Functional MRI of the Lungs Using Single Breath-Hold and Self-Navigated Ultrashort Echo Time Sequences

被引:11
|
作者
Heidenreich, Julius F. [1 ]
Veldhoen, Simon [1 ]
Metz, Corona [1 ]
Pereira, Lenon Mendes [1 ]
Benkert, Thomas [2 ]
Pfeuffer, Josef [2 ]
Bley, Thorsten A. [1 ]
Kostler, Herbert [1 ]
Weng, Andreas M. [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Siemens Healthcare, Dept Applicat Dev, Erlangen, Germany
来源
RADIOLOGY-CARDIOTHORACIC IMAGING | 2020年 / 2卷 / 03期
关键词
D O I
10.1148/ryct.2020190162
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate three-dimensional (3D) ultrashort echo time (UTE) MRI regarding image quality and suitability for functional image analysis using gradient-echo sequences in breath-hold and with self-navigation. Materials and Methods: In this prospective exploratory study, 10 patients (mean age, 21 years; age range, 558 years; five men) and 10 healthy control participants (mean age, 25 years; age range, 1039 years; five men) underwent 3D UTE MRI at 3.0 T. Imaging was performed with a prototypical stack-of-spirals 3D UTE sequence during single breath holds (echo time [TE], 0.05 msec) and with a self-navigated Koosh ball 3D UTE sequence at free breathing (TE, 0.03 msec). Image quality was rated on a four-point Likert scale. Edge sharpness was calculated. After semiautomated segmentation, fractional ventilation was calculated from MRI signal intensity (FVSI) and volume change (FVVol). The air volume fraction (AVF) was estimated from relative signal intensity (aortic blood signal intensity was used as a reference). Means were compared between techniques and participants. The Wilcoxon signed rank test and Spearman rank correlation were used for statistical analyses. Results: Image quality ratings were equal for both techniques. However, stack-of-spirals breath-hold UTE was more susceptible to motion and aliasing artifacts. Mean FVSI was higher during breath hold than at free breathing (mean +/- standard deviation in milliliters of gas per milliliters of parenchyma, 0.17 mL/mL +/- 0.06 [minimum, 0.07; maximum, 0.34] vs 0.11 mL/mL +/- 0.03 [minimum, 0.06; maximum, 0.17], P = .016). Mean FVSI and FVVol were in good agreement (mean difference: at breath hold, -0.008 [95% confidence interval {CI}: 0.007, -0.024]; rho = 0.97 vs free breathing, -0.004 [95% CI: 0.007, -0.016]; rho = 0.91). AVF correlated between both techniques (rho = 0.94). Conclusion: Breath-hold and self-navigated 3D UTE sequences yield proton densityweighted images of the lungs that are similar in quality, and both techniques are suitable for functional image analysis. Summary Three-dimensional ultrashort echo time gradient-echo sequences are promising tools for acquisition of proton density-weighted lung MR images within a single breath hold or at free breathing, providing high spatial resolution and allowing for functional image analysis such as ventilation or air volume fraction.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Distortion-Free Diffusion Imaging Using Self-Navigated Cartesian Echo-Planar Time Resolved Acquisition and Joint Magnitude and Phase Constrained Reconstruction
    Dai, Erpeng
    Lee, Philip K.
    Dong, Zijing
    Fu, Fanrui
    Setsompop, Kawin
    McNab, Jennifer A.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (01) : 63 - 74
  • [32] Reproducibility of left ventricular mass measurement using a half-fourier black-blood single-shot fast spin-echo sequence within a single breath hold: Comparison with a conventional multiple breath-hold gradient echo technique segmented in patients
    Vignaux, O
    Duboc, D
    Coste, J
    Argaud, C
    Carlier, P
    Le Roux, P
    Weber, S
    Legmann, P
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (06) : 654 - 660
  • [33] Evaluation of enthesopathy in psoriatic arthritis using a 3 testa MRI and using novel Ultrashort Time Echo (UTE) pulse sequences for imaging
    Hennigan, Stephanie L.
