Ready-made matrix-assisted laser desorption/ionization target plates coated with thin matrix layer for automated sample deposition in high-density array format

被引:41
|
作者
Miliotis, T
Kjellström, S
Nilsson, J
Laurell, T
Edholm, LE
Marko-Varga, G [1 ]
机构
[1] AstraZeneca R&D Lund, Mol Sci, SE-22187 Lund, Sweden
[2] Lund Univ, Dept Analyt Chem, SE-22100 Lund, Sweden
[3] Lund Inst Technol, Dept Elect Measurements, SE-22100 Lund, Sweden
关键词
D O I
10.1002/rcm.542
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The methodology for ready-made matrix-assisted laser desorption/ionization (MALDI) target plates covered with an optimized thin layer consisting of matrix and nitrocellulose has been developed. Piezoelectric microdispensing enabled sample depositions in a high-density array format of 2000 sample depositions on a conventionally sized target plate (45 x 47 mm.). The sample depositions were made reproducibly in a fully automated mode by using an in-house developed computer-controlled piezoelectric flow-through microdispenser. Additionally, the piezoelectric technique facilitated significant analyte enrichment that increased the detection sensitivity. The MS signal was obtained rapidly, generally within ten laser pulses. An airbrush device was used to generate a fine spray of matrix and nitrocellulose dissolved in acetone. The acetone evaporated instantly when reaching the target plate leaving the entire surface with a thin and uniform matrix/nitrocellulose coating consisting of very small crystals of matrix embedded in the nitrocellulose. These crystals acted as a seed-layer on subsequent analyte depositions, rendering homogeneous sample spots when using alpha-cyano-4-hydroxycinnamic acid (CHCA) as matrix. The relative standard deviation of the signal intensity between spots was (20-30)% (n = 30). The detection sensitivity was improved by restricting the sample spot diameter to 300 mum. The spot size was affected by the deposition rate and the evaporation rate of the dispensed sample volume. Mass spectra of a 25-amol peptide mixture deposition were successfully recorded. Copyright (C) 2001 John Wiley Sons, Ltd.
引用
收藏
页码:117 / 126
页数:10
相关论文
共 50 条
  • [31] A solid-phase bioreactor with continuous sample deposition for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    Lee, Jeonghoon
    Soper, Steven A.
    Murray, Kermit K.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (06) : 693 - 699
  • [32] Electrospray sample deposition for matrix-assisted laser desorption/ionization (MALDI) and atmospheric pressure MALDI mass spectrometry with attomole detection limits
    Wei, H
    Nolkrantz, K
    Powell, DH
    Woods, JH
    Ko, MC
    Kennedy, RT
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (11) : 1193 - 1200
  • [33] Analysis of native milk oligosaccharides directly from thin-layer chromatography plates by matrix-assisted laser desorption/ionization orthogonal-time-of-flight mass spectrometry with a glycerol matrix
    Dreisewerd, K
    Kölbl, S
    Peter-Katalinic, J
    Berkenkamp, S
    Pohlentz, G
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (02) : 139 - 150
  • [34] Analysis of native milk oligosaccharides directly from thin-layer chromatography plates by matrix-assisted laser desorption/ionization orthogonal-time-of-flight mass spectrometry with a glycerol matrix
    Dreisewerd, Klaus
    Kölbl, Stefanie
    Peter-Katalinić, Jasna
    Berkenkamp, Stefan
    Pohlentz, Gottfried
    Journal of the American Society for Mass Spectrometry, 2006, 17 (02): : 139 - 150
  • [35] Polyethlene membrane as a sample support for direct matrix-assisted laser desorption/ionization mass spectrometric analysis of high mass proteins
    Blackledge, J.A.
    Alexander, A.J.
    Analytical Chemistry, 1995, 67 (05)
  • [36] Capillary isoelectric focusing hyphenated to single- and multistage matrix-assisted laser desorption/ionization-mass spectrometry using automated sheath-flow-assisted sample deposition
    Lechner, Michael
    Seifner, Alexandra
    Rizzi, Andreas M.
    ELECTROPHORESIS, 2008, 29 (10) : 1974 - 1984
  • [37] Analysis of organic reactions by thin layer chromatography combined with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    St Hilaire, PM
    Cipolla, L
    Tedebark, U
    Meldal, M
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1998, 12 (20) : 1475 - 1484
  • [38] Ganglioside analysis by thin-layer chromatography matrix-assisted laser desorption/ionization orthogonal time-of-flight mass spectrometry
    Ivleva, VB
    Sapp, LM
    O'Connor, PB
    Costello, CE
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2005, 16 (09) : 1552 - 1560
  • [39] Stationary phase thickness determines the quality of thin-layer chromatography/matrix-assisted laser desorption and ionization mass spectra of lipids
    Griesinger, Hans
    Fuchs, Beate
    Suess, Rosmarie
    Matheis, Katerina
    Schulz, Michael
    Schiller, Juergen
    ANALYTICAL BIOCHEMISTRY, 2014, 451 : 45 - 47
  • [40] High-Throughput Fingerprinting of Rhizobial Free Fatty Acids by Chemical Thin-Film Deposition and Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry
    Gladchuk, Aleksey
    Shumilina, Julia
    Kusnetsova, Alena
    Bureiko, Ksenia
    Billig, Susan
    Tsarev, Alexander
    Alexandrova, Irina
    Leonova, Larisa
    Zhukov, Vladimir A.
    Tikhonovich, Igor A.
    Birkemeyer, Claudia
    Podolskaya, Ekaterina
    Frolov, Andrej
    METHODS AND PROTOCOLS, 2020, 3 (02) : 1 - 17