Transcatheter closure of patent ductus arteriosus using Gianturco coils in adolescents and adults

被引:20
|
作者
Wang, JK
Liau, CS
Huang, JJ
Hsu, KL
Lo, PH
Hung, JS
Wu, MH
Lee, YT
机构
[1] Natl Taiwan Univ Hosp, Dept Pediat, Taipei, Taiwan
[2] Natl Taiwan Univ Hosp, Dept Internal Med, Taipei, Taiwan
[3] China Med Coll Hosp, Dept Internal Med, Taichung, Taiwan
关键词
adolescents and adults; patent ductus arteriosus; transcatheter closure; Gianturco coil;
D O I
10.1002/ccd.10090
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We present the short- and intermediate-term results of transcatheter closure of patent ductus arteriosus with Gianturco coils in adolescents and adults. During a 5-year period, 55 patients (44 females, 11 males) with ages ranging from 14 to 72 years (median, 23) underwent attempted transcatheter closure of patent ductus with the Gianturco coils. The diameter of the narrowest segment of the ductus ranged from 0.8 to 7.6 mm (3.9 +/- 1.3 mm). The 55 patients were divided into three groups. Group I consisted of nine patients with a ductal diameter less than or equal to 3 mm, group II consisted of 27 patients with a ductal diameter > 3 mm but less than or equal to 4 mm, and group III consisted of 19 patients with a ductal diameter > 4 mm. Four- to five-loop Gianturco coils were used, which were deployed via retrograde aortic route. Multiple-coil technique was generally applied in group II patients. Balloon occlusion technique in combination with multiple-coil technique was generally used in group III patients. Deployment of coil was successful in 51 patients (93%) but failed in 4. The success rate of coil deployment in group I, II, and III were 100% (9/9), 96% (26/27), and 84% (16/19), respectively. A mean of 1.9 +/- 0.7 coils was deployed per patient. Of the four patients with unsuccessful coil deployment, three underwent surgery and one received implantation with Amplatzer duct occluder. Distal embolization of 21 coils occurred in 10 patients (3 in group II and 7 in group III), from whom 20 coils were retrieved with a gooseneck snare and 1 coil was removed during surgery. The mean diameter of ductus in the 10 patients with distal embolization was significantly larger than that in those without (5.2 +/- 1.4 vs. 3.7 +/- 1.1 mm; P < 0.01). Among the 51 patients with successful coil deployment, immediate complete closure was achieved in 20 (39%), while trivial to mild leak was present in 31 (61%). No significant complications were encountered. After a follow-up period ranging from 5 to 42 months, four patients had a small residual shunt and three underwent a second intervention with complete occlusion. None had left pulmonary artery stenosis documented with Doppler echocardiography. Transcatheter closure of ductus with the Gianturco coils is safe and feasible in the majority of adolescents and adults. Taking high embolization rate in patients with a ductus diameter > 4 mm into consideration, controlled-release coils, Buttoned device, or Amplatzer duct occluder can be a better choice. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:513 / 518
页数:6
相关论文
共 50 条
  • [21] Transcatheter closure of patent ductus arteriosus in children weighing &lt;10kg with Gianturco coils using the balloon occlusion technique
    Dalvi, B
    Nabar, A
    Goyal, V
    Naik, A
    Kulkarni, H
    Ramakanthan, R
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1998, 44 (03): : 303 - 308
  • [22] Anterograde transcatheter occlusion of the patent ductus arteriosus with Gianturco coils - A new, effective and inexpensive technique
    DeMoor, M
    Lawrenson, J
    Fadley, FA
    Pribut, H
    Galal, O
    SOUTH AFRICAN MEDICAL JOURNAL, 1996, 86 : C143 - C146
  • [23] TRANSCATHETER CLOSURE OF PATENT DUCTUS ARTERIOSUS
    高伟
    周爱卿
    余志庆
    李奋
    王荣发
    黄美蓉
    Journal of Shanghai Second Medical University, 2002, (01) : 47 - 49
  • [24] Transcatheter closure of patent ductus arteriosus
    Alvarez J, Alejandro
    Carrillo R, Vanessa
    Sanhueza H, Eugenio
    Nazal L, Rodrigo
    REVISTA CHILENA DE PEDIATRIA-CHILE, 2012, 83 (06): : 577 - 581
  • [25] Transcatheter closure of patent ductus arteriosus
    Hess, J
    EUROPEAN HEART JOURNAL, 1997, 18 (03) : 359 - 360
  • [26] Transcatheter patent ductus arteriosus closure in an infant using the Gianturco-Grifka Vascular Occlusion Device
    Grifka, RG
    Vincent, JA
    Nihill, MR
    Ing, FF
    Mullins, CE
    AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (06): : 721 - 723
  • [27] Transcatheter closure of the patent ductus arteriosus
    Grifka, RG
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 61 (04) : 554 - 570
  • [28] TRANSCATHETER CLOSURE OF PATENT DUCTUS-ARTERIOSUS IN CHILDREN AND ADULTS
    WILSON, NJ
    NEUTZE, JM
    MAWSON, JB
    CALDER, AL
    NEW ZEALAND MEDICAL JOURNAL, 1993, 106 (960) : 299 - 301
  • [29] Transcatheter occlusion of native persistent ductus arteriosus using conventional Gianturco coils
    Alwi, M
    Kang, LM
    Samion, H
    Latiff, HA
    Kandavel, G
    Zambahari, R
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (10): : 1430 - &
  • [30] Transcatheter closure of large patent ductus arteriosus (>=4 mm) with multiple Gianturco coils: Immediate and mid-term results
    Hijazi, ZM
    Geggel, RL