    Du, Jiang
    Chung, Christine
    Bydder, Graeme
    Kavanaugh, Arthur
    ARTHRITIS AND RHEUMATISM, 2007, 56 (12): : 4252 - 4253
  • [34] Combined Deep Learning-based Super-Resolution and Partial Fourier Reconstruction for Gradient Echo Sequences in Abdominal MRI at 3 Tesla: Shortening Breath-Hold Time and Improving Image Sharpness and Lesion Conspicuity
    Almansour, Haidara
    Herrmann, Judith
    Gassenmaier, Sebastian
    Lingg, Andreas
    Nickel, Marcel Dominik
    Kannengiesser, Stephan
    Arberet, Simon
    Othman, Ahmed E.
    Afat, Saif
    ACADEMIC RADIOLOGY, 2023, 30 (05) : 863 - 872
  • [35] Influence of echo time on pulmonary ventilation and perfusion derived by phase-resolved functional lung (PREFUL) MRI using multi-echo ultrashort echo time acquisition
    Behrendt, Lea
    Gutberlet, Marcel
    Voskrebenzev, Andreas
    Klimes, Filip
    Obert, Arnd J.
    Kern, Agilo L.
    Horstmann, Dominik
    Wernz, Marius M.
    Mueller, Robin A.
    Wacker, Frank
    Vogel-Claussen, Jens
    NMR IN BIOMEDICINE, 2024, 37 (12)
  • [36] SINGLE BREATH-HOLD MULTIECHO MRI SEQUENCES (AT 1.5T) FOR THE SIMULTANEOUS LIPID QUANTIFICATION AND T2*MEASUREMENT IN PATIENTS WITH INCREASED SERUM FERRITIN LEVELS
    Piperno, Alberto
    Trombini, Paola
    Redaelli, Irene
    Bernasconi, Davide Paolo
    Paruccini, Nicoletta
    Di Gennaro, Filiberto
    Pelucchi, Sara
    Zucchini, Nicola
    Bovo, Giorgio
    Galimberti, Stefania
    AMERICAN JOURNAL OF HEMATOLOGY, 2013, 88 (05) : E111 - E112
  • [37] Improved Single Breath-Hold SSFSE Sequence for Liver MRI Based on Compressed Sensing: Evaluation of Image Quality Compared with Conventional T2-Weighted Sequences
    Lee, Hyun Kyung
    Song, Ji Soo
    Jang, Weon
    Nickel, Dominik
    Paek, Mun Young
    DIAGNOSTICS, 2022, 12 (09)
  • [38] Single breath-hold 3D cardiac T1 mapping using through-time spiral GRAPPA
    Chen, Yong
    Lo, Wei-Ching
    Hamilton, Jesse I.
    Barkauskas, Kestutis
    Saybasili, Haris
    Wright, Katherine L.
    Batesole, Joshua
    Griswold, Mark A.
    Gulani, Vikas
    Seiberlich, Nicole
    NMR IN BIOMEDICINE, 2018, 31 (06)
  • [39] Fast breath-hold T2-weighted MRI of the kidney by means of half-Fourier single-shot turbo spin echo: Comparison with high resolution turbo spin echo sequence
    Nakayama, Y
    Yamashita, Y
    Matsuno, Y
    Tang, Y
    Namimoto, T
    Kadota, M
    Mitsuzaki, K
    Abe, Y
    Katahira, K
    Arakawa, A
    Takahashi, M
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (01) : 55 - 60
  • [40] Single breath-hold multiarterial dynamic MRI of the liver at 3T using a 3D fat-suppressed keyhole technique
    Hong, Hye-Suk
    Kim, Hua Sun
    Kim, Myeong-Jin
    De Becker, Jan
    Mitchell, Donald G.
    Kanematsu, Masayuki
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (02) : 396 - 402