02期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: The use of stented bioprostheses for aortic valve replacement (AVR) in elderly patients with a small aortic annulus may result in unsatisfactory hemodynamic performance of the prosthesis. To overcome this limitation, new bioprostheses have been designed for complete supra-annular implantation, but the actual hemodynamic advantage of the supra-annular implant over the intra-annular has not been fully investigated. Accordingly, the hemodynamic performance of the same stented bioprosthesis (except for sewing ring design) implanted in the supra-annular and conventional intra-annular seating was compared. Methods: Twenty-two patients received an intraannular implant, and 38 a supra-annular implant. Age (74 +/- 5 versus 76 5 years, p = 0.54), gender (55% versus 50% males, p 0.79) and body surface area (1.74 +/- 0.2 versus 1.81 +/- 0.2 m(2), P= 0.13) were similar in both subgroups, who underwent echocardiography at 8 +/- 2 and 6 +/- 2 months after surgery, respectively (p 0.09). Results: The two patient subgroups had similar preoperative left ventricular outflow tract diameters (2.06 +/- 0.2 and 2.1 +/- 0.2 cm; p = 0.62), average size of implanted prosthesis (21.0 and 21.3 mm; p = 0.44) and mean transprosthetic flow rate (246 +/- 70 and 218 +/- 58 ml/s; p = 0.12). Mean (8 +/- 3 and 19 8 mmHg, p < 0.0001), and peak (17 +/- 6 and 40 +/- 13 mmHg; p < 0.0001) transprosthetic gradients were lower, and mean effective orifice area (EOA) (1.78 +/- 0.4 and 1.45 +/- 0.5 cm(2) p = 0.006) was higher in patients with supra-annular implants than in those with intraannular. The incidence of patient-prosthesis mismatch (EOA index < 0.85 cm(2)/m(2)) decreased from 50% to 34% (p < 0.0001), with no case of severe mismatch using the supra-annular implant. During follow up, a left ventricular mass reduction occurred in patients with supra-annular implants (from 225 +/- 110 to 173 +/- 59 g/m(2); p < 0.03), but not in patients with intra-annular implants (173 +/- 62 and 186 +/- 64 g/m(2); p = 0.87) Conclusion: The study results showed that, compared to intra-annular implantation, supra-annular implantation of bioprosthetic stented valves in the aortic position was associated with a significantly better hemodynamic performance of the prosthesis and significant regression of left ventricular hypertrophy.
引用
收藏
页码:238 / 246
页数:9
相关论文
共 50 条
  • [1] Stented bioprosthetic valve haemodynamics. How much is the supra-annular implant better than the intra-annular one?
    Badano, L.
    Musumeci, S.
    Pavoni, D.
    Frassani, R.
    Mazzaro, E.
    Gianfagna, P.
    Fioretti, P. M.
    Livi, U.
    EUROPEAN HEART JOURNAL, 2005, 26 : 283 - 284
  • [2] The Prevalence of Leaflet Thrombosis in Intra-annular Versus Supra-annular Transcatheter Aortic Valve Prostheses
    Rashid, Hashrul
    Khav, Nancy
    Gooley, Rob
    Amiruddin, Ameera
    Nasis, Arthur
    Cameron, James
    Brown, Adam
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (15) : S50 - S50
  • [3] Comparison of the Early Results of Supra-Annular and Intra-Annular Aortic Valve Replacement in Isolated Aortic Valve Replacement
    Beyazal, Osman Fehmi
    Tokatlioglu, Tanzer
    Basar, Veysel
    Zengin, Ahmet
    Yanartas, Mehmed
    MEDICAL BULLETIN OF SISLI ETFAL HOSPITAL, 2024, 58 (01): : 23 - 29
  • [4] Supra-annular versus intra-annular prostheses in aortic valve replacement: impact on haemodynamics and clinical outcomes
    Kim, Sang Hyun
    Kim, Ho Jin
    Kim, Joon Bum
    Jung, Sung-Ho
    Choo, Suk Jung
    Chung, Cheol Hyun
    Lee, Jae Won
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2019, 28 (01) : 58 - 64
  • [5] Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Replacement With Supra-Annular and Intra-Annular Prosthesis
    Okuno, Taishi
    Khan, Faisal
    Asami, Masahiko
    Praz, Fabien
    Winkel, Mirjam
    Lanz, Jonas
    Huber, Adrian
    Grani, Christoph
    Raber, Lorenz
    Stortecky, Stefan
    Valgimigli, Marco
    Windecker, Stephan
    Pilgrim, Thomas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B739 - B739
  • [6] Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Replacement With Supra-Annular and Intra-Annular Prostheses
    Okuno, Taishi
    Khan, Faisal
    Asami, Masahiko
    Praz, Fabien
    Heg, Dik
    Winkel, Mirjam Gauri
    Lanz, Jonas
    Huber, Adrian
    Grani, Christoph
    Raber, Lorenz
    Stortecky, Stefan
    Valgimigli, Marco
    Windecker, Stephan
    Pilgrim, Thomas
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (21) : 2173 - 2182
  • [7] HEMODYNAMIC PERFORMANCE OF TRANSCATHETER HEART VALVES WITH SUPRA-ANNULAR OR INTRA-ANNULAR POSITION FOR TRANSCATHETER AORTIC VALVE-IN-VALVE IMPLANTATION
    Silaschi, Miriam
    Wendler, Olaf
    Seiffert, Moritz
    Castro, Liesa
    Schofer, Niklas
    Fink, Anna
    Reichenspurner, Hermann
    Blankenberg, Stefan
    MacCarthy, Philip
    Schaefer, Ulrich
    Conradi, Lenard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 128 - 128
  • [8] HAEMODYNAMIC PERFORMANCE OF SUPRA-ANNULAR VERSUS INTRA-ANNULAR TRANSCATHETER HEART VALVES IN FAILED BIOPROSTHESES
    Silaschi, M.
    Wendler, O.
    Castro, L.
    Aldalati, O.
    Reichenspurner, H.
    Blankenberg, S.
    Schaefer, U.
    MacCarthy, P.
    Conradi, L.
    HEART, 2016, 102 : A13 - A13
  • [9] Mechanism of Acute Lumen Gain During Transcatherer Aortic Valve Replacement With Valves of Supra-Annular versus Intra-Annular Design
    Kalinczuk, Lukasz
    Zielinski, Kamil
    Witkowski, Adam
    Mintz, Gary S.
    Sala, Zuzanna
    Swierczewski, Michal
    Dabrowski, Maciej
    Markiewicz, Michal G.
    Motyl, Daria
    Lazarczyk, Hubert
    Pregowski, Jerzy
    Michalowska, Ilona
    Demkow, Marcin
    Chmielak, Zbigniew
    CIRCULATION, 2018, 138
  • [10] Comparison of latest generation supra-annular and intra-annular self-expanding transcatheter heart valves
    Pellegrini, Costanza
    Rheude, Tobias
    Michel, Jonathan
    Alvarez-Covarrubias, Hector A.
    Wuensch, Sarah
    Mayr, N. Patrick
    Xhepa, Erion
    Kastrati, Adnan
    Schunkert, Heribert
    Joner, Michael
    Kasel, Markus
    JOURNAL OF THORACIC DISEASE, 2020, 12 (11) : 6769 - 6779