Transcatheter closure of patent ductus arteriosus using Gianturco coils in adolescents and adults

被引:20
|
作者
Wang, JK
Liau, CS
Huang, JJ
Hsu, KL
Lo, PH
Hung, JS
Wu, MH
Lee, YT
机构
[1] Natl Taiwan Univ Hosp, Dept Pediat, Taipei, Taiwan
[2] Natl Taiwan Univ Hosp, Dept Internal Med, Taipei, Taiwan
[3] China Med Coll Hosp, Dept Internal Med, Taichung, Taiwan
关键词
adolescents and adults; patent ductus arteriosus; transcatheter closure; Gianturco coil;
D O I
10.1002/ccd.10090
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We present the short- and intermediate-term results of transcatheter closure of patent ductus arteriosus with Gianturco coils in adolescents and adults. During a 5-year period, 55 patients (44 females, 11 males) with ages ranging from 14 to 72 years (median, 23) underwent attempted transcatheter closure of patent ductus with the Gianturco coils. The diameter of the narrowest segment of the ductus ranged from 0.8 to 7.6 mm (3.9 +/- 1.3 mm). The 55 patients were divided into three groups. Group I consisted of nine patients with a ductal diameter less than or equal to 3 mm, group II consisted of 27 patients with a ductal diameter > 3 mm but less than or equal to 4 mm, and group III consisted of 19 patients with a ductal diameter > 4 mm. Four- to five-loop Gianturco coils were used, which were deployed via retrograde aortic route. Multiple-coil technique was generally applied in group II patients. Balloon occlusion technique in combination with multiple-coil technique was generally used in group III patients. Deployment of coil was successful in 51 patients (93%) but failed in 4. The success rate of coil deployment in group I, II, and III were 100% (9/9), 96% (26/27), and 84% (16/19), respectively. A mean of 1.9 +/- 0.7 coils was deployed per patient. Of the four patients with unsuccessful coil deployment, three underwent surgery and one received implantation with Amplatzer duct occluder. Distal embolization of 21 coils occurred in 10 patients (3 in group II and 7 in group III), from whom 20 coils were retrieved with a gooseneck snare and 1 coil was removed during surgery. The mean diameter of ductus in the 10 patients with distal embolization was significantly larger than that in those without (5.2 +/- 1.4 vs. 3.7 +/- 1.1 mm; P < 0.01). Among the 51 patients with successful coil deployment, immediate complete closure was achieved in 20 (39%), while trivial to mild leak was present in 31 (61%). No significant complications were encountered. After a follow-up period ranging from 5 to 42 months, four patients had a small residual shunt and three underwent a second intervention with complete occlusion. None had left pulmonary artery stenosis documented with Doppler echocardiography. Transcatheter closure of ductus with the Gianturco coils is safe and feasible in the majority of adolescents and adults. Taking high embolization rate in patients with a ductus diameter > 4 mm into consideration, controlled-release coils, Buttoned device, or Amplatzer duct occluder can be a better choice. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:513 / 518
页数:6
相关论文
共 50 条
  • [31] Transcatheter closure of the patent ductus arteriosus using an amplatzer duct occluder in adults
    Lee, CH
    Leung, YL
    Chow, WH
    JAPANESE HEART JOURNAL, 2001, 42 (04): : 533 - 537
  • [32] Transcatheter Closure of Patent Ductus Arteriosus in Adults Using Amplatzer Duct Occluder
    Wang, Jou-Kou
    Wu, Mei-Hwan
    CIRCULATION, 2010, 122 (02) : E298 - E298
  • [33] Influence of ductal size on the results of transcatheter closure of patent ductus arteriosus with coils
    Fu, YC
    Hwang, B
    Jan, SL
    Lee, BC
    Ting, CT
    Chen, YT
    Chi, CS
    JAPANESE HEART JOURNAL, 2003, 44 (03): : 395 - 401
  • [34] Transcatheter closure of patent ductus arteriosus and ductus in children
    Irdem, Ahmet
    Kervancioglu, Mehmet
    Baspinar, Osman
    Kilinc, Metin
    EUROPEAN JOURNAL OF THERAPEUTICS, 2012, 18 (03): : 132 - 138
  • [35] Transcatheter closure of residual patent ductus arteriosus
    El-Saiedi, Sonia Ali
    Elshedoudy, Sahar Abdulla
    El-Sisi, Ammal Mahmoud
    Hanna, Baher Matta
    Fattouh, Aya Mohammed
    Hijazi, Ziyad
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 95 (01) : 78 - 82
  • [36] Comparison of transcatheter patent ductus arteriosus closure between children and adults
    Yasuhara, Jun
    Kuno, Toshiki
    Kumamoto, Takashi
    Kojima, Takuro
    Shimizu, Hiroyuki
    Yoshiba, Shigeki
    Kobayashi, Toshiki
    Sumitomo, Naokata
    HEART AND VESSELS, 2020, 35 (11) : 1605 - 1613
  • [37] Transcatheter Device Closure of Patent Ductus Arteriosus
    Sultan, Mehboob
    Ullah, Maad
    Sadiq, Nadeem
    Akhtar, Khurram
    Akbar, Hajira
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2014, 24 (10): : 710 - 713
  • [38] Comparison of transcatheter patent ductus arteriosus closure between children and adults
    Jun Yasuhara
    Toshiki Kuno
    Takashi Kumamoto
    Takuro Kojima
    Hiroyuki Shimizu
    Shigeki Yoshiba
    Toshiki Kobayashi
    Naokata Sumitomo
    Heart and Vessels, 2020, 35 : 1605 - 1613
  • [39] Transcatheter occlusion of patent ductus arteriosus using tornado platinum coils
    Suda, K
    Matsumura, M
    PEDIATRICS INTERNATIONAL, 2003, 45 (01) : 45 - 48
  • [40] Transcatheter closure of very large patent ductus arteriosus with the modified patent ductus arteriosus closure device.
    Zhang, F.
    Ge, J.
    Zhou, D.
    Guan, L.
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (8B): : 50D - 50D